Implant Platform Switching: Biomechanical Approach Using Two-Dimensional Finite Element Analysis

被引:28
|
作者
Tabata, Lucas Fernando [1 ]
Assuncao, Wirley Goncalves [1 ]
Ricardo Barao, Valentim Adelino [1 ]
Capello de Sousa, Edson Antonio [2 ]
Gomes, Erica Alves [1 ]
Delben, Juliana Aparecida [1 ]
机构
[1] Univ Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 Sao Paulo, Brazil
[2] Univ Estadual Paulista, Bauru Engn Sch, Dept Mech Engn, BR-16015050 Sao Paulo, Brazil
基金
英国惠康基金; 美国国家卫生研究院;
关键词
Dental implants; platform switching; implant supported prosthesis; finite element analysis; stress distribution; crestal bone loss; TITANIUM IMPLANTS; OSSEOINTEGRATED IMPLANTS; FIXED PROSTHESES; MARGINAL BONE; CRESTAL BONE; STRESS-DISTRIBUTION; BIOLOGIC WIDTH; ORAL IMPLANTS; IN-VIVO; DOG;
D O I
10.1097/SCS.0b013e3181c50eb8
中图分类号
R61 [外科手术学];
学科分类号
摘要
In implant therapy, a peri-implant bone resorption has been noticed mainly in the first year after prosthesis insertion. This bone remodeling can sometimes jeopardize the outcome of the treatment, especially in areas in which short implants are used and also in aesthetic cases. To avoid this occurrence, the use of platform switching (PS) has been used. This study aimed to evaluate the biomechanical concept of PS with relation to stress distribution using two-dimensional finite element analysis. A regular matching diameter connection of abutment-implant (regular platform group [RPG]) and a PS connection (PS group [PSG]) were simulated by 2 two-dimensional finite element models that reproduced a 2-piece implant system with peri-implant bone tissue. A regular implant (prosthetic platform of 4.1 mm) and a wide implant (prosthetic platform of 5.0 mm) were used to represent the RPG and PSG, respectively, in which a regular prosthetic component of 4.1 mm was connected to represent the crown. A load of 100 N was applied on the models using ANSYS software. The RPG spreads the stress over a wider area in the peri-implant bone tissue (159 MPa) and the implant (1610 MPa), whereas the PSG seems to diminish the stress distribution on bone tissue (34 MPa) and implant (649 MPa). Within the limitation of the study, the PS presented better biomechanical behavior in relation to stress distribution on the implant but especially in the bone tissue (80% less). However, in the crown and retention screw, an increase in stress concentration was observed.
引用
收藏
页码:182 / 187
页数:6
相关论文
共 50 条
  • [21] A rolling process two-dimensional finite element model analysis
    Lin, ZC
    Shen, CC
    FINITE ELEMENTS IN ANALYSIS AND DESIGN, 1997, 26 (02) : 143 - 160
  • [22] Two-Dimensional finite element analysis of laboratory embankment model
    Ahmed, A.
    El-Tohami, A. M. K.
    Marei, N. A.
    GEOTECHNICAL ENGINEERING FOR DISASTER MITIGATION AND REHABILITATION, 2008, : 1003 - +
  • [23] Finite Element Analysis to Two-Dimensional Nonlinear Sloshing Problems
    严承华
    王赤忠
    程尔升
    China Ocean Engineering, 2001, (02) : 291 - 300
  • [24] Two-dimensional sketch-based finite element analysis
    Phair, ME
    Hutchinson, TC
    Kuester, F
    Proceedings of the Fifteenth IASTED International Conference on Modelling and Simulation, 2004, : 135 - 140
  • [25] Finite element analysis to two-dimensional nonlinear sloshing problems
    Yan, CH
    Wang, CZ
    Cheng, ES
    CHINA OCEAN ENGINEERING, 2001, 15 (02) : 291 - 300
  • [26] A two-dimensional finite-element analysis of reverberation chambers
    Bunting, CF
    Moeller, KJ
    Reddy, CJ
    Scearce, SA
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1999, 41 (04) : 280 - 289
  • [27] TWO-DIMENSIONAL FINITE ELEMENT ANALYSIS OF LABORATORY SEAWALL MODEL
    Zhang Jian
    Zhai Jian-feng
    Wang Xian-Mei
    Chen Jie
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING IV, 2014, 580-583 : 2134 - +
  • [28] Two-Dimensional Equivalent Models in the Analysis of a Multibody Elastic System Using the Finite Element Analysis
    Scutaru, Maria Luminita
    Vlase, Sorin
    MATHEMATICS, 2023, 11 (19)
  • [29] Design Analysis of Miniature Quartz Resonator Using Two-Dimensional Finite Element Model
    Huang, Zi-Gui
    Chen, Zheng-Yu
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (06) : 1145 - 1154
  • [30] Boundary element analysis of bar silencers using the scattering matrix with two-dimensional finite element modes
    Yang, L.
    Wang, P.
    Wu, T. W.
    ENGINEERING ANALYSIS WITH BOUNDARY ELEMENTS, 2017, 74 : 100 - 106