Non-Rigid Respiratory Motion Correction for 4D Gated PET Sinogram Data

被引:0
|
作者
Feng, Tao [1 ]
Tsui, Benjamin M. W. [2 ]
机构
[1] Johns Hopkins Univ, Dept Elect & Comp Engn, 3400 N Charles St, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ Hosp, Dept Radiol, Baltimore, MD 21287 USA
来源
2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2013年
关键词
SIMULATION; RECONSTRUCTION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Respiratory motion is one image degradation factor that affects the resolution and may cause artifacts in PET imaging. Respiratory gating technique is able to reduce the blurring effects but results in higher noise level. Conventional motion correction methods that model motion effects during or after image reconstruction not only increases reconstruction time, but also requires a gated or blurred attenuation map to reduce motion artifacts. This paper addresses the respiratory motion correction on sinogram data before reconstruction using a non-rigid motion model. It has the potential to reduce reconstruction time, and does not require gated attenuation maps.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Objective evaluation of the correction by non-rigid registration of abdominal organ motion in low-dose 4D dynamic contrast-enhanced CT
    Piper, Jim
    Ikeda, Yoshihiro
    Fujisawa, Yasuko
    Ohno, Yoshiharu
    Yoshikawa, Takeshi
    O'Neil, Alison
    Poole, Ian
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (06): : 1701 - 1715
  • [32] RETROSPECTIVE CORRECTION OF RIGID AND NON-RIGID MR MOTION ARTIFACTS USING GANS
    Armanious, Karim
    Gatidis, Sergios
    Nikolaou, Konstantin
    Yang, Bin
    Kuestner, Thomas
    2019 IEEE 16TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2019), 2019, : 1550 - 1554
  • [33] Lung motion correction on respiratory gated 3-D PET/CT images
    Dawood, M
    Lang, N
    Jiang, XY
    Schäfers, KP
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (04) : 476 - 485
  • [34] Signal optimization as strategy for non-specific 4D data utilization - An analysis of impact in respiratory gated human PET scans
    Kesner, Adam
    Chung, Jonathan
    Koo, Phillip
    Lynch, David
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [35] Compensating respiratory motion in PET image reconstruction using 4D PET/CT
    Qiao, Feng
    Pan, Tinsu
    Clark, John W., Jr.
    Mawlawi, Osama R.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2595 - 2598
  • [36] Motion2VecSets: 4D Latent Vector Set Diffusion for Non-rigid Shape Reconstruction and Tracking
    Cao, Wei
    Luo, Chang
    Zhang, Biao
    Niessner, Matthias
    Tang, Jiapeng
    2024 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2024, : 20496 - 20506
  • [37] Investigation of Respiratory Motion Correction with and without Motion Correction of Attenuation Map in Cardiac SPECT/CT in Presence of Non-Rigid Motion, an NCAT study
    Dey, Joyoni
    Segars, W. P.
    Pretorius, P. Hendrik
    King, Michael A.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3237 - 3243
  • [38] Data-driven voluntary body motion detection and non-rigid event-by-event correction for static and dynamic PET
    Lu, Yihuan
    Gallezot, Jean-Dominique
    Naganawa, Mika
    Ren, Silin
    Fontaine, Kathryn
    Wu, Jing
    Onofrey, John A.
    Toyonaga, Takuya
    Boutagy, Nabil
    Mulnix, Tim
    Panini, Vladimir Y.
    Casey, Michael E.
    Carson, Richard E.
    Liu, Chi
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (06):
  • [39] A 3D MR-acquisition scheme for non-rigid bulk motion correction in simultaneous PET-MR
    Christoph Kolbitsch
    Claudia Prieto
    Charalampos Tsoumpas
    Tobias Schaeffter
    EJNMMI Physics, 1 (Suppl 1)
  • [40] Respiratory gated radiotherapy: the 4D radiotherapy
    Giraud, P
    Simon, L
    Saliou, M
    Reboul, F
    Garcia, R
    Carrie, C
    Lerolle, U
    Rosenwald, JC
    Cosset, JM
    BULLETIN DU CANCER, 2005, 92 (01) : 83 - 89