An in-house software program for quantitative image quality evaluation of linac cone-beam CT system

被引:0
|
作者
Sakaria, Kasmayanti [1 ]
Lim, S. Y. [1 ]
Zin, Hafiz M. [1 ]
机构
[1] Univ Sains Malaysia, Adv Med & Dent Inst, Kepala Batas 13200, Pulau Pinang, Malaysia
关键词
GUIDED RADIATION-THERAPY; ASSURANCE;
D O I
10.1088/1742-6596/1248/1/012053
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The study presents application of an in-house software program to calculate image quality parameters of kV cone-beam CT (CBCT) system in radiotherapy. The parameters include uniformity, noise, contrast-to-noise ratio, CT number linearity, spatial resolution and geometric distortion as recommended in AAPM TG142 and TG179 quality assurance (QA) programme for image quality performance of kV CBCT. The computer algorithm packaged in the software program is developed using MATLAB (MathWorks, Natick, MA). The algorithm was optimised for two CT image quality phantoms, Catphan 600 (The Phantom Laboratory, Salem, NY) and CIRS 062QA ( CIRS, Norfolk, VA). The phantoms were scanned with XVI CBCT system (Elekta AB, Stockholm, Sweden) using an optimised CT imaging protocol. The algorithm measures the image quality metrices from the corresponding image quality test patterns in the reconstructed CT images. The algorithm provides image quality parameters from both phantoms quantitatively. The software program allows the results to be exported and recorded in MS Excel for monitoring the performance trend of the image quality parameters. The software reduces measurement uncertainties from qualitative human observation of the test patterns.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Measurements for quality assurance in the cone-beam CT
    Walter, C.
    Wertz, H.
    Steil, V.
    Lohr, F.
    Wenz, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 95 - 96
  • [32] Quality assurance of megavoltage cone-beam CT
    Morin, O.
    Aubin, M.
    Aubry, J.
    Chen, J.
    Descovich, M.
    Pouliot, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2634 - 2634
  • [33] Evaluation of MegaVoltage Cone Beam CT image quality with an unmodified Elekta Precise Linac and EPID: a feasibility study
    Markwell, Tim
    Perera, Lakshal
    Trapp, Jamie
    Fielding, Andrew
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (02) : 291 - 302
  • [34] Evaluation of MegaVoltage Cone Beam CT image quality with an unmodified Elekta Precise Linac and EPID: a feasibility study
    Tim Markwell
    Lakshal Perera
    Jamie Trapp
    Andrew Fielding
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 291 - 302
  • [35] Dose and Image Quality Evaluation for Partial and Full-Angle Kilovoltage Cone-Beam CT Protocols
    Kim, S.
    Yoo, S.
    Yin, F.
    Samei, E.
    Yoshizumi, T.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [36] Improving Image Quality of Cone-Beam CT Using Alternating Regression Forest
    Lei, Yang
    Tang, Xiangyang
    Higgins, Kristin
    Wang, Tonghe
    Liu, Tian
    Dhabaan, Anees
    Shim, Hyunsuk
    Curran, Walter J.
    Yang, Xiaofeng
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [37] Image Quality Optimization and Soft Tissue Visualization in Cone-Beam CT Imaging
    Castonguay-Henri, Aude
    Matenine, Dmitri
    Schmittbuhl, Matthieu
    de Guise, Jacques A.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 283 - 288
  • [38] Multi-Institution Analysis of Cone-Beam CT Image Quality Performance
    Becker, N.
    McNiven, A.
    Buckley, L.
    Rapley, P.
    Sabondjian, E.
    Jaffray, D.
    Letourneau, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E158 - E158
  • [39] The effect of megavoltage field size on intrafraction cone-beam CT image quality
    Friend, Georgia
    O'Connor, Patrick
    Charles, Paul
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (02) : 711 - 717
  • [40] The effect of megavoltage field size on intrafraction cone-beam CT image quality
    Georgia Friend
    Patrick O’Connor
    Paul Charles
    Physical and Engineering Sciences in Medicine, 2020, 43 : 711 - 717