3D characterization of small megavoltage radiation fields using an optical CT scanner with ferrous xylenol orange gels

被引:0
|
作者
McNiven, A. [1 ]
Babic, S. [1 ]
Jordan, K. [1 ]
Battista, J. [1 ]
机构
[1] Univ Western Ontario, London Hlth Sci Ctr, London Reg Canc Program, Dept Med Biophys, London, ON, Canada
关键词
D O I
10.1118/1.2760648
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the feasibility of using a 3D dosimetry system consisting of a radiochromic ferrous xylenol orange (FX) gel and a prototype commercial cone beam optical‐CT scanning system (Vista™, Modus Medical Devices, Inc., London, ON) to dosimetrially characterize small megavoltage photon fields. Method and Materials: An FXG gel was irradiated using 6MV x‐ray fields (30, 10 and 5mm diameter) produced via custom stereotactic collimators mounted on a Varian Clinac 2100EX accelerator. Measurements were also completed using radiochromic (Gafchromic EBT) and radiographic (Kodak EDR2) film, and a Exradin A1SL ion chamber for comparison purposes. The gel was optically CT scanned 10, 20, 30 and 40 minutes post‐irradiation to assess the effects of xylenol orange/ferric ion complex diffusion in gel. Lateral dose profiles and percentage depth dose (PDD) curves were extracted from the 3D image data sets for analysis. Results: FX gels together with fast optical CT scanning allows for the measurement of all dosimetric parameters required as pencil beam input for treatment planning systems in a single irradiation. The experimental set‐up is simple, and the gel allows for dose measurements in a tissue‐equivalent and energy‐independent medium. Lateral beam profiles as measured in the FXG gel matched those measured using both types of film within 2 mm. PDD curves measured with gel and ion chamber were also in good agreement (within 3 mm) up to 65mm depth. Conclusion: The radiochromic FX gel and fast optical CT scanner is a promising dosimetry system for the characterization of small x‐ray fields for the purposes of commissioning treatment planning systems. The advantage is that a full 3D data set can be acquired quickly and efficiently. Conflict of Interest: Two of the authors (KJ and JB) have a licensing agreement with Modus Medical Devices, Inc. for the commercialization of the Vista™ scanner. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2401 / 2401
页数:1
相关论文
共 50 条
  • [41] OPTICAL SCANNER AND 3D PRINTER TECHNOLOGY TO MANUFACTURE RIGID BOLUS FOR RADIATION TREATMENT: AN INNOVATIVE APPROACH
    Sharma, Ankur
    Dubey, Arbind
    Rickey, Daniel
    Harris, Chad
    Sasaki, David
    Alpuche, Jorge
    Butler, Jim
    Leylek, Ahmet
    Johnson, Kate
    McCurdy, Boyd
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 : S25 - S26
  • [42] 3D characterization of desiccation cracking in clayey soils using a structured light scanner
    Zhuo, Zhuang
    Zhu, Cheng
    Tang, Chao-Sheng
    Xu, Hao
    Shi, Xiangchao
    Mark, Vail
    ENGINEERING GEOLOGY, 2022, 299
  • [43] EUV patterning Characterization Using a 3D Mask Simulation and Field EUV Scanner
    Park, Jun-Taek
    Hyun, Yoon-Suk
    Lim, Chang-Moon
    Eom, Tae-Seung
    Koo, Sunyoung
    Park, Sarohan
    Kim, Suk-Kyun
    Ban, Kuen-Do
    Yang, Hyun-Jo
    Oh, Chang-Il
    Nam, Byoung-Ho
    Kim, Chang-Reol
    Kim, HyeongSoo
    Moon, Seung-Chan
    Park, Sungki
    ALTERNATIVE LITHOGRAPHIC TECHNOLOGIES, 2009, 7271
  • [44] A Method to Obtain Orange Crop Geometry Information Using a Mobile Terrestrial Laser Scanner and 3D Modeling
    Colaco, Andre F.
    Trevisan, Rodrigo G.
    Molin, Jose P.
    Rosell-Polo, Joan R.
    Escola, Alexandre
    REMOTE SENSING, 2017, 9 (08)
  • [45] Detection and characterization of very small cerebral aneurysms by using 2D and 3D helical CT angiography
    Villablanca, JP
    Jahan, R
    Hooshi, P
    Lim, S
    Duckwiler, G
    Patel, A
    Sayre, J
    Martin, N
    Frazee, J
    Bentson, J
    Vifiuela, F
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2002, 23 (07) : 1187 - 1198
  • [46] A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results
    Doran, SJ
    Koerkamp, KK
    Bero, MA
    Jenneson, P
    Morton, EJ
    Gilboy, WB
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (12): : 3191 - 3213
  • [47] Fast laser scanning optical-CT apparatus for 3D radiation dosimetry
    Krstajic, Nikola
    Doran, Simon J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (11): : N257 - N263
  • [48] Aggregate Morphological Characterization with 3D Optical Scanner versus X-Ray Computed Tomography
    Liu, Yu
    Gong, Fangyuan
    You, Zhanping
    Wang, Hainian
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2018, 30 (01)
  • [49] Optical Characterization of Heliostats using Multiple 3D Geometry Characterization Sensors
    Bonanos, Aristides M.
    Faka, Marina
    Abate, Dante
    Hermon, Sorin
    Blanco, Manuel J.
    INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS (SOLARPACES 2017), 2018, 2033
  • [50] Effect of light source instability on uniformity of 3D reconstructions from a cone beam optical CT scanner
    J. Begg
    M. L. Taylor
    L. Holloway
    T. Kron
    R. D. Franich
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 791 - 798