3D characterization of small megavoltage radiation fields using an optical CT scanner with ferrous xylenol orange gels

被引:0
|
作者
McNiven, A. [1 ]
Babic, S. [1 ]
Jordan, K. [1 ]
Battista, J. [1 ]
机构
[1] Univ Western Ontario, London Hlth Sci Ctr, London Reg Canc Program, Dept Med Biophys, London, ON, Canada
关键词
D O I
10.1118/1.2760648
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the feasibility of using a 3D dosimetry system consisting of a radiochromic ferrous xylenol orange (FX) gel and a prototype commercial cone beam optical‐CT scanning system (Vista™, Modus Medical Devices, Inc., London, ON) to dosimetrially characterize small megavoltage photon fields. Method and Materials: An FXG gel was irradiated using 6MV x‐ray fields (30, 10 and 5mm diameter) produced via custom stereotactic collimators mounted on a Varian Clinac 2100EX accelerator. Measurements were also completed using radiochromic (Gafchromic EBT) and radiographic (Kodak EDR2) film, and a Exradin A1SL ion chamber for comparison purposes. The gel was optically CT scanned 10, 20, 30 and 40 minutes post‐irradiation to assess the effects of xylenol orange/ferric ion complex diffusion in gel. Lateral dose profiles and percentage depth dose (PDD) curves were extracted from the 3D image data sets for analysis. Results: FX gels together with fast optical CT scanning allows for the measurement of all dosimetric parameters required as pencil beam input for treatment planning systems in a single irradiation. The experimental set‐up is simple, and the gel allows for dose measurements in a tissue‐equivalent and energy‐independent medium. Lateral beam profiles as measured in the FXG gel matched those measured using both types of film within 2 mm. PDD curves measured with gel and ion chamber were also in good agreement (within 3 mm) up to 65mm depth. Conclusion: The radiochromic FX gel and fast optical CT scanner is a promising dosimetry system for the characterization of small x‐ray fields for the purposes of commissioning treatment planning systems. The advantage is that a full 3D data set can be acquired quickly and efficiently. Conflict of Interest: Two of the authors (KJ and JB) have a licensing agreement with Modus Medical Devices, Inc. for the commercialization of the Vista™ scanner. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2401 / 2401
页数:1
相关论文
共 50 条
  • [21] Fricke-Xylenol orange-Gelatin gel characterization with dual wavelength cone-beam optical CT scanner for applications in stereotactic and dynamic radiotherapy
    Rousseau, Alice
    Stien, Christel
    Bordy, Jean-Marc
    Blideanu, Valentin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 97 : 1 - 12
  • [22] Evaluation of polymer gels and laser-beam optical CT scanner as a 3-D dosimeter for IMRT
    Wuu, C
    Xu, Y
    Maryanski, M
    MEDICAL PHYSICS, 2003, 30 (06) : 1349 - 1349
  • [23] 3D IN VIVO DOSIMETRY USING MEGAVOLTAGE CONE-BEAM CT AND EPID DOSIMETRY
    van Elmpt, Wouter
    Nusten, Sebastiaan
    Petit, Steven
    Munheer, Ben
    Lambin, Philippe
    Dekker, Andre
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (05): : 1580 - 1587
  • [24] Characterization of a parallel-beam CCD optical-CT apparatus for 3D radiation dosimetry
    Krstajic, Nikola
    Doran, Simon J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (13): : 3693 - 3713
  • [25] Controlling sensitivity and stability of ferrous-xylenol orange-gelatin 3D gel dosimeters by doping with phenanthroline-type ligands and glyoxal
    Penev, Kalin I.
    Mequanint, Kibret
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (06): : 1823 - 1838
  • [26] Using optical NIR handheld scanner for close range 3d mapping
    Wrona, Maciej
    9TH INTERNATIONAL CONFERENCE ENVIRONMENTAL ENGINEERING (9TH ICEE) - SELECTED PAPERS, 2014,
  • [27] Quantifying wear depth in hip prostheses using a 3D optical scanner
    Hollar, Katherine A.
    Ferguson, Daniel S.
    Everingham, John B.
    Helms, Jillian L.
    Warburton, Kevin J.
    Lujan, Trevor J.
    WEAR, 2018, 394 : 195 - 202
  • [28] Development of 3D Dosimetry System using Polymer Gel (TENOMAG) and Optical-CT Scanner in Prostate IMRT
    Lee, S.
    Yi, J.
    Park, J.
    Cho, S.
    Shim, J.
    Chang, K.
    Cao, Y.
    Lee, S.
    Huh, H.
    Kim, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S748 - S748
  • [29] Assessing the fit of 3D printed bolus from CT, optical scanner and photogrammetry methods
    Maxwell, S. K.
    Charles, P. H.
    Cassim, N.
    Kairn, T.
    Crowe, S. B.
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (02) : 601 - 607
  • [30] Assessing the fit of 3D printed bolus from CT, optical scanner and photogrammetry methods
    S. K. Maxwell
    P. H. Charles
    N. Cassim
    T. Kairn
    S. B. Crowe
    Physical and Engineering Sciences in Medicine, 2020, 43 : 601 - 607