Kalman-Based Calibration Algorithm for AgaMatrix Continuous Glucose Monitoring System

被引:6
|
作者
Singh, Abhinoy Kumar [1 ,2 ]
Rebec, Mihailo V. [3 ]
Haidar, Ahmad [1 ]
机构
[1] McGill Univ, Dept Biomed Engn, Montreal, PQ H3A 2B4, Canada
[2] IIT Indore, Dept Elect Engn, Indore 453552, India
[3] WaveForm Technol Inc, Wilsonville, OR 97070 USA
关键词
Glucose; Calibration; Kalman filters; Blood; Noise measurement; Current measurement; Estimation; Continuous glucose monitoring; glucose sensor; Kalman filter; parameter estimation; INTEGRAL EQUATIONS; DECONVOLUTION; ACCURACY; SENSORS; STATE;
D O I
10.1109/TCST.2020.3003450
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A continuous glucose monitoring system is composed of a glucose sensor and an estimation (calibration) algorithm. The glucose sensor is composed of an electrode that is inserted under the skin and generates a noisy electrical current in response to interstitial glucose levels. The relationship between the electrical current and the interstitial glucose levels varies between individuals and within the same individual (with sensor wear time). The estimation algorithm infers the glucose levels in the blood from the noisy electrical current signal and uses intermittent capillary glucose measurements to account for intra-and inter-individual variability. In this article, we propose a novel real-time Kalman filter-based estimation algorithm that is composed of three steps: 1) noise filtering step; 2) compartment matching step using sequential Kalman filter; and 3) parameters estimation step using the conventional Kalman filter. The initial estimate of the parameters and covariance matrix are extracted offline using a nonlinear cubature Kalman filter. Our algorithm is compared with four alternative algorithms using 20 sensor data sets. Each data set was generated over a seven-day sensor wear period, during which patients were tested on three in-clinic days (days 1, 4, and 7). The comparison is based on the mean absolute relative difference (MARD) between frequent reference glucose measurements and the sensor glucose levels. MARD for days 1, 4, and 7 were 10.3%, 10.7%, and 11.9% for our algorithm and 12.46%, 15.75%, and 14.17% for the alternative algorithm, respectively. Our algorithm is currently being integrated into a commercial continuous glucose monitoring system (AgaMatrix, Inc., Salem, NH, USA).
引用
收藏
页码:1257 / 1267
页数:11
相关论文
共 50 条
  • [41] Improving the Accuracy of Pdot-Based Continuous Glucose Monitoring by Using External Ratiometric Calibration
    Sun, Kai
    Liu, Siyang
    Liu, Jing
    Ding, Zhaoyang
    Jiang, Yifei
    Zhang, Jicheng
    Chen, Haobin
    Yu, Jiangbo
    Wu, Changfeng
    Chiu, Daniel T.
    ANALYTICAL CHEMISTRY, 2021, 93 (04) : 2359 - 2366
  • [42] Does Glucose Level at Calibration Influence Accuracy of Continuous Glucose Monitoring Readings In Vitro?
    Iscoe, Katherine E.
    Davey, Raymond J.
    Fournier, Paul A.
    DIABETES, 2011, 60 : A243 - A243
  • [43] INTERIM 365 DAY PERFORMANCE OF A LONG TERM IMPLANTABLE CONTINUOUS GLUCOSE MONITORING SYSTEM WITH REDUCED CALIBRATION
    Sanchez, P.
    Al-Khawi, L.
    Masciotti, J.
    Velvadapu, V.
    Dehennis, A.
    Tweden, K.
    Kaufman, F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A164 - A164
  • [44] Continuous glucose monitoring system for congenital hyperinsulinemia
    Md. Saif
    Akshay Kapoor
    IPS Kochar
    Radhika Jindal
    Indian Pediatrics, 2013, 50 : 421 - 422
  • [45] Continuous glucose monitoring system for diabetic cats
    Ristic, J
    Herrtage, M
    Slater, L
    Church, D
    Catchpole, B
    VETERINARY RECORD, 2003, 152 (01) : 28 - 28
  • [46] CONTINUOUS GLUCOSE MONITORING SYSTEM AND CYSTIC FIBROSIS
    Mei Hsia, Mariana Zorron
    Goncalves, Aline C.
    Morcillo, Andre Moreno
    Minicucci, Walter J.
    Ribeiro, Jose D.
    Ribeiro, Antonio F.
    HORMONE RESEARCH IN PAEDIATRICS, 2017, 88 : 173 - 173
  • [47] Continuous glucose monitoring system (CGMS) in hypoglycemia
    Harwood, K
    Aponte, L
    Rincon, M
    DiMartino-Nardi, J
    Muzumdar, R
    Saenger, P
    PEDIATRIC RESEARCH, 2004, 55 (04) : 149A - 149A
  • [48] The MiniMed Continuous Glucose Monitoring System (CGMS)
    Mastrototaro, J
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 1999, 12 : 751 - 758
  • [49] Toward a Continuous Intravascular Glucose Monitoring System
    Beier, Brooke
    Musick, Katherine
    Matsumoto, Akira
    Panitch, Alyssa
    Nauman, Eric
    Irazoqui, Pedro
    SENSORS, 2011, 11 (01) : 409 - 424
  • [50] Biosensor system for continuous glucose monitoring in fish
    Yonemori, Yuki
    Takahashi, Eiji
    Ren, Huifeng
    Hayashi, Tetsuhito
    Endo, Hideaki
    ANALYTICA CHIMICA ACTA, 2009, 633 (01) : 90 - 96