Non-Rigid Respiratory Motion Correction for 4D Gated PET Sinogram Data

被引:0
|
作者
Feng, Tao [1 ]
Tsui, Benjamin M. W. [2 ]
机构
[1] Johns Hopkins Univ, Dept Elect & Comp Engn, 3400 N Charles St, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ Hosp, Dept Radiol, Baltimore, MD 21287 USA
来源
2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2013年
关键词
SIMULATION; RECONSTRUCTION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Respiratory motion is one image degradation factor that affects the resolution and may cause artifacts in PET imaging. Respiratory gating technique is able to reduce the blurring effects but results in higher noise level. Conventional motion correction methods that model motion effects during or after image reconstruction not only increases reconstruction time, but also requires a gated or blurred attenuation map to reduce motion artifacts. This paper addresses the respiratory motion correction on sinogram data before reconstruction using a non-rigid motion model. It has the potential to reduce reconstruction time, and does not require gated attenuation maps.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Generating 4D CT in respiratory gated 3D PET/CT studies
    Dawood, Mohammad
    Buether, Florian
    Schober, Otmar
    Schaefers, Michael
    Schaefers, Klaus
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [42] Improved Motion Correction in SPECT Imaging Using a Non-rigid Motion Model
    Gu, Songxiang
    McNamara, Joseph E.
    Joyeeta, Mitra
    Johnson, Karen
    Gifford, Howard
    Pretorius, Hendrik
    Sklyar, Andrey V.
    Gennert, Michael A.
    King, Michael A.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3242 - 3246
  • [43] Non-rigid spatio-temporal alignment of 4D cardiac MR images
    Perperidis, D
    Rao, A
    Mohiaddin, R
    Rueckert, D
    BIOMEDICAL IMAGE REGISTRATION, 2003, 2717 : 191 - 200
  • [44] 4-D PET joint image reconstruction/non-rigid motion estimation with limited MRI prior information
    Alexandre Bousse
    Jieqing Jiao
    Kjell Erlandsson
    Luis Pizarro
    Kris Thielemans
    Dave Atkinson
    Sébastien Ourselin
    Simon Arridge
    Brian Hutton
    EJNMMI Physics, 1 (Suppl 1)
  • [45] Whole-body continuous-bed-motion PET list-mode reconstruction with non-rigid event-by-event respiratory motion correction
    Lu, Yihuan
    Fontaine, Kathryn
    Gallezot, Jean-Dominique
    Mulnix, Tim
    Panin, Vladimir
    Jones, Judson
    Casey, Michael
    Carson, Richard
    Liu, Chi
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [46] Usefulness of 4D PET/CT imaging in lung lesions with respiratory gated scan
    Jinnouchi, S.
    Tateno, R.
    Ueno, I.
    Tanabe, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S318 - S318
  • [47] Digital anthropomorphic phantoms of non-rigid human respiratory and voluntary body motion for investigating motion correction in emission imaging
    Koenik, Arda
    Connolly, Caitlin M.
    Johnson, Karen L.
    Dasari, Paul
    Segars, Paul W.
    Pretorius, P. H.
    Lindsay, Clifford
    Dey, Joyoni
    King, Michael A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (14): : 3669 - 3682
  • [48] 4D CT for respiratory gated attenuation corrections in canine cardiac PET imaging
    Cook, Russell
    Carnes, Greg
    Lee, Ting-Yim
    Wells, R. Glenn
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2408 - 2412
  • [49] Evaluation of Respiratory Motion Impact on 3D and 4D PET Imaging
    Cui, Y.
    Bowsher, J.
    Cai, J.
    Yin, F. F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E553 - E553
  • [50] Expectation maximization reconstruction of PET image with non-rigid motion compensation
    Qiao, Feng
    Clark, John W., Jr.
    Pan, Tinsu
    Mawlawi, Osama
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 4453 - 4456