Implant Platform Switching: Biomechanical Approach Using Two-Dimensional Finite Element Analysis

被引:28
|
作者
Tabata, Lucas Fernando [1 ]
Assuncao, Wirley Goncalves [1 ]
Ricardo Barao, Valentim Adelino [1 ]
Capello de Sousa, Edson Antonio [2 ]
Gomes, Erica Alves [1 ]
Delben, Juliana Aparecida [1 ]
机构
[1] Univ Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 Sao Paulo, Brazil
[2] Univ Estadual Paulista, Bauru Engn Sch, Dept Mech Engn, BR-16015050 Sao Paulo, Brazil
基金
英国惠康基金; 美国国家卫生研究院;
关键词
Dental implants; platform switching; implant supported prosthesis; finite element analysis; stress distribution; crestal bone loss; TITANIUM IMPLANTS; OSSEOINTEGRATED IMPLANTS; FIXED PROSTHESES; MARGINAL BONE; CRESTAL BONE; STRESS-DISTRIBUTION; BIOLOGIC WIDTH; ORAL IMPLANTS; IN-VIVO; DOG;
D O I
10.1097/SCS.0b013e3181c50eb8
中图分类号
R61 [外科手术学];
学科分类号
摘要
In implant therapy, a peri-implant bone resorption has been noticed mainly in the first year after prosthesis insertion. This bone remodeling can sometimes jeopardize the outcome of the treatment, especially in areas in which short implants are used and also in aesthetic cases. To avoid this occurrence, the use of platform switching (PS) has been used. This study aimed to evaluate the biomechanical concept of PS with relation to stress distribution using two-dimensional finite element analysis. A regular matching diameter connection of abutment-implant (regular platform group [RPG]) and a PS connection (PS group [PSG]) were simulated by 2 two-dimensional finite element models that reproduced a 2-piece implant system with peri-implant bone tissue. A regular implant (prosthetic platform of 4.1 mm) and a wide implant (prosthetic platform of 5.0 mm) were used to represent the RPG and PSG, respectively, in which a regular prosthetic component of 4.1 mm was connected to represent the crown. A load of 100 N was applied on the models using ANSYS software. The RPG spreads the stress over a wider area in the peri-implant bone tissue (159 MPa) and the implant (1610 MPa), whereas the PSG seems to diminish the stress distribution on bone tissue (34 MPa) and implant (649 MPa). Within the limitation of the study, the PS presented better biomechanical behavior in relation to stress distribution on the implant but especially in the bone tissue (80% less). However, in the crown and retention screw, an increase in stress concentration was observed.
引用
收藏
页码:182 / 187
页数:6
相关论文
共 50 条
  • [41] TWO-DIMENSIONAL HYSTERESIS MODEL USING FINITE-ELEMENT METHOD
    FELIACHI, M
    MEUNIER, G
    IEEE TRANSACTIONS ON MAGNETICS, 1985, 21 (06) : 2362 - 2365
  • [42] A solution of two-dimensional magnetohydrodynamic flow using the Finite Element Method
    Verardi, SLL
    Cardoso, JR
    Motta, CC
    IEEE TRANSACTIONS ON MAGNETICS, 1998, 34 (05) : 3134 - 3137
  • [43] Modelling of two-dimensional laminar flow using finite element method
    Jurjevic, R
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 1999, 31 (03) : 601 - 626
  • [44] Two-dimensional modeling of complex resistivity using finite element method
    Cai Jun-Tao
    Ruan Bai-Yao
    Zhao Guo-Ze
    Zhu Guang-Ping
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2007, 50 (06): : 1869 - 1876
  • [45] TWO-DIMENSIONAL PROCESS MODELING USING THE FINITE-ELEMENT METHOD
    HANSEN, HH
    SALSBURG, K
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1982, 129 (08) : C327 - C327
  • [46] Two-dimensional finite-element analysis of tapered segmented structures
    Noriega, Ruth Rubio
    Hernandez-Figuero, Hugo
    INTEGRATED OPTICS: DEVICES, MATERIALS, AND TECHNOLOGIES XVII, 2013, 8627
  • [47] Two-dimensional finite element analysis of the stability of Ag/BSCCO tapes
    Burkhardt, EE
    Schwartz, J
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 41, PTS A AND B, 1996, : 545 - 552
  • [48] Finite element formulation for two-dimensional inverse heat conduction analysis
    Hsu, T.R.
    Sun, N.S.
    Chen, G.G.
    Gong, Z.L.
    Journal of Heat Transfer, 1992, 114 (03): : 553 - 557
  • [50] Biomechanical assessment of a novel L4/5 level interspinous implant using three dimensional finite element analysis
    Song, C.
    Li, X. -F.
    Liu, Z. -D.
    Zhong, G. -B.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2014, 18 (01) : 86 - 94