Experimental Study on Utilization of Heat Pipe Heat Exchanger for Energy Conservation of Air Conditioning System in a Hospitals and its Techno-Economic Feasibility

被引:4
|
作者
Hakim, Imansyah Ibnu [1 ]
Putra, Nandy [1 ]
Sukarno, Ragil [1 ]
Audi, Muhammad Rifqi [1 ]
Rachman, Fadhil Fuad [1 ]
机构
[1] Univ Indonesia, Dept Mech Engn, Appl Heat Transfer Res Grp, Kampus UI, Depok 16424, Indonesia
关键词
Heat pipe heat exchanger; effectiveness; energy saving; payback periods; WASTE HEAT; HVAC;
D O I
10.1063/5.0014138
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
With its growing economy and population, the need of energy for facilities in Indonesia increases, particularly in a hospital. Energy needs for the air conditioning system in the hospital is very large, so that the effort to use energy efficiently becomes very important. The purpose of this study is to investigate the influence of heat pipe heat exchanger (HPHE) applied to the ducting of air conditioning system to effectiveness and energy recovery. This study will also focus on economic analysis to determine the feasibility of HPHE applied in the air conditioning system. The HPHE used in this research is varied in 1, 2, and 3 modules which consists of 12 heat pipes each module are arranged in staggered configuration. Air inlet temperature in the evaporator section is varied of 28, 30, 35, and 40 degrees C, and air inlet velocity varied of 1.5, 2.0, 2.5 m/s. Material, production, and installation cost of HPHE in 1, 2, and 3 modules are calculated and compared with electricity energy saving to know how long of time to recover the investment of HPHE. The results show that the maximum effectiveness of 40.25 % obtained at 3 modules of HPHE, with air inlet temperature of 40 degrees C, and the inlet air velocity of 1.5 m/s. It is also found that a maximum heat recovery of 400.54 Watts and annual cost saving of IDR 1.410.205 per year is found when the inlet temperature of 40 degrees C, air velocity of 2.5 m/s, and with three modules installed into the ducting of the air conditioning system. With energy saving of IDR 723,190 per year on air inlet temperature 40 degrees C and air velocity 2.5 m/s, HPHE with 1 module has a shorter payback period than HPHE with 2 and 3-modules.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Theoretical and experimental investigation of a heat pipe heat exchanger for energy recovery of exhaust air
    Ali, Sahar M.
    Sarsam, Wail S.
    HEAT TRANSFER, 2022, 51 (04) : 3600 - 3619
  • [22] THERMAL PERFORMANCE ENHANCEMENT OF HEAT PIPE HEAT EXCHANGER IN THE AIR-CONDITIONING SYSTEM BY USING NANOFLUID
    Abdallah, Ayad S.
    Yasin, Nabil Jamil
    Ameen, Hani Aziz
    FRONTIERS IN HEAT AND MASS TRANSFER, 2022, 18
  • [23] THE EXPERIMENTAL RESEARCH OF MICROCHANNEL HEAT EXCHANGER ON PACKAGED AIR CONDITIONING SYSTEM
    Wang Ying
    Zhang Ziqi
    Chen Jiang-ping
    Ge Fang-gen
    Wang Feng
    Li Feng
    11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 600 - 606
  • [24] Experimental performance and parametric analysis of heat pipe heat exchanger for air conditioning application integrated with evaporative cooling
    Jadhav, Tushar S.
    Lele, Mandar M.
    HEAT AND MASS TRANSFER, 2017, 53 (11) : 3287 - 3293
  • [25] Experimental performance and parametric analysis of heat pipe heat exchanger for air conditioning application integrated with evaporative cooling
    Tushar S. Jadhav
    Mandar M. Lele
    Heat and Mass Transfer, 2017, 53 : 3287 - 3293
  • [26] Investigation of heat pipe heat exchanger effectiveness and energy saving in air conditioning systems using silver nanofluid
    Firouzfar, E.
    Soltanieh, M.
    Noie, S. H.
    Saidi, M. H.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2012, 9 (04) : 587 - 594
  • [27] Investigation of heat pipe heat exchanger effectiveness and energy saving in air conditioning systems using silver nanofluid
    E. Firouzfar
    M. Soltanieh
    S. H. Noie
    M. H. Saidi
    International Journal of Environmental Science and Technology, 2012, 9 : 587 - 594
  • [28] Experimental study on heat recovery and utilization of air conditioning condensate
    Chen, Xiaoyu
    Liang, Yiting
    Yin, Linjian
    Cheng, Haifeng
    ENERGY REPORTS, 2024, 12 : 4004 - 4015
  • [29] Performance Study of Double Pipe Internal Heat Exchanger in R-410a Air Conditioning System
    Djuanda
    INTERNATIONAL CONFERENCE ON THERMAL SCIENCE AND TECHNOLOGY (ICTST) 2017, 2018, 1984
  • [30] Techno-economic feasibility evaluation of air to water heat pump retrofit in the Canadian housing stock
    Asaee, S. Rasoul
    Ugursal, V. Ismet
    Beausoleil-Morrison, Ian
    APPLIED THERMAL ENGINEERING, 2017, 111 : 936 - 949