Thin Layer Coulometry with Ionophore Based Ion-Selective Membranes

被引:71
|
作者
Grygolowicz-Pawlak, Ewa [1 ]
Bakker, Eric [1 ]
机构
[1] Curtin Univ Technol, Nanochem Res Inst, Dept Chem, Perth, WA 6845, Australia
基金
澳大利亚研究理事会; 美国国家卫生研究院;
关键词
LIQUID-MEMBRANE; BULK OPTODES; SENSORS; ELECTRODES; INTERFACE; POTENTIOMETRY; ELECTROLYSIS; TITRATIONS; VIEW; LEAD;
D O I
10.1021/ac100524z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We are demonstrating here for the first time a thin layer coulometric detection mode for ionophore based liquid ion-selective membranes. Coulometry promises to achieve the design of robust, calibration free sensors that are especially attractive for applications where recalibration in situ is difficult or undesirable. This readout principle is here achieved with porous polypropylene tubing doped with the membrane material and which contains a chlorinated silver wire in the inner compartment, together with the fluidically delivered sample solution. The membrane material consists of the lipophilic plasticizer dodecyl 2-nitrophenyl ether, the lipophilic electrolyte ETH 500, and the calcium ionophore ETH 5234. Importantly and in contrast to earlier work on voltammetric liquid membrane electrodes, the membrane also contains a cation-exchanger salt, KTFPB. This renders the membrane permselective and allows one to observe open circuit potentiometric responses for the device, which is confirmed to follow the expected Nernstian equation. Moreover, as the same cationic species is now potential determining at both interfaces of the membrane, it is possible to use rapidly diffusing and/or thin membrane systems where transport processes at the inner and outer interface of the membrane do not perturb each other or the overall composition of the membrane. The tubing is immersed in an electrolyte solution where the counter and working electrode are placed, and the potentials are applied relative to the measured open circuit potentials. Exhaustive current decays are observed in the range of 10 to 100 mu M calcium chloride. The observed charge, calculated as integrated currents, is linearly dependent on concentration and forms the basis for the coulometric readout of ion-selective membrane electrodes.
引用
收藏
页码:4537 / 4542
页数:6
相关论文
共 50 条
  • [21] Ionophore-based ion-selective potentiometric and optical sensors
    R. Daniel Johnson
    Leonidas G. Bachas
    Analytical and Bioanalytical Chemistry, 2003, 376 : 328 - 341
  • [22] Ionophore-based ion-selective potentiometric and optical sensors
    Johnson, RD
    Bachas, LG
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (03) : 328 - 341
  • [23] Polyurethane Ionophore-Based Thin Layer Membranes for Voltammetric Ion Activity Sensing
    Cuartero, Maria
    Crespo, Gaston A.
    Bakker, Eric
    ANALYTICAL CHEMISTRY, 2016, 88 (11) : 5649 - 5654
  • [24] Fluorous Polymeric Membranes for Ionophore-Based Ion-Selective Potentiometry: How Inert Is Teflon AF?
    Lai, Chun-Ze
    Koseoglu, Secil S.
    Lugert, Elizabeth C.
    Boswell, Paul G.
    Rabai, Jozsef
    Lodge, Timothy P.
    Buhlmann, Philippe
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (04) : 1598 - 1606
  • [25] THIN-FILM ION-SELECTIVE SENSORS BASED ON NEUTRAL CARRIER MEMBRANES
    KEPLINGER, F
    GLATZ, R
    JACHIMOWICZ, A
    URBAN, G
    KOHL, F
    OLCAYTUG, F
    PROHASKA, OJ
    SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) : 272 - 274
  • [26] Ion-selective membranes based on chalcogenide glasses
    Tomova, R
    Stoycheva-Topalova, R
    Buroff, A
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2005, 7 (03): : 1399 - 1406
  • [27] Visible and FTIR microscopic observation of bisthiourea ionophore aggregates in ion-selective electrode membranes
    Phillips, KN
    Lantz, C
    Bühlmann, P
    ELECTROANALYSIS, 2005, 17 (22) : 2019 - 2025
  • [28] Thin Layer Coulometry Based on Ion-Exchanger Membranes for Heparin Detection in Undiluted Human Blood
    Crespo, Gaston A.
    Afshar, Majid Ghahraman
    Dorokhin, Denis
    Bakker, Eric
    ANALYTICAL CHEMISTRY, 2014, 86 (03) : 1357 - 1360
  • [29] Calix[4]resorcinarene ionophore in the ion-selective electrodes with plasticized poly(vinylchloride) membranes
    Muslinkina, LA
    Evtugyn, GA
    Kazakova, EK
    Budnikov, HC
    JOURNAL OF INCLUSION PHENOMENA AND MACROCYCLIC CHEMISTRY, 1999, 35 (1-2) : 361 - 367
  • [30] Calix[4]resorcinarene Ionophore in the Ion-Selective Electrodes with Plasticized Poly(vinylchloride) Membranes
    Liya A. Muslinkina
    Gennady A. Evtugyn
    Ella Kh. Kazakova
    Herman C. Budnikov
    Journal of inclusion phenomena and macrocyclic chemistry, 1999, 35 : 361 - 367