Cervical carotid plaque evaluation using 3D T1-weighted black-blood magnetic resonance imaging: Comparison of turbo field-echo and turbo spin-echo sequences

被引:4
|
作者
Inoue, Katsuhiro [1 ]
Maeda, Masayuki [2 ]
Umino, Maki [3 ]
Takase, Shinichi [1 ]
Yamahata, Tsunehiro [1 ]
Sakuma, Hajime [3 ]
机构
[1] Mie Univ Hosp, Dept Radiol, Tsu, Mie, Japan
[2] Mie Univ, Sch Med, Dept Adv Diagnost Imaging, 2-174 Edobashi, Tsu, Mie 5148507, Japan
[3] Mie Univ, Sch Med, Depatment Radiol, Tsu, Mie 5148507, Japan
基金
日本学术振兴会;
关键词
Carotid plaque; Magnetic resonance imaging; Black blood; 3D imaging; INTRAPLAQUE HEMORRHAGE; RISK; PROGRESSION; DISEASE; MRI;
D O I
10.1016/j.ejrad.2016.03.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the capability of three-dimensional (3D) T1-weighted turbo field -echo (TFE) black blood (BB) magnetic resonance imaging (MRI) and turbo-spin echo (TSE) BB MRI for discerning carotid plaques and the difference of signal intensities of the plaques from that of adjacent muscle in patients with cervical carotid stenosis. Methods: Cervical carotid stenosis was evaluated by 3.0-T MR in 43 patients (38 men and 5 women; age, 36-83 years; mean age, 70 years) during 8 months. The carotid BB MRI comprised 3D T1-weighted TSE BB (T1-TSEBB) and 3D T1-weighted TFE BB (T1-TFEBB) sequences. The delineation of the carotid plaque border was evaluated in comparison with digital subtraction angiography (DSA). The border between the plaque and vessel lumen was rated visually (4-point analysis) and quantitatively (contrast-to-noise ratio). The signal-intensity ratio (SIR) of the plaque to the adjacent muscle was also measured. Data of 3D T1 -TSEBB and 3D T1-TFEBB were compared statistically using the Wilcoxon signed-rank test. Results: Visual and quantitative analyses revealed that the border between the plaque and vessel lumen was better delineated on 3D T1 -TSEBB MRI than on 3D T1-TFEBB MRI (p < 0.01, respectively). SIR of the plaque-to-adjacent muscle was higher on 3D T1-TFEBB MRI than on 3D T1 -TSEBB MRI (p < 0.05). High signal plaques with a SIR of >1.5 were underestimated on 3D T1 -TSEBB MRI. Conclusions: 3D Tl-TSEBB MRI was superior to 3D Tl-TFEBB MRI for delineating carotid plaques; however, high signal plaques were underestimated on 3D T1 -TSEBB MRI. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1035 / 1039
页数:5
相关论文
共 50 条
  • [21] Optimized T1-weighted contrast for single-slab 3D turbo spin-echo imaging with long echo trains:: Application to whole-brain imaging
    Park, Jaeseok
    Mugler, John P., III
    Horger, Wilhelm
    Kiefer, Berthold
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) : 982 - 992
  • [22] Black blood MR angiography using multislab three-dimensional T1-weighted turbo spin-echo technique: Imaging of intracranial circulation
    Melhem, ER
    Jara, H
    Yucel, EK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (05) : 1418 - 1420
  • [23] High-resolution magnetic resonance imaging of intracranial vessel walls: Comparison of 3D T1-weighted turbo spin echo with or without DANTE or iMSDE
    Cho, Se Jin
    Jung, Seung Chai
    Suh, Chong Hyun
    Lee, Jung Bin
    Kim, Donghyun
    PLOS ONE, 2019, 14 (08):
  • [24] High-resolution magnetic resonance imaging of intracranial vessel walls: Comparison of 3D T1-weighted turbo spin echo with or without DANTE or iMSDE
    Cho, S. J.
    Jung, S. C.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2019, 405
  • [25] Contrast enhancement sources on post-Gadolinium "black-blood" 3D T1-weighted Turbo -Spin -Echo images in patients with multiple sclerosis.
    Gobbi, Claudio
    Danieli, Lucia
    Distefano, Daniela
    Cianfoni, Alessandro
    Roccatagliata, Luca
    Pravata, Emanuele
    Zecca, Chiara
    NEUROLOGY, 2022, 98 (18)
  • [26] Comparison of ultrafast half-Fourier single-shot turbo spin-echo sequence with turbo spin-echo sequences for T2-weighted imaging of the female pelvis
    Yamashita, Y
    Tang, Y
    Abe, Y
    Mitsuzaki, K
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06): : 1207 - 1212
  • [27] Compressed SENSE accelerated 3D T1w black blood turbo spin echo versus 2D T1w turbo spin echo sequence in pituitary magnetic resonance imaging
    Sartoretti, Thomas
    Sartoretti, Elisabeth
    Wyss, Michael
    Schwenk, Arpad
    van Smoorenburg, Luuk
    Eichenberger, Barbara
    Najafi, Arash
    Binkert, Christoph
    Becker, Anton S.
    Sartoretti-Schefer, Sabine
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 120
  • [28] Liver T2-weighted MR imaging: Comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences
    Tang, Y
    Yamashita, Y
    Namimoto, T
    Abe, Y
    Takahashi, M
    RADIOLOGY, 1997, 203 (03) : 766 - 772
  • [29] Application of T1-weighted BLADE sequence to abdominal magnetic resonance imaging of young children: a comparison with turbo spin echo sequence
    Choi, Kyu Sung
    Choi, Young Hun
    Cheon, Jung-Eun
    Kim, Woo Sun
    Kim, In One
    ACTA RADIOLOGICA, 2020, 61 (10) : 1406 - 1413
  • [30] Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient-Echo Sequence for Contrast-Enhanced Pediatric Spinal Imaging: Comparison With T1-Weighted Turbo Spin-Echo Sequence
    Cho, Hyun-Hae
    Choi, Young Hun
    Cheon, Jung-Eun
    Lee, So Mi
    Kim, Woo Sun
    Kim, In-One
    Paek, MunYoung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 177 - 182