Enumeration of antigen-specific CD8+ T lymphocytes by single-platform, HLA tetramer-based flow cytometry:: A European multicenter evaluation

被引:20
|
作者
Heijnen, IAFM [1 ]
Barnett, D
Arroz, MJ
Barry, SM
Bonneville, M
Brando, B
D'hautcourt, JL
Kern, F
Tötterman, TH
Marijt, EWA
Bossy, D
Preijers, FWMB
Rothe, G
Gratama, JW
机构
[1] Kantonsspital Aarau, Dept Lab Med, Div Immunol, CH-5001 Aarau, Switzerland
[2] Royal Hallamshire Hosp, Dept Hematol, Sheffield, S Yorkshire, England
[3] Hosp Egas Moniz SA, Flow Cytometry Unit, Lisbon, Portugal
[4] Royal Free Hosp, Dept Clin Immunol, London, England
[5] Inst Biol, INSERM Unite 463, Nantes, France
[6] Osped Niguarda Ca Granda, Transplant Immunol & Hematol Lab, Milan, Italy
[7] Hop Warquignies, Lab Cytometr, Boussu, Belgium
[8] Univ Hosp Charite, Inst Med Immunol, Berlin, Germany
[9] Univ Uppsala Hosp, Dept Clin Immunol, Uppsala, Sweden
[10] Leiden Univ, Med Ctr, Dept Hematol, Leiden, Netherlands
[11] Beckman Coulter, Immunom Operat, Marseille, France
[12] Radboud Univ Nijmegen Med Ctr, Cent Hematol Lab, Nijmegen, Netherlands
[13] Univ Regensburg, Inst Clin Chem & Lab Med, Regensburg, Germany
[14] Erasmus MC, Dept Internal Oncol, Lab Clin & Tumor Immunol, Rotterdam, Netherlands
关键词
tetramer; flow cytometry; CD8 T cells; multicenter evaluation; standardization;
D O I
10.1002/cyto.b.20028
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: HLA class I peptide tetramers represent powerful diagnostic tools for detection and monitoring of antigen-specific CD8(+) T cells. The impetus for the current multicenter study is the critical need to standardize tetramer flow cytometry if it is to be implemented as a routine diagnostic assay. Hence, the European Working Group on Clinical Cell Analysis set out to develop and evaluate a single-platform tetramer-based method that used cytomegalovirus (CMV) as the antigenic model. Methods: Absolute numbers of CMV-specific CD8(+) T cells were obtained by combining the percentage of tetramer-binding cells with the absolute CD8(+) T-cell count. Six send-outs of stabilized blood from healthy individuals or CMV-carrying donors with CMV-specific CD8(+) T-cell counts of 3 to 10 cells/mul were distributed to 7 to 16 clinical sites. These sites were requested to enumerate CD8(+) T cells and, in the case of CMV-positive donors, CMV-specific subsets on three separate occasions using the standard method.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [1] Enumeration of antigen-specific CD8+T cells by single-platform, HLA tetramer-based flow cytometry: A European multicenter study
    Heijnen, IAFM
    Gratama, JW
    CYTOMETRY PART A, 2004, 59A (01): : 65 - 65
  • [2] Flow cytometric enumeration of Class IHLA-restricted, peptide-specific CD8+ T lymphocytes using tetramer technology and single-platform absolute T-cell counting
    Kraan, J
    Arroz, M
    Keeney, M
    Freire, M
    Weir, K
    Heijnen, I
    Gratama, JW
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2003, 17 (03): : 268 - 278
  • [3] Analytical Performance of a Standardized Single-Platform MHC Tetramer Assay for the Identification and Enumeration of CMV-Specific CD8+T Lymphocytes
    Brooimans, Rik A.
    Boyce, Christopher S.
    Popma, Janice
    Broyles, Dennis A.
    Gratama, Jan W.
    Southwick, Paula C.
    Keeney, Michael
    CYTOMETRY PART A, 2008, 73A (11) : 992 - 1000
  • [4] SCREENING AND ENUMERATION OF VIRUS- AND TUMOR-ASSOCIATED ANTIGEN-SPECIFIC CD8+T LYMPHOCYTES USING STREPTAMER TECHNOLOGY AND SINGLE-PLATFORM FLOWCYTOMETRY ASSAY
    Matko, S.
    Teichert, M.
    Odendahl, M.
    Wohsmann, M.
    Tonn, T.
    CYTOTHERAPY, 2014, 16 (04) : S26 - S27
  • [5] The CIMT monitoring panel:: enumeration of antigen-specific CD8+ T lymphocytes by structural and functional assays
    Britten, C. M.
    Gouttefangeas, C.
    Schoenmaekers-Welters, M. J. P.
    Pawelec, G.
    Koch, S.
    Ottensmeier, C.
    Mander, A.
    Walter, S.
    Paschen, A.
    Mueller-Berghaus, J.
    Mackensen, A.
    Haas, I.
    Svane, I. M.
    Hadrup, S. R.
    Straten, P. T.
    Schmitt, M.
    Giannopoulos, K.
    Maier, R.
    Veelken, H.
    Bertinetti, C.
    Konur, A.
    Stevanovic, S.
    Woelfel, T.
    van der Burg, S. H.
    CANCER IMMUNOLOGY IMMUNOTHERAPY, 2007, 56 (03) : 406 - 407
  • [6] Diagnostic potential of tetramer-based monitoring of cytomegalovirus-specific CD8+ T lymphocytes in allogeneic stem cell transplantation
    Gratama, JW
    Cornelissen, JJ
    CLINICAL IMMUNOLOGY, 2003, 106 (01) : 29 - 35
  • [7] Enumeration of WT1-specific CD8+ T cells using an MHC streptamer based no-wash single-platform flow-cytometric assay
    Matko, S.
    Teichert, M.
    Tunger, A.
    Schmitz, M.
    Bornhaeuser, M.
    Tonn, T.
    TRANSFUSION MEDICINE AND HEMOTHERAPY, 2017, 44 : 74 - 75
  • [8] Antigen-specific targeting of CD8+ T cells with receptor-modified T lymphocytes
    Nguyen, P
    Geiger, TL
    GENE THERAPY, 2003, 10 (07) : 594 - 604
  • [9] Antigen-specific targeting of CD8+ T cells with receptor-modified T lymphocytes
    P Nguyen
    T L Geiger
    Gene Therapy, 2003, 10 : 594 - 604