3D characterization of small megavoltage radiation fields using an optical CT scanner with ferrous xylenol orange gels

被引:0
|
作者
McNiven, A. [1 ]
Babic, S. [1 ]
Jordan, K. [1 ]
Battista, J. [1 ]
机构
[1] Univ Western Ontario, London Hlth Sci Ctr, London Reg Canc Program, Dept Med Biophys, London, ON, Canada
关键词
D O I
10.1118/1.2760648
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the feasibility of using a 3D dosimetry system consisting of a radiochromic ferrous xylenol orange (FX) gel and a prototype commercial cone beam optical‐CT scanning system (Vista™, Modus Medical Devices, Inc., London, ON) to dosimetrially characterize small megavoltage photon fields. Method and Materials: An FXG gel was irradiated using 6MV x‐ray fields (30, 10 and 5mm diameter) produced via custom stereotactic collimators mounted on a Varian Clinac 2100EX accelerator. Measurements were also completed using radiochromic (Gafchromic EBT) and radiographic (Kodak EDR2) film, and a Exradin A1SL ion chamber for comparison purposes. The gel was optically CT scanned 10, 20, 30 and 40 minutes post‐irradiation to assess the effects of xylenol orange/ferric ion complex diffusion in gel. Lateral dose profiles and percentage depth dose (PDD) curves were extracted from the 3D image data sets for analysis. Results: FX gels together with fast optical CT scanning allows for the measurement of all dosimetric parameters required as pencil beam input for treatment planning systems in a single irradiation. The experimental set‐up is simple, and the gel allows for dose measurements in a tissue‐equivalent and energy‐independent medium. Lateral beam profiles as measured in the FXG gel matched those measured using both types of film within 2 mm. PDD curves measured with gel and ion chamber were also in good agreement (within 3 mm) up to 65mm depth. Conclusion: The radiochromic FX gel and fast optical CT scanner is a promising dosimetry system for the characterization of small x‐ray fields for the purposes of commissioning treatment planning systems. The advantage is that a full 3D data set can be acquired quickly and efficiently. Conflict of Interest: Two of the authors (KJ and JB) have a licensing agreement with Modus Medical Devices, Inc. for the commercialization of the Vista™ scanner. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2401 / 2401
页数:1
相关论文
共 50 条
  • [1] RapidArc Dose Verification Using Ferrous Xylenol-Orange Gels and Optical CT
    Babic, S.
    Hajdok, G.
    Jordan, K.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [2] Three-dimensional dosimetry of small megavoltage radiation fields using radiochromic gels and optical CT scanning
    Babic, Steven
    McNiven, Andrea
    Battista, Jerry
    Jordan, Kevin
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (08): : 2463 - 2481
  • [3] An intercomparison of RPC verified IMRT plans with ferrous xylenol orange gels and optical CT scanners
    Babic, S.
    Battista, J.
    Jordan, K.
    MEDICAL PHYSICS, 2007, 34 (06) : 2417 - 2417
  • [4] Optical CT scanner for in-air readout of gels for external radiation beam 3D dosimetry
    Ramm, Daniel
    Rutten, Thomas P.
    Shepherd, Justin
    Bezak, Eva
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (12): : 3853 - 3868
  • [5] Comparison of 3D dose measurements in ferrous xylenol orange gels with mapcheck diode array and Pinnacle3 dose calculations
    Jordan, K.
    Babic, S.
    Chen, J.
    Battista, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2428 - 2428
  • [6] Optical CT reconstruction of 3D dose distributions using the ferrous-benzoic-xylenol (FBX) gel dosimeter
    Kelly, RG
    Jordan, KJ
    Battista, JJ
    MEDICAL PHYSICS, 1998, 25 (09) : 1741 - 1750
  • [7] Accuracy Comparison of the Optical 3D Scanner and CT Scanner
    Mendricky, Radomir
    Sobotka, Jiri
    MANUFACTURING TECHNOLOGY, 2020, 20 (06): : 791 - 801
  • [8] Optimization of the scintillation detector in a combined 3D megavoltage CT scanner and portal imager
    Mosleh-Shirazi, MA
    Swindell, W
    Evans, PM
    MEDICAL PHYSICS, 1998, 25 (10) : 1880 - 1890
  • [9] Cone beam optical CT scanner for 3D dosimetry
    Miller, J
    Adamovics, J
    Dietrich, J
    MEDICAL PHYSICS, 2005, 32 (06) : 2138 - 2138
  • [10] Simulated design optimization of a prototype solid tank optical CT scanner for 3D radiation dosimetry
    Ogilvy, A.
    Collins, S.
    Hare, W.
    Hilts, M.
    Tuokko, T.
    Deardon, R.
    Jirasek, A.
    11TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, IC3DDOSE, 2022, 2167