Field evaluation of a passive personal air sampler for screening of PAH exposure in workplaces

被引:31
|
作者
Bohlin, Pernilla [1 ]
Jones, Kevin C. [2 ]
Levin, Jan-Olof [3 ]
Lindahl, Roger [3 ]
Strandberg, Bo [1 ]
机构
[1] Univ Gothenburg, Dept Occupat & Environm Med, Sahlgrenska Acad, Gothenburg, Sweden
[2] Univ Lancaster, Ctr Chem Management, Lancaster LA1 4YQ, England
[3] Umea Univ, Dept Chem, SE-90187 Umea, Sweden
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2010年 / 12卷 / 07期
基金
英国自然环境研究理事会;
关键词
POLYCYCLIC AROMATIC-HYDROCARBONS; PERSISTENT ORGANIC POLLUTANTS; PERFORMANCE ASSESSMENT; DEPURATION COMPOUNDS; DIFFUSIVE SAMPLERS; OUTDOOR AIR; CANCER-RISK; INDOOR; RATES; ENVIRONMENTS;
D O I
10.1039/c0em00018c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New sampling methods are needed to simplify and enable frequent monitoring of workers' exposure to polycyclic aromatic hydrocarbons (PAHs). The sampler needs to fulfil some key operational requirements for occupational exposure assessments: (i) be useable as a personal sampler; (ii) work over 8 h exposure time; (iii) sequester PAHs both in gas and particle phase, (iv) yield reliable estimates of air concentrations. Here, a new smaller design of the traditional polyurethane foam (PUF) passive air sampler (PAS) (i.e. a 'mini-PUF') was introduced and assessed against these requirements in sites with elevated PAH concentrations. The exposure times were 2 weeks and 8 hours. The obtained sampling rates (R-values) were not significantly different between gas phase (0.4-3.3 m(3) day(-1), 0.3-2.3 L min(-1)) and particle associated PAHs (0.5-1.9 m(3) day(-1), 0.4-1.3 L min(-1)). The accuracy in estimating air concentrations was within +/- 25% from the active sampler for half of the PAHs for the mini-PUF under 8 h exposures. Significant correlations (p < 0.003) were found between personally deployed mini-PUFs and a co-deployed personal active sampling method. This together with the low costs and ease-of-use of the mini-PUF encourage application in exposure assessments.
引用
收藏
页码:1437 / 1444
页数:8
相关论文
共 50 条
  • [31] Strategy, development and laboratory calibration of a personal passive sampler for monitoring the asbestos exposure of maintenance workers
    Burdett, GJ
    Revell, G
    ADVANCES IN ENVIRONMENTAL MEASUREMENT METHODS FOR ASBESTOS, 1999, 1342 : 129 - 146
  • [32] A DIFFUSIVE SAMPLER FOR PERSONAL MONITORING OF TOLUENE DIISOCYANATE (TDI) EXPOSURE .2. LABORATORY AND FIELD-EVALUATION OF THE DOSIMETER
    RANDO, RJ
    HAMMAD, YY
    CHANG, SN
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1989, 50 (01): : 8 - 14
  • [33] Silicone Wristbands as a Personal Passive Sampler to Evaluate Indoor Exposure to Volatile and Non-volatile PFASs
    Hoxie, Taylor
    Zhang, Sharon
    Herkert, Nicholas J.
    Bauer, Rachel A.
    Guo, Ying
    Bhattacharya, Ankita
    Carignan, Courtney C.
    Hoffman, Kate
    Higgins, Christopher P.
    Stapleton, Heather M.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2024, 58 (37) : 16316 - 16326
  • [34] Polydimethylsiloxane (silicone rubber) brooch as a personal passive air sampler for semi-volatile organic compounds
    Okeme, Joseph O.
    Nguyen, Linh, V
    Lorenzo, Maria
    Dhal, Suman
    Pico, Yolanda
    Arrandale, Victoria H.
    Diamond, Miriam L.
    CHEMOSPHERE, 2018, 208 : 1002 - 1007
  • [35] Field evaluation of a passive sampler for assessing 2-ethoxyethyl acetate exposures
    Shih, TS
    Chang, HY
    Liu, HH
    Hung, YS
    Liou, SH
    JOURNAL OF OCCUPATIONAL HEALTH, 2004, 46 (06) : 479 - 485
  • [36] Calibration and field evaluation of the Chemcatcher® passive sampler for monitoring metaldehyde in surface water
    Castle, Glenn D.
    Mills, Graham A.
    Bakir, Adil
    Gravell, Anthony
    Schumacher, Melanie
    Townsend, Ian
    Jones, Lewis
    Greenwood, Richard
    Knott, Stuart
    Fones, Gary R.
    TALANTA, 2018, 179 : 57 - 63
  • [37] Initial field evaluation of the Harvard active ozone sampler for personal ozone monitoring
    Geyh, AS
    Roberts, PT
    Lurmann, FW
    Schoell, BM
    Avol, EL
    JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 1999, 9 (02): : 143 - 149
  • [38] Initial field evaluation of the Harvard active ozone sampler for personal ozone monitoring
    ALISON S GEYH
    PAUL T ROBERTS
    FREDERICK W LURMANN
    BASTIAN M SCHOELL
    EDWARD L AVOL
    Journal of Exposure Science & Environmental Epidemiology, 1999, 9 : 143 - 149
  • [39] MODIFICATION AND EVALUATION OF A THERMALLY DESORBABLE PASSIVE SAMPLER FOR VOLATILE ORGANIC-COMPOUNDS IN AIR
    COUTANT, RW
    LEWIS, RG
    MULIK, JD
    ANALYTICAL CHEMISTRY, 1986, 58 (02) : 445 - 448
  • [40] LABORATORY EVALUATION OF A NOVEL REACTIVE PASSIVE SAMPLER FOR THE QUANTITATIVE-DETERMINATION OF FORMALDEHYDE IN AIR
    DILLON, HK
    GAO, PF
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1994, 55 (11): : 1061 - 1068