An in-house software program for quantitative image quality evaluation of linac cone-beam CT system

被引:0
|
作者
Sakaria, Kasmayanti [1 ]
Lim, S. Y. [1 ]
Zin, Hafiz M. [1 ]
机构
[1] Univ Sains Malaysia, Adv Med & Dent Inst, Kepala Batas 13200, Pulau Pinang, Malaysia
来源
18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP) | 2019年 / 1248卷
关键词
GUIDED RADIATION-THERAPY; ASSURANCE;
D O I
10.1088/1742-6596/1248/1/012053
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The study presents application of an in-house software program to calculate image quality parameters of kV cone-beam CT (CBCT) system in radiotherapy. The parameters include uniformity, noise, contrast-to-noise ratio, CT number linearity, spatial resolution and geometric distortion as recommended in AAPM TG142 and TG179 quality assurance (QA) programme for image quality performance of kV CBCT. The computer algorithm packaged in the software program is developed using MATLAB (MathWorks, Natick, MA). The algorithm was optimised for two CT image quality phantoms, Catphan 600 (The Phantom Laboratory, Salem, NY) and CIRS 062QA ( CIRS, Norfolk, VA). The phantoms were scanned with XVI CBCT system (Elekta AB, Stockholm, Sweden) using an optimised CT imaging protocol. The algorithm measures the image quality metrices from the corresponding image quality test patterns in the reconstructed CT images. The algorithm provides image quality parameters from both phantoms quantitatively. The software program allows the results to be exported and recorded in MS Excel for monitoring the performance trend of the image quality parameters. The software reduces measurement uncertainties from qualitative human observation of the test patterns.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Cone-Beam Micro-CT System Based on LabVIEW Software
    Ciprian N. Ionita
    Keneth R. Hoffmann
    Daniel R. Bednarek
    Ravishankar Chityala
    Stephen Rudin
    Journal of Digital Imaging, 2008, 21 : 296 - 305
  • [22] Image quality and dose for a multisource cone-beam CT extremity scanner
    Gang, Grace J.
    Zbijewski, Wojciech
    Mahesh, Mahadevappa
    Thawait, Gaurav
    Packard, Nathan
    Yorkston, John
    Demehri, Shadpour
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2018, 45 (01) : 144 - 155
  • [23] Image quality assessment for an investigational megavoltage Cone-Beam CT device
    Chen, H.
    Simpson, L.
    Morin, O.
    Pouliot, J.
    Sarkar, A.
    MEDICAL PHYSICS, 2006, 33 (06) : 2038 - 2038
  • [24] Cone-beam Micro-CT system based on LabVIEW software
    Ionita, Ciprian N.
    Hoffmann, Keneth R.
    Bednarek, Daniel R.
    Chityala, Ravishankar
    Rudin, Stephen
    JOURNAL OF DIGITAL IMAGING, 2008, 21 (03) : 296 - 305
  • [25] Image Quality Improvement in Cone-Beam CT Using Deep Learning
    Lei, Yang
    Wang, Tonghe
    Harms, Joseph
    Shafai-Erfani, Ghazal
    Dong, Xue
    Zhou, Jun
    Patel, Pretesh
    Tang, Xiangyang
    Liu, Tian
    Curran, Walter J.
    Higgins, Kristin
    Yang, Xiaofeng
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [26] A New Reconstruction Algorithm for Improved Cone-Beam CT Image Quality
    Li, T.
    Li, X.
    Yang, Y.
    Heron, D.
    Huq, M.
    MEDICAL PHYSICS, 2009, 36 (06) : 2746 - +
  • [27] Image artifact in dental cone-beam CT
    Katsumata, A
    Hirukawa, A
    Noujeim, M
    Okumura, S
    Naitoh, M
    Fujishita, M
    Ariji, E
    Langlais, RP
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2006, 101 (05): : 652 - 657
  • [28] Quantitative Cone-Beam CT Imaging in Radiotherapy: Parallel Computation and Comprehensive Evaluation on the TrueBeam System
    Liang, Xiaokun
    Jiang, Yangkang
    Xie, Yaoqin
    Niu, Tianye
    IEEE ACCESS, 2019, 7 : 66226 - 66233
  • [29] Image quality assessment of synthetic CT from on-board cone-beam CT
    Guo, Alan
    Blais, Danis
    Carrier, Jean-Francois
    Bedwani, Stephane
    MEDICAL PHYSICS, 2021, 48 (08) : 4681 - 4682
  • [30] Effect of dose reduction on image registration and image quality for cone-beam CT in radiotherapy
    Loutfi-Krauss, B.
    Koehn, J.
    Bluemer, N.
    Freundl, K.
    Koch, T.
    Kara, E.
    Scherf, C.
    Roedel, C.
    Ramm, U.
    Licher, J.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (02) : 192 - 200