Performance analysis of internal heat exchanger in air conditioning system was conducted in this research. The use of internal heat exchanger aimed to improve the performance of the air conditioning system. The air conditioning system used was R-410a, which was the replacement of R-22 system. Internal heat exchanger type used in this research was double pipe heat exchanger with opposite flow direction. The study was conducted by testing the air conditioning system using internal heat exchanger and standard system without internal heat exchanger. Temperature and pressure measurements were made at several points on the test platform. The amount of power consumption required by the system was also measured. The test results showed that the use of internal heat exchanger increased the COP 9.02% higher compared to the system without using an internal heat exchanger.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Exergetic Investigation of a R1234yf Automotive Air Conditioning System with Internal Heat Exchanger
    Direk, M.
    Mert, M. S.
    Yuksel, F.
    Kelesoglu, A.
    INTERNATIONAL JOURNAL OF THERMODYNAMICS, 2018, 21 (02) : 103 - 109
  • [22] Spatialization of Chinese R-410A emissions from the room air-conditioning sector
    Pengcheng Wu
    Li Zhang
    Bo Yao
    Bofeng Cai
    Yifang Zhu
    Hui Liu
    Pengling Wang
    Lisha Liu
    Yanwei Dou
    Han Yan
    Yijun Liu
    Zixuan Xie
    Lingyun Pang
    Libin Cao
    Yimeng Ren
    Xin Bo
    Environment, Development and Sustainability, 2023, 25 : 5263 - 5281
  • [23] Analysis of system performance losses due to the reversing valve for a heat pump using R-410a
    AAON, Inc, Tulsa, United States
    ASHRAE Trans, (PART 1/-):
  • [24] Analysis of enthalpy change with/without a heat pipe heat exchanger in a tropical air conditioning system
    Yau, Y. H.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2006, 30 (15) : 1251 - 1263
  • [25] Evaporation heat transfer and pressure drop of refrigerant R-410A flow in a vertical plate heat exchanger
    Hsieh, YY
    Lin, TF
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2003, 125 (05): : 852 - 857
  • [26] Development of Energy Efficient R-134a Automotive Air Conditioning System Using Internal Heat Exchanger
    Desai, Avinash. D.
    Sapali, S. N.
    Garikipati, Parthasarathi. V.
    WORLD CONGRESS ON ENGINEERING, WCE 2011, VOL III, 2011, : 2250 - 2255
  • [27] Saturated flow boiling heat transfer and pressure drop of refrigerant R-410A in a vertical plate heat exchanger
    Hsieh, YY
    Lin, TF
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2002, 45 (05) : 1033 - 1044
  • [28] A desiccant evaporative air conditioning performance improvement using heat pipe heat exchanger as a heat recovery device
    Alblawi, Adel
    CASE STUDIES IN THERMAL ENGINEERING, 2025, 69
  • [29] Optimization of the heat exchanger of an air conditioning system
    Chichindaev, A
    Dyachenko, Y
    KORUS 2003: 7TH KOREA-RUSSIA INTERNATIONAL SYMPOSIUM ON SCIENCE AND TECHNOLOGY, VOL 1 PROCEEDINGS: MACHINE PARTS AND MATERIALS PROCESSING, 2003, : 255 - 259
  • [30] Transient Characteristics of Split Air-Conditioning Systems Using R-22 and R-410A as Refrigerants
    Kapadia, R. G.
    Jain, Sanjeev
    Agarwal, R. S.
    HVAC&R RESEARCH, 2009, 15 (03): : 617 - 649