Cervical carotid plaque evaluation using 3D T1-weighted black-blood magnetic resonance imaging: Comparison of turbo field-echo and turbo spin-echo sequences

被引:4
|
作者
Inoue, Katsuhiro [1 ]
Maeda, Masayuki [2 ]
Umino, Maki [3 ]
Takase, Shinichi [1 ]
Yamahata, Tsunehiro [1 ]
Sakuma, Hajime [3 ]
机构
[1] Mie Univ Hosp, Dept Radiol, Tsu, Mie, Japan
[2] Mie Univ, Sch Med, Dept Adv Diagnost Imaging, 2-174 Edobashi, Tsu, Mie 5148507, Japan
[3] Mie Univ, Sch Med, Depatment Radiol, Tsu, Mie 5148507, Japan
基金
日本学术振兴会;
关键词
Carotid plaque; Magnetic resonance imaging; Black blood; 3D imaging; INTRAPLAQUE HEMORRHAGE; RISK; PROGRESSION; DISEASE; MRI;
D O I
10.1016/j.ejrad.2016.03.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the capability of three-dimensional (3D) T1-weighted turbo field -echo (TFE) black blood (BB) magnetic resonance imaging (MRI) and turbo-spin echo (TSE) BB MRI for discerning carotid plaques and the difference of signal intensities of the plaques from that of adjacent muscle in patients with cervical carotid stenosis. Methods: Cervical carotid stenosis was evaluated by 3.0-T MR in 43 patients (38 men and 5 women; age, 36-83 years; mean age, 70 years) during 8 months. The carotid BB MRI comprised 3D T1-weighted TSE BB (T1-TSEBB) and 3D T1-weighted TFE BB (T1-TFEBB) sequences. The delineation of the carotid plaque border was evaluated in comparison with digital subtraction angiography (DSA). The border between the plaque and vessel lumen was rated visually (4-point analysis) and quantitatively (contrast-to-noise ratio). The signal-intensity ratio (SIR) of the plaque to the adjacent muscle was also measured. Data of 3D T1 -TSEBB and 3D T1-TFEBB were compared statistically using the Wilcoxon signed-rank test. Results: Visual and quantitative analyses revealed that the border between the plaque and vessel lumen was better delineated on 3D T1 -TSEBB MRI than on 3D T1-TFEBB MRI (p < 0.01, respectively). SIR of the plaque-to-adjacent muscle was higher on 3D T1-TFEBB MRI than on 3D T1 -TSEBB MRI (p < 0.05). High signal plaques with a SIR of >1.5 were underestimated on 3D T1 -TSEBB MRI. Conclusions: 3D Tl-TSEBB MRI was superior to 3D Tl-TFEBB MRI for delineating carotid plaques; however, high signal plaques were underestimated on 3D T1 -TSEBB MRI. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1035 / 1039
页数:5
相关论文
共 50 条
  • [31] Identification of the Distal End of Carotid Plaque Using 3-Dimensional Fast Spin Echo T1-Weighted Magnetic Resonance Plaque Imaging
    Chida, Kohei
    Shimada, Yasuyoshi
    Fujimoto, Kentaro
    Yoshida, Jun
    Kojima, Daigo
    Fujiwara, Shunrou
    Kobayashi, Masakazu
    Yoshida, Kenji
    Sasaki, Makoto
    Ogasawara, Kuniaki
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2020, 29 (04):
  • [32] Characterization of lenticulostriate arteries with high resolution black-blood T1-weighted turbo spin echo with variable flip angles at 3 and 7 Tesla
    Ma, Samantha J.
    Sarabi, Mona Sharifi
    Yan, Lirong
    Shao, Xingfeng
    Chen, Yue
    Yang, Qi
    Jann, Kay
    Toga, Arthur W.
    Shi, Yonggang
    Wang, Danny J. J.
    NEUROIMAGE, 2019, 199 : 184 - 193
  • [33] 3D fat-suppressed T1-weighted volume isotropic turbo spin-echo acquisition (VISTA) imaging for the evaluation of the ectopic posterior pituitary gland
    Azuma, Minako
    Kadota, Yoshihito
    Matsuyama, Misayo
    Moritake, Hiroshi
    Hirai, Toshinori
    JAPANESE JOURNAL OF RADIOLOGY, 2021, 39 (06) : 564 - 570
  • [34] 3D fat-suppressed T1-weighted volume isotropic turbo spin-echo acquisition (VISTA) imaging for the evaluation of the ectopic posterior pituitary gland
    Minako Azuma
    Yoshihito Kadota
    Misayo Matsuyama
    Hiroshi Moritake
    Toshinori Hirai
    Japanese Journal of Radiology, 2021, 39 : 564 - 570
  • [35] Detection and characterization of focal hepatic lesions by T2-weighted imaging: comparison of navigator-triggered turbo spin-echo, breath-hold turbo spin-echo, and HASTE sequences
    Lee, Ho Yun
    Lee, Jeong Min
    Kim, Se Hyung
    Shin, Kyung Sook
    Lee, Jae Young
    Han, Joon Koo
    Choi, Byung Ihn
    CLINICAL IMAGING, 2009, 33 (04) : 281 - 288
  • [36] Carotid MRA – what advantages do the turbo field-echo and 3D phase-contrast sequences offer?
    M. S. Benjamin
    A. R. Gillams
    A. P. Carter
    Neuroradiology, 1997, 39 : 469 - 473
  • [37] Evaluation of the Canine Intervertebral Disc Structure in Turbo Spin Echo-T2 and Fast Field Echo-T1 Sequences in Magnetic Resonance Imaging
    Kunze, Katarina
    Stein, Veronika Maria
    Tipold, Andrea
    FRONTIERS IN VETERINARY SCIENCE, 2019, 6
  • [38] Carotid MRA - What advantages do the turbo field-echo and 3D phase-contrast sequences offer?
    Benjamin, MS
    Gillams, AR
    Carter, AP
    NEURORADIOLOGY, 1997, 39 (07) : 469 - 473
  • [39] Evaluation of the Subscapularis Tendon Tears on 3T Magnetic Resonance Arthrography: Comparison of Diagnostic Performance of T1-Weighted Spectral Presaturation with Inversion-Recovery and T2-Weighted Turbo Spin-Echo Sequences
    Lee, Hoseok
    Ahn, Joong Mo
    Kang, Yusuhn
    Oh, Joo Han
    Lee, Eugene
    Lee, Joon Woo
    Kang, Heung Sik
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (02) : 320 - 327
  • [40] Comparison of spin echo T1-weighted sequences versus fast spin-echo proton density-weighted sequences for evaluation of meniscal tears at 1.5 T
    Wolff, Andrew B.
    Pesce, Lorenzo L.
    Wu, Jim S.
    Smart, L. Ryan
    Medvecky, Michael J.
    Haims, Andrew H.
    SKELETAL RADIOLOGY, 2009, 38 (01) : 21 - 29