Implant Platform Switching: Biomechanical Approach Using Two-Dimensional Finite Element Analysis

被引:28
|
作者
Tabata, Lucas Fernando [1 ]
Assuncao, Wirley Goncalves [1 ]
Ricardo Barao, Valentim Adelino [1 ]
Capello de Sousa, Edson Antonio [2 ]
Gomes, Erica Alves [1 ]
Delben, Juliana Aparecida [1 ]
机构
[1] Univ Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 Sao Paulo, Brazil
[2] Univ Estadual Paulista, Bauru Engn Sch, Dept Mech Engn, BR-16015050 Sao Paulo, Brazil
基金
英国惠康基金; 美国国家卫生研究院;
关键词
Dental implants; platform switching; implant supported prosthesis; finite element analysis; stress distribution; crestal bone loss; TITANIUM IMPLANTS; OSSEOINTEGRATED IMPLANTS; FIXED PROSTHESES; MARGINAL BONE; CRESTAL BONE; STRESS-DISTRIBUTION; BIOLOGIC WIDTH; ORAL IMPLANTS; IN-VIVO; DOG;
D O I
10.1097/SCS.0b013e3181c50eb8
中图分类号
R61 [外科手术学];
学科分类号
摘要
In implant therapy, a peri-implant bone resorption has been noticed mainly in the first year after prosthesis insertion. This bone remodeling can sometimes jeopardize the outcome of the treatment, especially in areas in which short implants are used and also in aesthetic cases. To avoid this occurrence, the use of platform switching (PS) has been used. This study aimed to evaluate the biomechanical concept of PS with relation to stress distribution using two-dimensional finite element analysis. A regular matching diameter connection of abutment-implant (regular platform group [RPG]) and a PS connection (PS group [PSG]) were simulated by 2 two-dimensional finite element models that reproduced a 2-piece implant system with peri-implant bone tissue. A regular implant (prosthetic platform of 4.1 mm) and a wide implant (prosthetic platform of 5.0 mm) were used to represent the RPG and PSG, respectively, in which a regular prosthetic component of 4.1 mm was connected to represent the crown. A load of 100 N was applied on the models using ANSYS software. The RPG spreads the stress over a wider area in the peri-implant bone tissue (159 MPa) and the implant (1610 MPa), whereas the PSG seems to diminish the stress distribution on bone tissue (34 MPa) and implant (649 MPa). Within the limitation of the study, the PS presented better biomechanical behavior in relation to stress distribution on the implant but especially in the bone tissue (80% less). However, in the crown and retention screw, an increase in stress concentration was observed.
引用
收藏
页码:182 / 187
页数:6
相关论文
共 50 条
  • [31] Modal analysis of two-dimensional beams using parallel finite-element method
    Heydari, S.
    Gharebaghi, S. Asil
    SCIENTIA IRANICA, 2017, 24 (06) : 2762 - 2775
  • [32] Validation of a nonlinear two-dimensional interface element for finite-element analysis
    Vaillancourt, H
    McCammond, D
    Pilliar, RM
    EXPERIMENTAL MECHANICS, 1996, 36 (01) : 49 - 54
  • [33] Analysis of two-dimensional acoustic radiation problems using the finite element with cover functions
    Gui, Qiang
    Zhou, You
    Li, Wei
    Chai, Yingbin
    APPLIED ACOUSTICS, 2022, 185
  • [34] Effect of Passive Fit Absence in the Prosthesis/Implant/Retaining Screw System: A Two-Dimensional Finite Element Analysis
    Gomes, Erica Alves
    Assuncao, Wirley Goncalves
    Tabata, Lucas Fernando
    Ricardo Barao, Valentim Adelino
    Delben, Juliana Aparecida
    Capello de Sousa, Edson Antonio
    JOURNAL OF CRANIOFACIAL SURGERY, 2009, 20 (06) : 2000 - 2005
  • [35] A two-dimensional ideal gas finite element
    Schmidt, RJ
    Fulton, KR
    FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2001, 37 (08) : 621 - 637
  • [36] Effect of platform switching on peri-implant bone: A 3D finite element analysis
    Aslam, Ayesha
    Hassan, Syed Hammad
    Aslam, Hammad Mudasser
    Khan, Danish Azeem
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (06): : 935 - 940
  • [37] Selection of the implant thread pitch for optimal biomechanical properties: A three-dimensional finite element analysis
    Kong, Liang
    Zhao, Yunzhuan
    Hu, Kaijin
    Li, Dehua
    Zhou, Hongzhi
    Wu, Ziyan
    Liu, Baolin
    ADVANCES IN ENGINEERING SOFTWARE, 2009, 40 (07) : 474 - 478
  • [38] Biomechanical optimization of the diameter of distraction screw in distraction implant by three-dimensional finite element analysis
    Lu, Songhe
    Li, Tao
    Zhang, Yongqiang
    Lu, Chunlei
    Sun, Yingying
    Zhang, Junrui
    Xu, Dezhong
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (11) : 1949 - 1954
  • [39] Selection of the implant transgingival height for optimal biomechanical properties: a three-dimensional finite element analysis
    Sun, Yingying
    Kong, Liang
    Hu, Kaijin
    Xie, Cheng
    Zhou, Hongzhi
    Liu, Yanpu
    Liu, Baolin
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2009, 47 (05): : 393 - 398
  • [40] Selection of the distraction implant length with improved biomechanical properties by three-dimensional finite element analysis
    Gao, J.
    Li, T.
    Hou, X. -C.
    Wang, Z.
    Kong, L.
    Chen, J. -H.
    JOURNAL OF ORAL REHABILITATION, 2011, 38 (04) : 270 - 277