Implant Platform Switching: Biomechanical Approach Using Two-Dimensional Finite Element Analysis

被引:28
|
作者
Tabata, Lucas Fernando [1 ]
Assuncao, Wirley Goncalves [1 ]
Ricardo Barao, Valentim Adelino [1 ]
Capello de Sousa, Edson Antonio [2 ]
Gomes, Erica Alves [1 ]
Delben, Juliana Aparecida [1 ]
机构
[1] Univ Estadual Paulista, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, BR-16015050 Sao Paulo, Brazil
[2] Univ Estadual Paulista, Bauru Engn Sch, Dept Mech Engn, BR-16015050 Sao Paulo, Brazil
基金
英国惠康基金; 美国国家卫生研究院;
关键词
Dental implants; platform switching; implant supported prosthesis; finite element analysis; stress distribution; crestal bone loss; TITANIUM IMPLANTS; OSSEOINTEGRATED IMPLANTS; FIXED PROSTHESES; MARGINAL BONE; CRESTAL BONE; STRESS-DISTRIBUTION; BIOLOGIC WIDTH; ORAL IMPLANTS; IN-VIVO; DOG;
D O I
10.1097/SCS.0b013e3181c50eb8
中图分类号
R61 [外科手术学];
学科分类号
摘要
In implant therapy, a peri-implant bone resorption has been noticed mainly in the first year after prosthesis insertion. This bone remodeling can sometimes jeopardize the outcome of the treatment, especially in areas in which short implants are used and also in aesthetic cases. To avoid this occurrence, the use of platform switching (PS) has been used. This study aimed to evaluate the biomechanical concept of PS with relation to stress distribution using two-dimensional finite element analysis. A regular matching diameter connection of abutment-implant (regular platform group [RPG]) and a PS connection (PS group [PSG]) were simulated by 2 two-dimensional finite element models that reproduced a 2-piece implant system with peri-implant bone tissue. A regular implant (prosthetic platform of 4.1 mm) and a wide implant (prosthetic platform of 5.0 mm) were used to represent the RPG and PSG, respectively, in which a regular prosthetic component of 4.1 mm was connected to represent the crown. A load of 100 N was applied on the models using ANSYS software. The RPG spreads the stress over a wider area in the peri-implant bone tissue (159 MPa) and the implant (1610 MPa), whereas the PSG seems to diminish the stress distribution on bone tissue (34 MPa) and implant (649 MPa). Within the limitation of the study, the PS presented better biomechanical behavior in relation to stress distribution on the implant but especially in the bone tissue (80% less). However, in the crown and retention screw, an increase in stress concentration was observed.
引用
收藏
页码:182 / 187
页数:6
相关论文
共 50 条
  • [1] Biomechanical Effect of Platform Switching in Implant Dentistry: A Three-Dimensional Finite Element Analysis
    Chang, Chih-Ling
    Chen, Chen-Sheng
    Hsu, Ming-Lun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (02) : 295 - 304
  • [2] Platform Switching: Biomechanical Evaluation Using Three-Dimensional Finite Element Analysis
    Tabata, Lucas Fernando
    Rocha, Eduardo Passos
    Ricardo Barao, Valentim Adelino
    Assuncao, Wirley Goncalves
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (03) : 482 - 491
  • [3] Biomechanical Evaluation of Platform Switching in Different Implant Protocols: Computed Tomography-Based Three-Dimensional Finite Element Analysis
    Pessoa, Roberto S.
    Vaz, Luis Geraldo
    Marcantonio, Elcio, Jr.
    Vander Sloten, Jos
    Duyck, Joke
    Jaecques, Siegfried V. N.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (05) : 911 - 919
  • [4] The influence of platform switching on the biomechanical aspects of the implant-abutment system. A three dimensional finite element study
    Canullo, Luigi
    Pace, Francesco
    Coelho, Paulo
    Sciubba, Enrico
    Vozza, Iole
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2011, 16 (06): : E852 - E856
  • [5] Two-dimensional biomechanical finite element modeling of the pelvic floor and prolapse
    Xue, Xianglu
    Wang, Haifeng
    Xie, Jiachen
    Gao, Zhenhua
    Shen, Jihong
    Yao, Tingqiang
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2023, 22 (04) : 1425 - 1446
  • [6] Two-dimensional biomechanical finite element modeling of the pelvic floor and prolapse
    Xianglu Xue
    Haifeng Wang
    Jiachen Xie
    Zhenhua Gao
    Jihong Shen
    Tingqiang Yao
    Biomechanics and Modeling in Mechanobiology, 2023, 22 : 1425 - 1446
  • [7] Three-dimensional finite element analysis of platform switched implant
    Moon, Se-Young
    Lim, Young-Jun
    Kim, Myung-Joo
    Kwon, Ho-Beom
    JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (01): : 31 - 37
  • [8] Effect of Platform Switching on Implant Crest Bone Stress: A Finite Element Analysis
    Schrotenboer, Jason
    Tsao, Yi-Pin
    Kinariwala, Vipul
    Wang, Hom-Lay
    IMPLANT DENTISTRY, 2009, 18 (03) : 260 - 265
  • [9] Biomechanical Simulation of a Dental Implant using Finite Element Method Analysis
    Costa, D. C.
    Belinha, J.
    Natal Jorge, R. M.
    2019 6TH IEEE PORTUGUESE MEETING IN BIOENGINEERING (ENBENG), 2019,
  • [10] BIOMECHANICAL ANALYSIS OF THE INTERVERTEBRAL DISC IMPLANT USING THE FINITE ELEMENT METHOD
    Kajzer, W.
    Kajzer, A.
    Pindycki, I.
    ADVANCES IN MATERIALS SCIENCE, 2015, 15 (03): : 57 - 66