An in-house software program for quantitative image quality evaluation of linac cone-beam CT system

被引:0
|
作者
Sakaria, Kasmayanti [1 ]
Lim, S. Y. [1 ]
Zin, Hafiz M. [1 ]
机构
[1] Univ Sains Malaysia, Adv Med & Dent Inst, Kepala Batas 13200, Pulau Pinang, Malaysia
关键词
GUIDED RADIATION-THERAPY; ASSURANCE;
D O I
10.1088/1742-6596/1248/1/012053
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The study presents application of an in-house software program to calculate image quality parameters of kV cone-beam CT (CBCT) system in radiotherapy. The parameters include uniformity, noise, contrast-to-noise ratio, CT number linearity, spatial resolution and geometric distortion as recommended in AAPM TG142 and TG179 quality assurance (QA) programme for image quality performance of kV CBCT. The computer algorithm packaged in the software program is developed using MATLAB (MathWorks, Natick, MA). The algorithm was optimised for two CT image quality phantoms, Catphan 600 (The Phantom Laboratory, Salem, NY) and CIRS 062QA ( CIRS, Norfolk, VA). The phantoms were scanned with XVI CBCT system (Elekta AB, Stockholm, Sweden) using an optimised CT imaging protocol. The algorithm measures the image quality metrices from the corresponding image quality test patterns in the reconstructed CT images. The algorithm provides image quality parameters from both phantoms quantitatively. The software program allows the results to be exported and recorded in MS Excel for monitoring the performance trend of the image quality parameters. The software reduces measurement uncertainties from qualitative human observation of the test patterns.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Quantitative Performance Evaluation of Mobile Cone-Beam CT for Head and Neck Imaging
    Thongvigitmanee, Saowapak S.
    Narkbuakaew, Walita
    Aootaphao, Sorapong
    Thanasupsombat, Chalinee
    Wangkaoom, Kongyot
    Kiang-ia, Atthasak
    Jitsaard, Jaturong
    Chunkiri, Thossapol
    Puttawibul, Puttisak
    Thajchayapong, Pairash
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 63 - 67
  • [42] Cone-beam CT versus Multidetector CT in Postoperative Cochlear Implant Imaging: Evaluation of Image Quality and Radiation Dose
    Helal, R. A.
    Jacob, R.
    Elshinnawy, M. A.
    Othman, A., I
    Al-Dhamari, I. M.
    Paulus, D. W.
    Abdelaziz, T. T.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (02) : 362 - 367
  • [43] Evaluation of the projection ordering for cone-beam CT
    Kong, Huihua
    Pan, Jinxiao
    Journal of Computational Information Systems, 2012, 8 (10): : 4031 - 4038
  • [44] Prediction of detectability of the mandibular canal by quantitative image quality evaluation using cone beam CT
    Takeshita, Yohei
    Shimizu, Mayumi
    Jasa, Gainer R.
    Weerawanich, Warangkana
    Okamura, Kazutoshi
    Yoshida, Shoko
    Tokumori, Kenji
    Asaumi, Junichi
    Yoshiura, Kazunori
    DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (04)
  • [45] Cone-beam volumetric CT imagers: simulations for rapid prototype system design and prediction of image quality
    Walter, DJ
    Ren, B
    Pfoh, AH
    Edic, PM
    Wu, X
    LeBlanc, JW
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 822 - 827
  • [46] Biplane interventional pediatric system with cone-beam CT: dose and image quality characterization for the default protocols
    Corredoira, Eva
    Vano, Eliseo
    Alejo, Luis
    Ubeda, Carlos
    Gutierrez-Larraya, Federico
    Garayoa, Julia
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 357 - 376
  • [47] Image quality of a cone beam CT system for image guided radiotherapy
    Sonke, JJ
    Remeijer, P
    van Herk, M
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S28 - S29
  • [48] Performance Evaluation of a Dual Cone-Beam CT (Dual CBCT) System
    Li, H.
    Giles, W.
    Roper, J.
    Bowsher, J.
    Yin, F.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [49] Image quality of an investigational imaging panel for use with the imaging beam line cone-beam CT
    Beltran, Chris
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (01): : 76 - 83
  • [50] Cone-Beam CT Reconstruction with Deformed Prior Image
    Zhang, H.
    Ouyang, L.
    Huang, J.
    Ma, J.
    Chen, W.
    Wang, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 527 - 527