Thin Layer Coulometry with Ionophore Based Ion-Selective Membranes

被引:71
|
作者
Grygolowicz-Pawlak, Ewa [1 ]
Bakker, Eric [1 ]
机构
[1] Curtin Univ Technol, Nanochem Res Inst, Dept Chem, Perth, WA 6845, Australia
基金
澳大利亚研究理事会; 美国国家卫生研究院;
关键词
LIQUID-MEMBRANE; BULK OPTODES; SENSORS; ELECTRODES; INTERFACE; POTENTIOMETRY; ELECTROLYSIS; TITRATIONS; VIEW; LEAD;
D O I
10.1021/ac100524z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We are demonstrating here for the first time a thin layer coulometric detection mode for ionophore based liquid ion-selective membranes. Coulometry promises to achieve the design of robust, calibration free sensors that are especially attractive for applications where recalibration in situ is difficult or undesirable. This readout principle is here achieved with porous polypropylene tubing doped with the membrane material and which contains a chlorinated silver wire in the inner compartment, together with the fluidically delivered sample solution. The membrane material consists of the lipophilic plasticizer dodecyl 2-nitrophenyl ether, the lipophilic electrolyte ETH 500, and the calcium ionophore ETH 5234. Importantly and in contrast to earlier work on voltammetric liquid membrane electrodes, the membrane also contains a cation-exchanger salt, KTFPB. This renders the membrane permselective and allows one to observe open circuit potentiometric responses for the device, which is confirmed to follow the expected Nernstian equation. Moreover, as the same cationic species is now potential determining at both interfaces of the membrane, it is possible to use rapidly diffusing and/or thin membrane systems where transport processes at the inner and outer interface of the membrane do not perturb each other or the overall composition of the membrane. The tubing is immersed in an electrolyte solution where the counter and working electrode are placed, and the potentials are applied relative to the measured open circuit potentials. Exhaustive current decays are observed in the range of 10 to 100 mu M calcium chloride. The observed charge, calculated as integrated currents, is linearly dependent on concentration and forms the basis for the coulometric readout of ion-selective membrane electrodes.
引用
收藏
页码:4537 / 4542
页数:6
相关论文
共 50 条
  • [31] Salicylate Ion-Selective Electrode Based on a Calix[4]arene as Ionophore
    Ayanoglu, Melek Nur
    Erturun, H. Elif Kormali
    Ozel, Ayca Demirel
    Sahin, Ozlem
    Yilmaz, Mustafa
    Kilic, Esma
    ELECTROANALYSIS, 2015, 27 (07) : 1676 - 1684
  • [32] Ion-Selective Electrodes Based on Hydrophilic Ionophore-Modified Nanopores
    Papp, Soma
    Jagerszki, Gyula
    Gyurcsanyi, Robert E.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2018, 57 (17) : 4752 - 4755
  • [33] Highly Selective Detection of Silver in the Low ppt Range with Ion-Selective Electrodes Based on Ionophore-Doped Fluorous Membranes
    Lai, Chun-Ze
    Fierke, Melissa A.
    da Costa, Rosenildo Correa
    Gladysz, John A.
    Stein, Andreas
    Buehlmann, Philippe
    ANALYTICAL CHEMISTRY, 2010, 82 (18) : 7634 - 7640
  • [34] Mathematical model of current-polarized ionophore-based ion-selective membranes:: Large current chronopotentiometry
    Zook, Justin M.
    Buck, Richard P.
    Gyurcsanyi, Robert E.
    Lindner, Erno
    ELECTROANALYSIS, 2008, 20 (03) : 259 - 269
  • [35] Synthesis and Characterization of a Novel, Colored Lipophilic Additive for Spectral Imaging the Transport in Ionophore Based Ion-Selective Membranes
    Moczar, Ildiko
    Gyurcsanyi, Robert E.
    Huszthy, Peter
    Jagerszki, Gyula
    Toth, Klara
    Lindner, Erno
    ELECTROANALYSIS, 2006, 18 (13-14) : 1396 - 1407
  • [36] TRANSPORT IN ION-SELECTIVE MEMBRANES
    PETERSON, MA
    GREGOR, HP
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1958, 105 (03) : C53 - C53
  • [37] Anomalous potentiometric response of solid-contact ion-selective electrodes with thin-layer membranes
    Han, Tingting
    Kalinichev, Andrey, V
    Mousavi, Zekra
    Mikhelson, Konstantin N.
    Bobacka, Johan
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 357
  • [38] SELECTIVE ION-TRANSPORT IN ACETONITRILE ACROSS THE IONOPHORE-IMMOBILIZED POLYMER MEMBRANES USED AS THE SENSOR OF THE ION-SELECTIVE ELECTRODES
    NAKAMURA, T
    UEDA, T
    FUJIMORI, K
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1992, 65 (01) : 19 - 22
  • [39] NEW [4.4.4.4]CYCLOPHANE AS IONOPHORE FOR ION-SELECTIVE ELECTRODES
    Varvari, Lidia
    Popescu, Ionel Catalin
    Dorneanu, Sorin Aurel
    STUDIA UNIVERSITATIS BABES-BOLYAI CHEMIA, 2008, 53 (01): : 113 - 118
  • [40] Evaluating actinomycin as an ionophore for ion-selective electrodes.
    Jackson, PL
    Johnson, RD
    Bachas, LG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U362 - U362