Thin Layer Coulometry with Ionophore Based Ion-Selective Membranes

被引:71
|
作者
Grygolowicz-Pawlak, Ewa [1 ]
Bakker, Eric [1 ]
机构
[1] Curtin Univ Technol, Nanochem Res Inst, Dept Chem, Perth, WA 6845, Australia
基金
澳大利亚研究理事会; 美国国家卫生研究院;
关键词
LIQUID-MEMBRANE; BULK OPTODES; SENSORS; ELECTRODES; INTERFACE; POTENTIOMETRY; ELECTROLYSIS; TITRATIONS; VIEW; LEAD;
D O I
10.1021/ac100524z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We are demonstrating here for the first time a thin layer coulometric detection mode for ionophore based liquid ion-selective membranes. Coulometry promises to achieve the design of robust, calibration free sensors that are especially attractive for applications where recalibration in situ is difficult or undesirable. This readout principle is here achieved with porous polypropylene tubing doped with the membrane material and which contains a chlorinated silver wire in the inner compartment, together with the fluidically delivered sample solution. The membrane material consists of the lipophilic plasticizer dodecyl 2-nitrophenyl ether, the lipophilic electrolyte ETH 500, and the calcium ionophore ETH 5234. Importantly and in contrast to earlier work on voltammetric liquid membrane electrodes, the membrane also contains a cation-exchanger salt, KTFPB. This renders the membrane permselective and allows one to observe open circuit potentiometric responses for the device, which is confirmed to follow the expected Nernstian equation. Moreover, as the same cationic species is now potential determining at both interfaces of the membrane, it is possible to use rapidly diffusing and/or thin membrane systems where transport processes at the inner and outer interface of the membrane do not perturb each other or the overall composition of the membrane. The tubing is immersed in an electrolyte solution where the counter and working electrode are placed, and the potentials are applied relative to the measured open circuit potentials. Exhaustive current decays are observed in the range of 10 to 100 mu M calcium chloride. The observed charge, calculated as integrated currents, is linearly dependent on concentration and forms the basis for the coulometric readout of ion-selective membrane electrodes.
引用
收藏
页码:4537 / 4542
页数:6
相关论文
共 50 条
  • [41] Ion-ionophore interactions in polymeric membranes studied by thin layer voltammetry
    Mao, Canwei
    Robinson, Kye J.
    Yuanb, Dajing
    Bakker, Eric
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 358
  • [42] FLICKER NOISE OF ION-SELECTIVE MEMBRANES AND TURBULENT CONVECTION IN DEPLETED LAYER
    LIFSON, S
    GAVISH, B
    REICH, S
    BIOPHYSICS OF STRUCTURE AND MECHANISM, 1978, 4 (01): : 53 - 65
  • [43] Thin layer coulometry ion sensing protocol with potassium-selective membrane electrodes
    Grygolowicz-Pawlak, Ewa
    Bakker, Eric
    ELECTROCHIMICA ACTA, 2011, 56 (28) : 10359 - 10363
  • [44] Multianalyte detection using potentiometric ionophore-based ion-selective electrodes
    Cuartero, M.
    Ruiz, A.
    Oliva, D. J.
    Ortuno, J. A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 243 : 144 - 151
  • [45] Voltammetric determination of phosphates using ion-selective electrode based on organotin ionophore
    Martynov, Leonid Yu.
    Sergeeva, Anastasia S.
    Sakharov, Konstantin A.
    Shkinev, Valery M.
    Yashtulov, Nikolai A.
    Zaitsev, Nikolai K.
    MICROCHEMICAL JOURNAL, 2023, 191
  • [46] Magnesium ion-selective optodes based on a neutral ionophore and a lipophilic cationic dye
    Siswanta, D
    Hisamoto, H
    Sato, S
    Matsumoto, Y
    Koike, Y
    Yamamori, S
    Suzuki, K
    ANALYTICAL SCIENCES, 1997, 13 (03) : 429 - 435
  • [47] Ion-selective Membranes Prepared Upon Layer-by-Layer Assembly of Azamacrocycles and Polyelectrolytes
    Hoffmann, Kristina
    El-Hashani, Ashraf
    Tieke, Bernd
    MACROMOLECULAR SYMPOSIA, 2010, 287 : 22 - 31
  • [48] Magnesium Ion-Selective Optodes Based on a Neutral Ionophore and a Lipophilic Cationic Dye
    Dwi Siswanta
    Hideaki Hisamoto
    Sayaka Sato
    Yukihiro Matsumoto
    Yasuhiro Koike
    Shinji Yamamori
    Koji Suzuki
    Analytical Sciences, 1997, 13 : 429 - 435
  • [49] Voltammetric Ion-Selective Electrodes in Thin-Layer Samples: Absolute Detection of Ions Using Ultrathin Membranes
    Liu, Yujie
    Crespo, Gaston A.
    Cuartero, Maria
    ANALYTICAL CHEMISTRY, 2024, 96 (03) : 1147 - 1155
  • [50] Bilayer membranes for ion-selective electrodes
    Kisiel, Anna
    Michalska, Agata
    Maksymiuk, Krzysztof
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 766 : 128 - 134