Kalman-Based Calibration Algorithm for AgaMatrix Continuous Glucose Monitoring System

被引:6
|
作者
Singh, Abhinoy Kumar [1 ,2 ]
Rebec, Mihailo V. [3 ]
Haidar, Ahmad [1 ]
机构
[1] McGill Univ, Dept Biomed Engn, Montreal, PQ H3A 2B4, Canada
[2] IIT Indore, Dept Elect Engn, Indore 453552, India
[3] WaveForm Technol Inc, Wilsonville, OR 97070 USA
关键词
Glucose; Calibration; Kalman filters; Blood; Noise measurement; Current measurement; Estimation; Continuous glucose monitoring; glucose sensor; Kalman filter; parameter estimation; INTEGRAL EQUATIONS; DECONVOLUTION; ACCURACY; SENSORS; STATE;
D O I
10.1109/TCST.2020.3003450
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A continuous glucose monitoring system is composed of a glucose sensor and an estimation (calibration) algorithm. The glucose sensor is composed of an electrode that is inserted under the skin and generates a noisy electrical current in response to interstitial glucose levels. The relationship between the electrical current and the interstitial glucose levels varies between individuals and within the same individual (with sensor wear time). The estimation algorithm infers the glucose levels in the blood from the noisy electrical current signal and uses intermittent capillary glucose measurements to account for intra-and inter-individual variability. In this article, we propose a novel real-time Kalman filter-based estimation algorithm that is composed of three steps: 1) noise filtering step; 2) compartment matching step using sequential Kalman filter; and 3) parameters estimation step using the conventional Kalman filter. The initial estimate of the parameters and covariance matrix are extracted offline using a nonlinear cubature Kalman filter. Our algorithm is compared with four alternative algorithms using 20 sensor data sets. Each data set was generated over a seven-day sensor wear period, during which patients were tested on three in-clinic days (days 1, 4, and 7). The comparison is based on the mean absolute relative difference (MARD) between frequent reference glucose measurements and the sensor glucose levels. MARD for days 1, 4, and 7 were 10.3%, 10.7%, and 11.9% for our algorithm and 12.46%, 15.75%, and 14.17% for the alternative algorithm, respectively. Our algorithm is currently being integrated into a commercial continuous glucose monitoring system (AgaMatrix, Inc., Salem, NH, USA).
引用
收藏
页码:1257 / 1267
页数:11
相关论文
共 50 条
  • [1] Calibration of the continuous glucose monitoring system for transient glucose monitoring
    Lesperance, Leann M.
    Spektor, Anna
    McLeod, Kenneth J.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2007, 9 (02) : 183 - 190
  • [2] A KALMAN-BASED FUNDAMENTAL FREQUENCY ESTIMATION ALGORITHM
    Shi, Liming
    Nielsen, Jesper K.
    Jensen, Jesper R.
    Little, Max A.
    Christensen, Mads G.
    2017 IEEE WORKSHOP ON APPLICATIONS OF SIGNAL PROCESSING TO AUDIO AND ACOUSTICS (WASPAA), 2017, : 314 - 318
  • [3] Adaptive Calibration Algorithm for Plasma Glucose Estimation in Continuous Glucose Monitoring
    Barcelo-Rico, Fatima
    Diez, Jose-Luis
    Rossetti, Paolo
    Vehi, Josep
    Bondia, Jorge
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2013, 17 (03) : 530 - 538
  • [4] PERFORMANCE ASSESSMENT OF A CONTINUOUS GLUCOSE MONITORING CALIBRATION ALGORITHM IN HYPOGLYCEMIA
    Mahmoudi, Z.
    Jensen, M. Hasselstrom
    Johansen, M. Dencker
    Christensen, T. F.
    Tarnow, L.
    Christiansen, J. S.
    Hejlesen, O. K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : A75 - A75
  • [5] Speech Enhancement Using a Kalman-based Normalized LMS Algorithm
    Mahmoodzadeh, A.
    Abutalebi, H. R.
    Agahi, H.
    2008 INTERNATIONAL SYMPOSIUM ON TELECOMMUNICATIONS, VOLS 1 AND 2, 2008, : 555 - +
  • [6] A Multistep Algorithm for Processing and Calibration of Microdialysis Continuous Glucose Monitoring Data
    Mahmoudi, Zeinab
    Johansen, Mette Dencker
    Christiansen, Jens Sandahl
    Hejlesen, Ole Kristian
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 (10) : 825 - 835
  • [7] Enhanced Algorithm for glucose estimation using the Continuous Glucose Monitoring System
    Leal, Yenny
    Garcia-Gabin, Winston
    Bondia, Jorge
    Esteve, Eduardo
    Ricart, Wifredo
    Fernandez-Real, Jose-Manuel
    Vehi, Josep
    MEDICAL SCIENCE MONITOR, 2010, 16 (06): : MT51 - MT58
  • [8] PERFORMANCE OF THE GUARDIAN™ SENSOR 3 CONTINUOUS GLUCOSE MONITORING SYSTEM WITH NO CALIBRATION
    Brazg, R.
    Bailey, T.
    Bode, B.
    Castorino, K.
    Christiansen, M.
    Kaiserman, K.
    Kudva, Y.
    Liljenquist, D.
    Shulman, D.
    Slover, R.
    Lee, S.
    Shin, J.
    Huang, S.
    Rhinehart, A.
    Vigersky, R.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 : A33 - A33
  • [9] ASSESSMENT OF POTENTIAL ERRORS IN MANUAL CALIBRATION OF A CONTINUOUS GLUCOSE MONITORING SYSTEM
    Pleus, S.
    Link, M.
    Jendrike, N.
    Haug, C.
    Freckmann, G.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 : A100 - A101
  • [10] A study of Kalman-based algorithm for the maneuvering group-target tracking
    Geng Wen-Dong
    Liu Hong-ya
    Dong Zheng-hong
    Wang Yuan-qin
    PROCEEDINGS OF 2006 CIE INTERNATIONAL CONFERENCE ON RADAR, VOLS 1 AND 2, 2006, : 1211 - +