Performance analysis of internal heat exchanger in air conditioning system was conducted in this research. The use of internal heat exchanger aimed to improve the performance of the air conditioning system. The air conditioning system used was R-410a, which was the replacement of R-22 system. Internal heat exchanger type used in this research was double pipe heat exchanger with opposite flow direction. The study was conducted by testing the air conditioning system using internal heat exchanger and standard system without internal heat exchanger. Temperature and pressure measurements were made at several points on the test platform. The amount of power consumption required by the system was also measured. The test results showed that the use of internal heat exchanger increased the COP 9.02% higher compared to the system without using an internal heat exchanger.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Statistical optimization of Closed Loop Pulsating Heat Pipe parameters with R-410a and nanorefrigerant in air conditioning applications
    Veerasamy, Aruna
    Balakrishnan, Kanimozhi
    Abdul Razack, Sirajunnisa
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2021,
  • [2] Dynamic characteristics of a R-410A split air-conditioning system
    Kim, MH
    Bullard, CW
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (07): : 652 - 659
  • [3] Optimizing the performance of the air conditioning system using an innovative heat pipe heat exchanger
    Eidan, Adel A.
    Alshukri, Mohammed J.
    Al-fahham, Mohamed
    AlSahlani, Assaad
    Abdulridha, Dhurgham M.
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 26
  • [4] Performance of R-410A Alternative Refrigerants in a Reciprocating Compressor Designed for Air Conditioning Applications
    Shrestha, Som S.
    Lenz, James R.
    Vineyard, Edward
    Mumpower, Kevin
    2016 ASHRAE ANNUAL CONFERENCE PAPERS, 2016,
  • [5] Effect of Flow Direction for the Heat Transfer Performance of Refrigerant R-410A Evaporation in a Plate Heat Exchanger
    Yang, Chien-Yuh
    Lin, Yueh-Hung
    Lin, Fu-Chen
    HEAT TRANSFER ENGINEERING, 2013, 34 (13) : 1133 - 1139
  • [6] A study of secondary heat recovery efficiency of a heat pipe heat exchanger air conditioning system
    Wang, Haitao
    Zhou, Shunbao
    Wei, Zhongshi
    Wang, Ren
    ENERGY AND BUILDINGS, 2016, 133 : 206 - 216
  • [7] Experimental Study of an Internal Heat Exchanger Influence on R134a Automobile Air Conditioning System
    Bahrami, Selman
    Beigi, Hasan Mohammad
    Sabour, Mohammad Hosein
    TRENDS IN AUTOMOTIVE RESEARCH, 2012, 165 : 145 - +
  • [8] Experimental study on R-410a evaporation heat transfer characteristics in oblong shell and plate heat exchanger
    Kim, In-Kwan
    Park, Jae-Hong
    Kwon, Yong-Ha
    Kim, Young-Soo
    HEAT TRANSFER ENGINEERING, 2007, 28 (07) : 633 - 639
  • [9] The Effects of the Condenser Pressure Drop on the Cooling Performance of an Air Conditioning Unit using R-410A
    Stmardi, Cecep
    Markus
    Setyawan, Andriyanto
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON THERMOFLUIDS 2017 (THERMOFLUID 2017), 2018, 2001
  • [10] THERMAL PERFORMANCE ENHANCEMENT OF HEAT PIPE HEAT EXCHANGER IN THE AIR-CONDITIONING SYSTEM BY USING NANOFLUID
    Abdallah, Ayad S.
    Yasin, Nabil Jamil
    Ameen, Hani Aziz
    FRONTIERS IN HEAT AND MASS TRANSFER, 2022, 18