Experimental Study on Utilization of Heat Pipe Heat Exchanger for Energy Conservation of Air Conditioning System in a Hospitals and its Techno-Economic Feasibility

被引:4
|
作者
Hakim, Imansyah Ibnu [1 ]
Putra, Nandy [1 ]
Sukarno, Ragil [1 ]
Audi, Muhammad Rifqi [1 ]
Rachman, Fadhil Fuad [1 ]
机构
[1] Univ Indonesia, Dept Mech Engn, Appl Heat Transfer Res Grp, Kampus UI, Depok 16424, Indonesia
关键词
Heat pipe heat exchanger; effectiveness; energy saving; payback periods; WASTE HEAT; HVAC;
D O I
10.1063/5.0014138
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
With its growing economy and population, the need of energy for facilities in Indonesia increases, particularly in a hospital. Energy needs for the air conditioning system in the hospital is very large, so that the effort to use energy efficiently becomes very important. The purpose of this study is to investigate the influence of heat pipe heat exchanger (HPHE) applied to the ducting of air conditioning system to effectiveness and energy recovery. This study will also focus on economic analysis to determine the feasibility of HPHE applied in the air conditioning system. The HPHE used in this research is varied in 1, 2, and 3 modules which consists of 12 heat pipes each module are arranged in staggered configuration. Air inlet temperature in the evaporator section is varied of 28, 30, 35, and 40 degrees C, and air inlet velocity varied of 1.5, 2.0, 2.5 m/s. Material, production, and installation cost of HPHE in 1, 2, and 3 modules are calculated and compared with electricity energy saving to know how long of time to recover the investment of HPHE. The results show that the maximum effectiveness of 40.25 % obtained at 3 modules of HPHE, with air inlet temperature of 40 degrees C, and the inlet air velocity of 1.5 m/s. It is also found that a maximum heat recovery of 400.54 Watts and annual cost saving of IDR 1.410.205 per year is found when the inlet temperature of 40 degrees C, air velocity of 2.5 m/s, and with three modules installed into the ducting of the air conditioning system. With energy saving of IDR 723,190 per year on air inlet temperature 40 degrees C and air velocity 2.5 m/s, HPHE with 1 module has a shorter payback period than HPHE with 2 and 3-modules.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] EXPERIMENTAL STUDY OF MULTI-FIN HEAT PIPE HEAT EXCHANGER FOR ENERGY EFFICIENCY IN OPERATING ROOM AIR SYSTEMS
    Muhammaddiyah, Syahrul
    Winarta, Adi
    Putra, Nandy
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2018, 9 (02) : 422 - 429
  • [32] THE APPLICATION OF U-SHAPE HEAT PIPE HEAT EXCHANGER TO REDUCE RELATIVE HUMIDITY FOR ENERGY CONSERVATION IN HEATING, VENTILATION, AND AIR CONDITIONING (HVAC) SYSTEMS
    Kusumah, Aliefka Satria
    Hakim, Imansyah Ibnu
    Sukarno, Ragil
    Rachman, Fadhil Fuad
    Putra, Nandy
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2019, 10 (06) : 1202 - 1210
  • [33] Experimental study on a novel air conditioning system for deep cascade utilization of waste heat
    Cheng, Xiaosong
    Yin, Yonggao
    Guo, Yuwen
    Zhou, Weihang
    APPLIED THERMAL ENGINEERING, 2022, 200
  • [34] Thermodynamic and techno-economic analysis of heat pipe ETC water heating system for Indian composite climateAn experimental approach
    K. Chopra
    V. V. Tyagi
    A. K. Pandey
    Journal of Thermal Analysis and Calorimetry, 2020, 139 : 1395 - 1407
  • [35] Thermodynamic and techno-economic analysis of heat pipe ETC water heating system for Indian composite climate An experimental approach
    Chopra, K.
    Tyagi, V. V.
    Pandey, A. K.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 139 (02) : 1395 - 1407
  • [36] Techno-economic evaluation of a ventilation system assisted with exhaust air heat recovery, electrical heater and solar energy
    Ozyogurtcu, Gamze
    Mobedi, Moghtada
    Ozerdem, Baris
    ENERGY AND BUILDINGS, 2014, 72 : 17 - 23
  • [37] Techno-economic versus energy optimization of natural gas liquefaction processes with different heat exchanger technologies
    Son, Heechang
    Austbo, Bjorn
    Gundersen, Truls
    Hwang, Jihyun
    Lim, Youngsub
    ENERGY, 2022, 245
  • [38] Experimental evaluation of an earth-to-air heat exchanger and air source heat pump hybrid indoor air conditioning system
    Guo, Xin
    Wei, Haibin
    He, Xiao
    Du, Jinhui
    Yang, Dong
    ENERGY AND BUILDINGS, 2022, 256
  • [39] Experimental and Performance Study of Diesel Engine Using Inlet Preheated Air by Heat Pipe Heat Exchanger
    Ramkumar, P.
    Sivasubramanian, M.
    Ramasamy, S.
    Vivek, C. M.
    Latha, P.
    2ND INTERNATIONAL CONFERENCE ON SMART SUSTAINABLE MATERIALS AND TECHNOLOGIES, VOL 1, ICSSMT 2023, 2024, : 211 - 218
  • [40] Experimental investigation of wraparound loop heat pipe heat exchanger used in energy efficient air handling units
    Jouhara, Hussam
    Meskimmon, Richard
    ENERGY, 2010, 35 (12) : 4592 - 4599