Non-Rigid Respiratory Motion Correction for 4D Gated PET Sinogram Data

被引:0
|
作者
Feng, Tao [1 ]
Tsui, Benjamin M. W. [2 ]
机构
[1] Johns Hopkins Univ, Dept Elect & Comp Engn, 3400 N Charles St, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ Hosp, Dept Radiol, Baltimore, MD 21287 USA
来源
2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2013年
关键词
SIMULATION; RECONSTRUCTION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Respiratory motion is one image degradation factor that affects the resolution and may cause artifacts in PET imaging. Respiratory gating technique is able to reduce the blurring effects but results in higher noise level. Conventional motion correction methods that model motion effects during or after image reconstruction not only increases reconstruction time, but also requires a gated or blurred attenuation map to reduce motion artifacts. This paper addresses the respiratory motion correction on sinogram data before reconstruction using a non-rigid motion model. It has the potential to reduce reconstruction time, and does not require gated attenuation maps.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Fully 4D reconstruction applied to respiratory gated PET acquisitions
    Grotus, Nicolas
    Reader, Andrew J.
    Brinks, Ralph
    Maniawski, Piotr
    Servois, Vincent
    Rosenwald, Jean-Claude
    Giraud, Philippe
    Buvat, Irene
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4401 - +
  • [22] Simultaneous PET-MR acquisition and MR-derived motion fields for correction of non-rigid motion in PET
    Tsoumpas, Charalampos
    Mackewn, Jane E.
    Halsted, Philip
    King, Andrew P.
    Buerger, Christian
    Totman, John J.
    Schaeffter, Tobias
    Marsden, Paul K.
    ANNALS OF NUCLEAR MEDICINE, 2010, 24 (10) : 745 - 750
  • [23] An iterative image reconstruction algorithm for 4D PET/CT incorporating respiratory motion correction
    Lamare, F.
    Ledesma-Carbayo, M.
    Kontaxakis, G.
    Santos, A.
    Jarritt, P.
    Mawlawi, O.
    Le Rest, C. Cheze
    Visvikis, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S147 - S147
  • [24] Motion Correction and Attenuation Correction for Respiratory Gated PET Images
    Bai, Wenjia
    Brady, Michael
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (02) : 351 - 365
  • [25] Event-by-event non-rigid data-driven PET respiratory motion correction methods: comparison of principal component analysis and centroid of distribution
    Ren, Silin
    Lu, Yihuan
    Bertolli, Ottavia
    Thielemans, Kris
    Carson, Richard E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (16):
  • [26] Non rigid respiratory motion correction in whole body PET/MR imaging
    Hadi Fayad
    Holger Schmidt
    Christian Wuerslin
    Dimitris Visvikis
    EJNMMI Physics, 1 (Suppl 1)
  • [27] CONSTRUCTION OF A 4D ATLAS OF THE DEVELOPING BRAIN USING NON-RIGID REGISTRATION
    Serag, Ahmed
    Aljabar, Paul
    Counsell, Serena
    Boardman, James
    Hajnal, Jo V.
    Rueckert, Daniel
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 1532 - 1535
  • [28] 4D numerical observer for lesion detection in respiratory-gated PET
    Lorsakul, Auranuch
    Li, Quanzheng
    Trott, Cathryn M.
    Hoog, Christopher
    Petibon, Yoann
    Ouyang, Jinsong
    Laine, Andrew F.
    El Fakhri, Georges
    MEDICAL PHYSICS, 2014, 41 (10)
  • [29] Highly efficient respiratory gating in coronary MR employing non-rigid retrospective motion correction
    Johannes F Schmidt
    Martin Buehrer
    Peter Boesiger
    Sebastian Kozerke
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [30] Joint estimation of motion and activity concentration for 4D gated PET studies
    Qiao, F.
    Pan, T.
    Clark, J.
    Mawlawi, O.
    MEDICAL PHYSICS, 2006, 33 (06) : 2169 - 2169