Field evaluation of a passive personal air sampler for screening of PAH exposure in workplaces

被引:31
|
作者
Bohlin, Pernilla [1 ]
Jones, Kevin C. [2 ]
Levin, Jan-Olof [3 ]
Lindahl, Roger [3 ]
Strandberg, Bo [1 ]
机构
[1] Univ Gothenburg, Dept Occupat & Environm Med, Sahlgrenska Acad, Gothenburg, Sweden
[2] Univ Lancaster, Ctr Chem Management, Lancaster LA1 4YQ, England
[3] Umea Univ, Dept Chem, SE-90187 Umea, Sweden
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2010年 / 12卷 / 07期
基金
英国自然环境研究理事会;
关键词
POLYCYCLIC AROMATIC-HYDROCARBONS; PERSISTENT ORGANIC POLLUTANTS; PERFORMANCE ASSESSMENT; DEPURATION COMPOUNDS; DIFFUSIVE SAMPLERS; OUTDOOR AIR; CANCER-RISK; INDOOR; RATES; ENVIRONMENTS;
D O I
10.1039/c0em00018c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New sampling methods are needed to simplify and enable frequent monitoring of workers' exposure to polycyclic aromatic hydrocarbons (PAHs). The sampler needs to fulfil some key operational requirements for occupational exposure assessments: (i) be useable as a personal sampler; (ii) work over 8 h exposure time; (iii) sequester PAHs both in gas and particle phase, (iv) yield reliable estimates of air concentrations. Here, a new smaller design of the traditional polyurethane foam (PUF) passive air sampler (PAS) (i.e. a 'mini-PUF') was introduced and assessed against these requirements in sites with elevated PAH concentrations. The exposure times were 2 weeks and 8 hours. The obtained sampling rates (R-values) were not significantly different between gas phase (0.4-3.3 m(3) day(-1), 0.3-2.3 L min(-1)) and particle associated PAHs (0.5-1.9 m(3) day(-1), 0.4-1.3 L min(-1)). The accuracy in estimating air concentrations was within +/- 25% from the active sampler for half of the PAHs for the mini-PUF under 8 h exposures. Significant correlations (p < 0.003) were found between personally deployed mini-PUFs and a co-deployed personal active sampling method. This together with the low costs and ease-of-use of the mini-PUF encourage application in exposure assessments.
引用
收藏
页码:1437 / 1444
页数:8
相关论文
共 50 条
  • [41] Biomonitoring of air quality in the Cologne Conurbation using pine needles as a passive sampler - Part II: polycyclic aromatic hydrocarbons (PAH)
    Lehndorff, E
    Schwark, L
    ATMOSPHERIC ENVIRONMENT, 2004, 38 (23) : 3793 - 3808
  • [42] Measuring personal exposure to fine particulate matter (PM2.5) among rural Honduran women: A field evaluation of the Ultrasonic Personal Aerosol Sampler (UPAS)
    Pillarisetti, Ajay
    Carter, Ellison
    Rajkumar, Sarah
    Young, Bonnie N.
    Benka-Coker, Megan L.
    Peel, Jennifer L.
    Johnson, Michael
    Clark, Maggie L.
    ENVIRONMENT INTERNATIONAL, 2019, 123 : 50 - 53
  • [43] Evaluation of passive air sampler calibrations: Selection of sampling rates and implications for the measurement of persistent organic pollutants in air
    Melymuk, Lisa
    Robson, Matthew
    Helm, Paul A.
    Diamond, Miriam L.
    ATMOSPHERIC ENVIRONMENT, 2011, 45 (10) : 1867 - 1875
  • [44] DEVELOPMENT AND TESTING OF A WHOLE-AIR SAMPLER FOR MEASUREMENT OF PERSONAL EXPOSURE TO VOLATILE ORGANIC-COMPOUNDS
    WHITAKER, DA
    FORTMANN, RC
    LINDSTROM, AB
    JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 1995, 5 (01): : 89 - 100
  • [45] Field evaluation and calibration of a small axial passive air sampler for gaseous and particle bound polycyclic aromatic hydrocarbons (PAHs) and oxygenated PAHs
    Magnusson, Roger
    Arnoldsson, Kristina
    Lejon, Christian
    Hagglund, Lars
    Wingfors, Hakan
    ENVIRONMENTAL POLLUTION, 2016, 216 : 235 - 244
  • [46] Evaluation of a new passive sampler using hydrophobic zeolites as adsorbents for exposure measurement of indoor BTX
    Du, Zhengjian
    Mo, Jinhan
    Zhang, Yinping
    Li, Xinxiao
    Xu, Qiujian
    ANALYTICAL METHODS, 2013, 5 (14) : 3463 - 3472
  • [47] Evaluation of the polyurethane foam (PUF) disk passive air sampler: Computational modeling and experimental measurements
    May, Andrew A.
    Ashman, Paul
    Huang, Jiaoyan
    Dhaniyala, Suresh
    Holsen, Thomas M.
    ATMOSPHERIC ENVIRONMENT, 2011, 45 (26) : 4354 - 4359
  • [48] Passive air sampler as a tool for long-term air pollution monitoring:: Part 2.: Air genotoxic potency screening assessment
    Cupr, Pavel
    Klanova, Jana
    Bartos, Tomas
    Flegrova, Zuzana
    Kohoutek, Jiri
    Holoubek, Ivan
    ENVIRONMENTAL POLLUTION, 2006, 144 (02) : 406 - 413
  • [49] Development and field evaluation of a new diffusive sampler for hydrogen sulphide in the ambient air
    De Santis, F
    Allegrini, I
    Bellagotti, R
    Vichi, F
    Zona, D
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (04) : 897 - 901
  • [50] Development and field evaluation of a new diffusive sampler for Hydrogen Sulphide in the ambient air
    F. De Santis
    I. Allegrini
    R. Bellagotti
    F. Vichi
    D. Zona
    Analytical and Bioanalytical Chemistry, 2006, 384 : 897 - 901