Enumeration of antigen-specific CD8+ T lymphocytes by single-platform, HLA tetramer-based flow cytometry:: A European multicenter evaluation

被引:20
|
作者
Heijnen, IAFM [1 ]
Barnett, D
Arroz, MJ
Barry, SM
Bonneville, M
Brando, B
D'hautcourt, JL
Kern, F
Tötterman, TH
Marijt, EWA
Bossy, D
Preijers, FWMB
Rothe, G
Gratama, JW
机构
[1] Kantonsspital Aarau, Dept Lab Med, Div Immunol, CH-5001 Aarau, Switzerland
[2] Royal Hallamshire Hosp, Dept Hematol, Sheffield, S Yorkshire, England
[3] Hosp Egas Moniz SA, Flow Cytometry Unit, Lisbon, Portugal
[4] Royal Free Hosp, Dept Clin Immunol, London, England
[5] Inst Biol, INSERM Unite 463, Nantes, France
[6] Osped Niguarda Ca Granda, Transplant Immunol & Hematol Lab, Milan, Italy
[7] Hop Warquignies, Lab Cytometr, Boussu, Belgium
[8] Univ Hosp Charite, Inst Med Immunol, Berlin, Germany
[9] Univ Uppsala Hosp, Dept Clin Immunol, Uppsala, Sweden
[10] Leiden Univ, Med Ctr, Dept Hematol, Leiden, Netherlands
[11] Beckman Coulter, Immunom Operat, Marseille, France
[12] Radboud Univ Nijmegen Med Ctr, Cent Hematol Lab, Nijmegen, Netherlands
[13] Univ Regensburg, Inst Clin Chem & Lab Med, Regensburg, Germany
[14] Erasmus MC, Dept Internal Oncol, Lab Clin & Tumor Immunol, Rotterdam, Netherlands
关键词
tetramer; flow cytometry; CD8 T cells; multicenter evaluation; standardization;
D O I
10.1002/cyto.b.20028
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: HLA class I peptide tetramers represent powerful diagnostic tools for detection and monitoring of antigen-specific CD8(+) T cells. The impetus for the current multicenter study is the critical need to standardize tetramer flow cytometry if it is to be implemented as a routine diagnostic assay. Hence, the European Working Group on Clinical Cell Analysis set out to develop and evaluate a single-platform tetramer-based method that used cytomegalovirus (CMV) as the antigenic model. Methods: Absolute numbers of CMV-specific CD8(+) T cells were obtained by combining the percentage of tetramer-binding cells with the absolute CD8(+) T-cell count. Six send-outs of stabilized blood from healthy individuals or CMV-carrying donors with CMV-specific CD8(+) T-cell counts of 3 to 10 cells/mul were distributed to 7 to 16 clinical sites. These sites were requested to enumerate CD8(+) T cells and, in the case of CMV-positive donors, CMV-specific subsets on three separate occasions using the standard method.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [31] Role of CD28 for the generation and expansion of antigen-specific CD8+ T lymphocytes during infection with Listeria monocytogenes
    Mittrücker, HW
    Kursar, N
    Köhler, A
    Hurwitz, R
    Kaufmann, SHE
    JOURNAL OF IMMUNOLOGY, 2001, 167 (10): : 5620 - 5627
  • [32] In vitro platform establishes antigen-specific CD8+ T cell cytotoxicity to encapsulated cells via indirect antigen recognition
    Li, Ying
    Frei, Anthony W.
    Yang, Ethan Y.
    Labrada-Miravet, Irayme
    Sun, Chuqiao
    Rong, Yanan
    Samojlik, Magdalena M.
    Bayer, Allison L.
    Stabler, Cherie L.
    BIOMATERIALS, 2020, 256
  • [33] Field evaluation in Chad of community usage of CD4 T lymphocyte counting by alternative single-platform flow cytometry
    Koyalta, Donato
    Jenabian, Mohammad-Ali
    Djouater, Barou
    Djemadji-Oudjeil, Noel
    Mbopi-Keou, Francois-Xavier
    Ndjoyi-Mbiguino, Angelique
    Belec, Laurent
    BMC HEALTH SERVICES RESEARCH, 2013, 13
  • [34] MHC multimer assays: optimized conditions allowing enumeration of low-affinity, antigen specific CD4+ and CD8+ T cells by flow cytometry
    Jakobsen, T.
    IMMUNOLOGY, 2011, 135 : 77 - 77
  • [35] Detection and enrichment of antigen-specific CD4+ and CD8+ T cells based on cytokine secretion
    Campbell, JDM
    METHODS, 2003, 31 (02) : 150 - 159
  • [36] Field evaluation in Chad of community usage of CD4 T lymphocyte counting by alternative single-platform flow cytometry
    Donato Koyalta
    Mohammad-Ali Jenabian
    Barou Djouater
    Noël Djemadji-Oudjeil
    Francois-Xavier Mbopi-Keou
    Angélique Ndjoyi-Mbiguino
    Laurent Bélec
    BMC Health Services Research, 13
  • [37] Development and characterization of naive single-type tumor antigen-specific CD8+ T lymphocytes from murine pluripotent stem cells
    Lei, Fengyang
    Haque, Mohammad
    Sandhu, Praneet
    Ravi, Swetha
    Song, Jianyong
    Ni, Bing
    Zheng, Songguo
    Fang, Deyu
    Jia, Hongyan
    Yang, Jin-Ming
    Song, Jianxun
    ONCOIMMUNOLOGY, 2017, 6 (07):
  • [38] TETRAMER-BASED QUANTIFICATION OF CYTOMEGALOVIRUS (CMV)-SPECIFIC CD4+ AND CD8+ T LYMPHOCYTES AFTER ALLOGENEIC STEM CELL TRANSPLANTATION MAY IDENTIFY PATIENTS AT RISK FOR CMV INFECTION DISEASE
    Pastore, D.
    Mestice, A.
    Delia, M.
    Leo, M.
    Carluccio, P.
    Ricco, A.
    Mazzone, A.
    Mongelli, R.
    Casanova, M.
    Liso, V.
    Specchia, G.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2008, 93 : 331 - 332
  • [39] Tetramer-based quantification of cytomegalovirus (CMV)specific CD4+ and CD8+ T lymphocytes after allogeneic stem cell transplantation may identify patients at risk for CMV infection/disease
    Pastore, D.
    Mestice, A.
    Leo, M.
    Giannoccaro, M.
    Mazzone, A.
    Rossi, A. Russo
    Sgherza, N.
    Longo, C.
    Angarano, R.
    Liso, V.
    Specchia, G.
    BONE MARROW TRANSPLANTATION, 2008, 41 : S266 - S266
  • [40] Peptide/MHC Tetramer-Based Sorting of CD8+ T Cells to a Leukemia Antigen Yields Clonotypes Drawn Nonspecifically from an Underlying Restricted Repertoire
    Hunsucker, Sally A.
    McGary, Colleen S.
    Vincent, Benjamin G.
    Enyenihi, Atim A.
    Waugh, Jennifer P.
    McKinnon, Karen P.
    Bixby, Lisa M.
    Ropp, Patricia A.
    Coghill, James M.
    Wood, William A.
    Gabriel, Don A.
    Sarantopoulos, Stefanie
    Shea, Thomas C.
    Serody, Jonathan S.
    Alatrash, Gheath
    Rodriguez-Cruz, Tania
    Lizee, Gregory
    Buntzman, Adam S.
    Frelinger, Jeffrey A.
    Glish, Gary L.
    Armistead, Paul M.
    CANCER IMMUNOLOGY RESEARCH, 2015, 3 (03) : 228 - 235