Reverse total shoulder arthroplasty baseplate stability with locking vs. non-locking peripheral screws

被引:0
|
作者
Martin, Elise J. [1 ,2 ]
Duquin, Thomas R. [2 ]
Ehrensberger, Mark T. [1 ,2 ,3 ]
机构
[1] SUNY Buffalo, Dept Biomed Engn, Buffalo, NY USA
[2] SUNY Buffalo, Dept Orthopaed Surg, Buffalo, NY USA
[3] SUNY Buffalo, Dept Biomed Engn, 3435 Main St,445 Biomed Res Bldg, Buffalo, NY 14214 USA
关键词
Total shoulder arthroplasty; Reverse total shoulder arthroplasty; Glenoid baseplate; Biomechanics; 3D digital image correlation; Peripheral screw; GLENOID COMPONENT FIXATION; KNEE ARTHROPLASTY; BONE INGROWTH; POSITION; STRAIN; MOVEMENT; DESIGN; METAL;
D O I
10.1016/j.clinbiomech.2022.105665
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: There are many options for glenosphere baseplate fixation commercially available, yet there is little biomechanical evidence supporting one type of fixation over another. In this study, we compared the biomechanical fixation of a reverse total shoulder glenoid baseplate secured with locking or non-locking peripheral screws. Methods: Both a non-augmented mini baseplate with full backing support and an augmented baseplate were testing after implantation in solid rigid polyurethane foam. Each baseplate was implanted with a 30 mm central compression screw and four peripheral screws, either locking or non-locking (15 mm anterior/posterior and 30 mm superior/inferior). A 1 Hz cyclic force of 0-750 N was applied at a 60 degrees angle for 5000 cycles. Throughout the test, the displacement of the baseplate was measured using a 3D Digital Image Correlation System. Findings: The amount of migration measured in the both the non-augmented and augment cases shows no significant differences between locking and non-locking cases at the final cycle count (non-augment: 5.66 +/- 2.29 mu m vs. 3.71 +/- 1.23 mu m; p = 0.095, augment: 15.43 +/- 8.49 mu m vs. 12.46 +/- 3.24 mu m; p = 0.314). Additionally, the amount of micromotion measured for both sample types shows the same lack of significant difference (non-augment: 10.79 +/- 5.22 mu m vs. 10.16 +/- 7.61 mu m; p = 0.388, augment: 55.03 +/- 10.13 mu m vs. 54.84 +/- 10.65 mu m; p = 0.968). Interpretation: The presence of locking versus non-locking peripheral screws does not make a significant difference on the overall stability of a glenoid baseplate, in both a no defect case with a non-augmented baseplate and a bone defect case with an augmented baseplate.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Fracture fixation with two locking screws versus three non-locking screws
    Grawe, B.
    Le, T.
    Williamson, S.
    Archdeacon, A.
    Zardiackas, L.
    BONE & JOINT RESEARCH, 2012, 1 (06): : 118 - 124
  • [2] The effect of the combination of locking screws and non-locking screws on the torsional properties of a locking-plate construct
    Gordon, S.
    Moens, N. M. M.
    Runciman, J.
    Monteith, G.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2010, 23 (01) : 7 - 13
  • [3] Survivorship and clinical outcomes of reverse total shoulder arthroplasty in patients with large glenoid defects using the stilting technique and a baseplate with central ingrowth cage and peripheral locking screws
    Simcox, Trevor G.
    Hao, Kevin A.
    Dada, Oluwaferanmi
    Beason, Austin M.
    Khlopas, Anton
    Farmer, Kevin W.
    King, Joseph J.
    Schoch, Bradley S.
    Wright, Thomas W.
    Struk, Aimee M.
    Wright, Jonathan O.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2025, 34 (04) : 1071 - 1080
  • [4] Baseplate Options for Reverse Total Shoulder Arthroplasty
    Wassim Mourad
    J. Michael Wiater
    Brett P. Wiater
    Alexander Martusiewicz
    Current Reviews in Musculoskeletal Medicine, 2020, 13 : 769 - 775
  • [5] Baseplate Options for Reverse Total Shoulder Arthroplasty
    Mourad, Wassim
    Wiater, J. Michael
    Wiater, Brett P.
    Martusiewicz, Alexander
    CURRENT REVIEWS IN MUSCULOSKELETAL MEDICINE, 2020, 13 (06) : 769 - 775
  • [6] Stability of Locking and Non-Locking Plates in an Osteoporotic Calcaneal Fracture Model
    Illert, Till
    Rammelt, Stefan
    Drewes, Tim
    Grass, Rene
    Zwipp, Hans
    FOOT & ANKLE INTERNATIONAL, 2011, 32 (03) : 307 - 313
  • [7] Periprosthetic supracondylar femoral fractures above total knee arthroplasty: comparison of the locking and non-locking plating methods
    Bae, Dae Kyung
    Song, Sang Jun
    Yoon, Kyoung Ho
    Kim, Tae Yong
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (11) : 2690 - 2697
  • [8] Periprosthetic supracondylar femoral fractures above total knee arthroplasty: comparison of the locking and non-locking plating methods
    Dae Kyung Bae
    Sang Jun Song
    Kyoung Ho Yoon
    Tae Yong Kim
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 2690 - 2697
  • [9] Glenoid baseplate screw fixation in reverse shoulder arthroplasty: does locking screw position and orientation matter?
    Abdic, Sejla
    Lockhart, Jason
    Alnusif, Naser
    Johnson, James A.
    Athwal, George S.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (05) : 1207 - 1213
  • [10] Surgical performance when inserting non-locking screws: a systematic review
    Fletcher, James W. A.
    Wenzel, Lisa
    Neumann, Verena
    Richards, R. Geoff
    Gueorguiev, Boyko
    Gill, Harinderjit S.
    Preatoni, Ezio
    Whitehouse, Michael R.
    EFORT OPEN REVIEWS, 2020, 5 (01) : 26 - 36