The Effects of the Condenser Pressure Drop on the Cooling Performance of an Air Conditioning Unit using R-410A

被引:0
|
作者
Stmardi, Cecep [1 ]
Markus [1 ]
Setyawan, Andriyanto [1 ]
机构
[1] Politekn Negeri Bandung, Refrigerat & Air Conditioning Dept, Bandung 40012, Indonesia
关键词
pressure drop; evaporator capacity; condenser capacity; COP;
D O I
10.1063/1.5049966
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The effect of pressure drop in the condenser of an air conditioning unit with R410 was simulated under constant swept volume of the compressor. Evaporating temperature and evaporating pressure increase as the pressure drop increases. It causes the decrease of refrigerant density, refrigerant mass flow rate, and refrigeration effect. The enthalpy difference across condenser and compressor, however, increase with the increasing pressure drop. This gives the reduction of evaporator capacity by 25% for pressure drop of 200 kPa. For the same range of pressure drop, the condenser capacity is reduced by 19%, COP is reduced by 27%, and the compressor capacity is almost constant.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Modeling and experimental study on the performance of an inverter air conditioner using R-410A with evaporatively cooled condenser
    Sarntichartsak, Pongsakorn
    Thepa, Sirichai
    APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) : 597 - 610
  • [2] Performance of R-410A Alternative Refrigerants in a Reciprocating Compressor Designed for Air Conditioning Applications
    Shrestha, Som S.
    Lenz, James R.
    Vineyard, Edward
    Mumpower, Kevin
    2016 ASHRAE ANNUAL CONFERENCE PAPERS, 2016,
  • [3] Dynamic characteristics of a R-410A split air-conditioning system
    Kim, MH
    Bullard, CW
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (07): : 652 - 659
  • [4] Performance Study of Double Pipe Internal Heat Exchanger in R-410a Air Conditioning System
    Djuanda
    INTERNATIONAL CONFERENCE ON THERMAL SCIENCE AND TECHNOLOGY (ICTST) 2017, 2018, 1984
  • [5] Testing and analysis of retrofitting R-22 air conditioning unit with alternatives R-407C and R-410A
    Mohamed, Mousa M.
    Hanafy, Ahmed E.
    AEJ - Alexandria Engineering Journal, 2004, 43 (04): : 417 - 431
  • [6] Two-phase pressure drop of air-water and R-410A in small horizontal tubes
    Chen, IY
    Yang, KS
    Chang, YJ
    Wang, CC
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2001, 27 (07) : 1293 - 1299
  • [7] Transient Characteristics of Split Air-Conditioning Systems Using R-22 and R-410A as Refrigerants
    Kapadia, R. G.
    Jain, Sanjeev
    Agarwal, R. S.
    HVAC&R RESEARCH, 2009, 15 (03): : 617 - 649
  • [8] Two-phase pressure drop of R-410A in horizontal smooth minichannels
    Choi, Kwang-Il
    Pamitran, A. S.
    Oh, Chun-Young
    Oh, Jong-Taek
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (01): : 119 - 129
  • [9] BOILING HEAT TRANSFER AND PRESSURE DROP OF R-410A AND R-134A IN HORIZONTAL MINICHANNELS
    Pamitran, A. S.
    Choi, Kwang-Il
    Oh, Jong-Taek
    Oh, Hoo-Kyu
    Hrnjak, Pega
    ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 149 - 154
  • [10] CONDENSATION HEAT TRANSFER AND PRESSURE DROP OF R-410A IN FLAT ALUMINUM MULTIPORT TUBES
    Kim, Nae-Hyun
    Go, Min-Geon
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 912 - 916