Reverse total shoulder arthroplasty baseplate stability with locking vs. non-locking peripheral screws

被引:0
|
作者
Martin, Elise J. [1 ,2 ]
Duquin, Thomas R. [2 ]
Ehrensberger, Mark T. [1 ,2 ,3 ]
机构
[1] SUNY Buffalo, Dept Biomed Engn, Buffalo, NY USA
[2] SUNY Buffalo, Dept Orthopaed Surg, Buffalo, NY USA
[3] SUNY Buffalo, Dept Biomed Engn, 3435 Main St,445 Biomed Res Bldg, Buffalo, NY 14214 USA
关键词
Total shoulder arthroplasty; Reverse total shoulder arthroplasty; Glenoid baseplate; Biomechanics; 3D digital image correlation; Peripheral screw; GLENOID COMPONENT FIXATION; KNEE ARTHROPLASTY; BONE INGROWTH; POSITION; STRAIN; MOVEMENT; DESIGN; METAL;
D O I
10.1016/j.clinbiomech.2022.105665
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: There are many options for glenosphere baseplate fixation commercially available, yet there is little biomechanical evidence supporting one type of fixation over another. In this study, we compared the biomechanical fixation of a reverse total shoulder glenoid baseplate secured with locking or non-locking peripheral screws. Methods: Both a non-augmented mini baseplate with full backing support and an augmented baseplate were testing after implantation in solid rigid polyurethane foam. Each baseplate was implanted with a 30 mm central compression screw and four peripheral screws, either locking or non-locking (15 mm anterior/posterior and 30 mm superior/inferior). A 1 Hz cyclic force of 0-750 N was applied at a 60 degrees angle for 5000 cycles. Throughout the test, the displacement of the baseplate was measured using a 3D Digital Image Correlation System. Findings: The amount of migration measured in the both the non-augmented and augment cases shows no significant differences between locking and non-locking cases at the final cycle count (non-augment: 5.66 +/- 2.29 mu m vs. 3.71 +/- 1.23 mu m; p = 0.095, augment: 15.43 +/- 8.49 mu m vs. 12.46 +/- 3.24 mu m; p = 0.314). Additionally, the amount of micromotion measured for both sample types shows the same lack of significant difference (non-augment: 10.79 +/- 5.22 mu m vs. 10.16 +/- 7.61 mu m; p = 0.388, augment: 55.03 +/- 10.13 mu m vs. 54.84 +/- 10.65 mu m; p = 0.968). Interpretation: The presence of locking versus non-locking peripheral screws does not make a significant difference on the overall stability of a glenoid baseplate, in both a no defect case with a non-augmented baseplate and a bone defect case with an augmented baseplate.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Effect of using a small baseplate on the radiological and clinical outcomes of reverse total shoulder arthroplasty in Asian patients
    Kim, J. S.
    Kim, S. H.
    Kim, S. C.
    Park, J. H.
    Kim, H. G.
    Lee, S. M.
    Yoo, J. C.
    BONE & JOINT JOURNAL, 2023, 105B (11): : 1189 - 1195
  • [42] THE FUNCTIONAL OUTCOME OF LOCKING VS NON-LOCKING DUAL PLATE FIXATION IN INTRA-ARTICULAR FRACTURE DISTAL END HUMERUS: A RETROSPECTIVE COMPARATIVE STUDY
    Bairagi, Manish
    Panwar, Mahendra
    Gupta, Sameer
    Rao, Anand
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (53): : 3511 - 3515
  • [43] Re - Dynamic locking plate vs. simple cannulated screws for nondisplaced intracapsular hip fracture
    Parker, Martyn J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (06): : 1360 - 1360
  • [44] The biomechanics of the supraspinatus-deficient shoulder treated with superior capsular reconstruction vs. reverse total shoulder arthroplasty—experimental study
    Danil Rybalko
    Aimee Bobko
    Farid Amirouche
    Dmitriy Peresada
    Awais Hussain
    Michael Patetta
    Anshum Sood
    Jason Koh
    Benjamin Goldberg
    International Orthopaedics, 2020, 44 : 2371 - 2377
  • [45] Revision to Reverse Total Shoulder Arthroplasty Restores Stability for Patients With Unstable Shoulder Prostheses
    Hernandez, Nicholas M.
    Chalmers, Brian P.
    Wagner, Eric R.
    Sperling, John W.
    Cofield, Robert H.
    Sanchez-Sotelo, Joaquin
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2017, 475 (11) : 2716 - 2722
  • [46] Anatomic factors influencing the anterior stability of reverse total shoulder arthroplasty
    Pastor, Marc-Frederic
    Smith, Tomas
    Ellwein, Alexander
    Hagenah, Jakob
    Hurschler, Christof
    Ferle, Manuel
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (12) : 2619 - 2625
  • [47] Impact of Modeling Assumptions on Stability Predictions in Reverse Total Shoulder Arthroplasty
    Dharia, Mehul A.
    Bischoff, Jeffrey E.
    Schneider, David
    FRONTIERS IN PHYSIOLOGY, 2018, 9
  • [48] ASEPTIC GLENOID BASEPLATE LOOSENING AFTER REVERSE TOTAL SHOULDER ARTHROPLASTY A Systematic Review and Meta-Analysis
    Rojas, Jorge
    Choi, Kyubo
    Joseph, Jacob
    Srikumaran, Uma
    McFarland, Edward G.
    JBJS REVIEWS, 2019, 7 (05)
  • [49] Clinical outcomes of cemented vs. uncemented reverse total shoulder arthroplasty for proximal humerus fractures: a systematic review
    Kao, David S.
    Protzuk, Omar A.
    O'Connell, Robert S.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (05): : 2063 - 2068
  • [50] Clinical outcomes of cemented vs. uncemented reverse total shoulder arthroplasty for proximal humerus fractures: a systematic review
    David S. Kao
    Omar A. Protzuk
    Robert S. O’Connell
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 2063 - 2068