Flow cytometric enumeration of Class IHLA-restricted, peptide-specific CD8+ T lymphocytes using tetramer technology and single-platform absolute T-cell counting

被引:0
|
作者
Kraan, J
Arroz, M
Keeney, M
Freire, M
Weir, K
Heijnen, I
Gratama, JW
机构
[1] Erasmus MC Daniel Den Hoed, Lab Clin & Tumor Immunol, Dept Internal Oncol, Dr Daniel Den Hoed Canc Ctr, NL-3075 EA Rotterdam, Netherlands
[2] Hosp Egas Moniz SA, Clin Pathol Serv, Lisbon, Portugal
[3] London Hlth Sci Ctr, Dept Hematol, London, ON, Canada
[4] Kantonsspital Aarau, Dept Lab Med, Aarau, Switzerland
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:268 / 278
页数:11
相关论文
共 40 条
  • [1] Enumeration of antigen-specific CD8+ T lymphocytes by single-platform, HLA tetramer-based flow cytometry:: A European multicenter evaluation
    Heijnen, IAFM
    Barnett, D
    Arroz, MJ
    Barry, SM
    Bonneville, M
    Brando, B
    D'hautcourt, JL
    Kern, F
    Tötterman, TH
    Marijt, EWA
    Bossy, D
    Preijers, FWMB
    Rothe, G
    Gratama, JW
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2004, 62B (01) : 1 - 13
  • [2] Analytical Performance of a Standardized Single-Platform MHC Tetramer Assay for the Identification and Enumeration of CMV-Specific CD8+T Lymphocytes
    Brooimans, Rik A.
    Boyce, Christopher S.
    Popma, Janice
    Broyles, Dennis A.
    Gratama, Jan W.
    Southwick, Paula C.
    Keeney, Michael
    CYTOMETRY PART A, 2008, 73A (11) : 992 - 1000
  • [3] Enumeration of WT1-specific CD8+ T cells using an MHC streptamer based no-wash single-platform flow-cytometric assay
    Matko, S.
    Teichert, M.
    Tunger, A.
    Schmitz, M.
    Bornhaeuser, M.
    Tonn, T.
    TRANSFUSION MEDICINE AND HEMOTHERAPY, 2017, 44 : 74 - 75
  • [4] Enumeration of WT1-specific CD8+ T cells for clinical application using an MHC Streptamer based no-wash single-platform flow-cytometric assay
    Matko, Sarah
    Teichert, Madeleine
    Tunger, Antje
    Schmitz, Marc
    Bornhauser, Martin
    Tonn, Torsten
    Odendahl, Marcus
    CYTOMETRY PART A, 2017, 91A (10) : 1001 - 1008
  • [5] Enumeration of antigen-specific CD8+T cells by single-platform, HLA tetramer-based flow cytometry: A European multicenter study
    Heijnen, IAFM
    Gratama, JW
    CYTOMETRY PART A, 2004, 59A (01): : 65 - 65
  • [6] SCREENING AND ENUMERATION OF VIRUS- AND TUMOR-ASSOCIATED ANTIGEN-SPECIFIC CD8+T LYMPHOCYTES USING STREPTAMER TECHNOLOGY AND SINGLE-PLATFORM FLOWCYTOMETRY ASSAY
    Matko, S.
    Teichert, M.
    Odendahl, M.
    Wohsmann, M.
    Tonn, T.
    CYTOTHERAPY, 2014, 16 (04) : S26 - S27
  • [7] A new volumetric hybrid flow cytometric platform: A cost effective method for absolute CD4 T-cell enumeration
    Ding, T
    Bergeron, M
    Pelletier, E
    Janossy, G
    Varro, R
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2005, 68B (01) : 57 - 57
  • [8] Generation of primary peptide-specific CD8+ cytotoxic T-lymphocytes in vitro using allogeneic dendritic cells
    Peshwa, MV
    Benike, C
    Dupuis, M
    Kundu, SK
    Engleman, EG
    Merigan, TC
    van Schooten, WCA
    CELL TRANSPLANTATION, 1998, 7 (01) : 1 - 9
  • [9] Activated human γδ T cells induce peptide-specific CD8+ T-cell responses to tumor-associated self-antigens
    Altvater, Bianca
    Pscherer, Sibylle
    Landmeier, Silke
    Kailayangiri, Sareetha
    Savoldo, Barbara
    Juergens, Heribert
    Rossig, Claudia
    CANCER IMMUNOLOGY IMMUNOTHERAPY, 2012, 61 (03) : 385 - 396
  • [10] MHC class I-restricted killing of human oligodendrocytes by myelin basic protein peptide-specific CD8 T lymphocytes
    Jurewicz, A
    Biddison, WE
    Antel, JP
    NEUROLOGY, 1997, 48 (03) : 64003 - 64003