Field evaluation of a passive personal air sampler for screening of PAH exposure in workplaces

被引:31
|
作者
Bohlin, Pernilla [1 ]
Jones, Kevin C. [2 ]
Levin, Jan-Olof [3 ]
Lindahl, Roger [3 ]
Strandberg, Bo [1 ]
机构
[1] Univ Gothenburg, Dept Occupat & Environm Med, Sahlgrenska Acad, Gothenburg, Sweden
[2] Univ Lancaster, Ctr Chem Management, Lancaster LA1 4YQ, England
[3] Umea Univ, Dept Chem, SE-90187 Umea, Sweden
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2010年 / 12卷 / 07期
基金
英国自然环境研究理事会;
关键词
POLYCYCLIC AROMATIC-HYDROCARBONS; PERSISTENT ORGANIC POLLUTANTS; PERFORMANCE ASSESSMENT; DEPURATION COMPOUNDS; DIFFUSIVE SAMPLERS; OUTDOOR AIR; CANCER-RISK; INDOOR; RATES; ENVIRONMENTS;
D O I
10.1039/c0em00018c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New sampling methods are needed to simplify and enable frequent monitoring of workers' exposure to polycyclic aromatic hydrocarbons (PAHs). The sampler needs to fulfil some key operational requirements for occupational exposure assessments: (i) be useable as a personal sampler; (ii) work over 8 h exposure time; (iii) sequester PAHs both in gas and particle phase, (iv) yield reliable estimates of air concentrations. Here, a new smaller design of the traditional polyurethane foam (PUF) passive air sampler (PAS) (i.e. a 'mini-PUF') was introduced and assessed against these requirements in sites with elevated PAH concentrations. The exposure times were 2 weeks and 8 hours. The obtained sampling rates (R-values) were not significantly different between gas phase (0.4-3.3 m(3) day(-1), 0.3-2.3 L min(-1)) and particle associated PAHs (0.5-1.9 m(3) day(-1), 0.4-1.3 L min(-1)). The accuracy in estimating air concentrations was within +/- 25% from the active sampler for half of the PAHs for the mini-PUF under 8 h exposures. Significant correlations (p < 0.003) were found between personally deployed mini-PUFs and a co-deployed personal active sampling method. This together with the low costs and ease-of-use of the mini-PUF encourage application in exposure assessments.
引用
收藏
页码:1437 / 1444
页数:8
相关论文
共 50 条
  • [21] Development of new reactive and sensitive passive sampler for carbonyl compounds in indoor air: Evaluation and field measurements
    Sekine, Y
    Ohnishi, M
    Sugihara, K
    Kitasaka, K
    Shimajiri, H
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 2650 - 2654
  • [22] FIELD VALIDATION OF A DIFFUSIVE SAMPLER FOR THE ASSESSMENT OF PERSONAL EXPOSURE TO SAWING FUMES
    ERIKSSON, K
    LEVIN, JO
    CHEMOSPHERE, 1995, 30 (08) : 1541 - 1549
  • [23] Development of PM0.1 Personal Sampler for Evaluation of Personal Exposure to Aerosol Nanoparticles
    Thongyen, Thunyapat
    Hata, Mitsuhiko
    Toriba, Akira
    Ikeda, Takuji
    Koyama, Hiromi
    Otani, Yoshio
    Furuuchi, Masami
    AEROSOL AND AIR QUALITY RESEARCH, 2015, 15 (01) : 180 - 187
  • [24] Development of a sensitive diffusion sampler for the measurement and assessment of personal exposure to PAHS in air
    Fan, ZH
    Lioy, P
    EPIDEMIOLOGY, 2002, 13 (04) : S219 - S219
  • [25] Evaluation and application of a passive air sampler for polycylic aromatic hydrocarbons (PAHs)
    Esen, Fatma
    Evci, Yildiz M.
    Tasdemir, Yucel
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2017, 52 (10): : 1022 - 1029
  • [26] Development of a Sampler for Evaluation of Personal Exposure to PM0.1 particles
    Thongen, Thunyapat
    Kusunoki, Masaru
    Hata, Mitsuhiko
    Bao, Linfa
    Furuuchi, Masami
    Otani, Yoshio
    Ikeda, Takuji
    29TH SYMPOSIUM ON AEROSOL SCIENCE AND TECHNOLOGY, 2012, 2012, : 233 - 234
  • [27] Evaluation and Application of a Passive Air Sampler for Atmospheric Volatile Organic Compounds
    Huang, Cenyan
    Tong, Lei
    Dai, Xiaorong
    Xiao, Hang
    AEROSOL AND AIR QUALITY RESEARCH, 2018, 18 (12) : 3047 - 3055
  • [28] Field evaluation of a tailor-made new passive sampler for the determination of NO2 levels in ambient air
    Ozden, Ozlem
    Dogeroglu, Tuncay
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2008, 142 (1-3) : 243 - 253
  • [29] Field evaluation of a tailor-made new passive sampler for the determination of NO2 levels in ambient air
    Ozlem Ozden
    Tuncay Dogeroglu
    Environmental Monitoring and Assessment, 2008, 142 : 243 - 253
  • [30] Development, characterization, and testing of a personal passive sampler for measuring inhalation exposure to gaseous elemental mercury
    Snow, Melanie A.
    Feigis, Michelle
    Lei, Ying Duan
    Mitchell, Carl P. J.
    Wania, Frank
    ENVIRONMENT INTERNATIONAL, 2021, 146