Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients

被引:48
|
作者
Adler, Ghazal [3 ]
Meille, Laurent [3 ]
Rohnean, Adela [3 ]
Sigal-Cinqualbre, Anne [3 ]
Capderou, Andre [2 ]
Paul, Jean-Francois [1 ,3 ]
机构
[1] Ctr Chirurg Marie Lannelongue, Serv Radiol, F-92350 Le Plessis Robinson, France
[2] Ctr Chirurg Marie Lannelongue, Physiol UMR 8162, F-92350 Le Plessis Robinson, France
[3] Ctr Chirurg Marie Lannelongue, Dept Radiol, F-92350 Le Plessis Robinson, France
关键词
Heart rate; Coronary vessels; Computed tomography; Spiral; Cardiac gated imaging techniques; SOURCE COMPUTED-TOMOGRAPHY; IMPROVE IMAGE QUALITY; DIAGNOSTIC-ACCURACY; INITIAL-EXPERIENCE; RATE-VARIABILITY; 1ST EXPERIENCE; CARDIAC CYCLE; ARTERIES; MOTION; OPTIMIZATION;
D O I
10.1007/s00330-009-1642-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Reconstruction of cardiac computed tomography (CT) images is challenging when the heart rate is higher than 65 beats per minute (bpm). The optimal reconstruction time is often found to be at the end-systolic phase, but image quality remains uncertain. Using dual-source (DS) CT and 83-ms temporal resolution, we evaluated the robustness of the temporal window with low motion during the end systole. We studied 41 DSCT in consecutive patients with a heart rate > 65 bpm. Eleven systolic reconstructions were performed every 20 ms between 200 ms and 400 ms of the R-R interval. The end-systolic temporal window (ESTW) was defined as the interval between the first and last selected phases judged adequate for diagnosis. Heart rates varied from 67 to 150 bpm. ESTW was always to be found greater than 100 ms. The mean ESTW was 178 ms (SD: 57 ms), and varied independently of heart rate. All data sets achieved diagnostic quality during the end-systolic phase at a time point between 35 and 50% of the R-R interval. Our data suggest that CT with a temporal window below 100 ms may provide acceptable systolic reconstructions at any heart rate, in a large proportion of patients.
引用
收藏
页码:1118 / 1123
页数:6
相关论文
共 50 条
  • [1] Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients
    Ghazal Adler
    Laurent Meille
    Adela Rohnean
    Anne Sigal-Cinqualbre
    André Capderou
    Jean-François Paul
    European Radiology, 2010, 20 : 1118 - 1123
  • [2] Systolic reconstruction in patients with low heart rate using coronary dual-source CT angiography
    Okada, Munemasa
    Nakashima, Yoshiteru
    Shigemoto, Youko
    Matsunaga, Naofumi
    Miura, Toshiro
    Nao, Tomoko
    Sano, Yuichi
    Narazaki, Akiko
    Kido, Shoji
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : 336 - 341
  • [3] Prospective-triggered sequential dual-source end-systolic coronary CT angiography for patients with atrial fibrillation: A feasibility study
    Srichai, Monvadi B.
    Barreto, Mitya
    Lim, Ruth P.
    Donnino, Robert
    Babb, James S.
    Jacobs, Jill E.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (02) : 102 - 109
  • [4] Dual-source computed tomography coronary angiography in patients with high heart rate
    Fujimura, Tatsuhiro
    Miura, Toshiro
    Nao, Tomoko
    Yoshimura, Masayuki
    Nakashima, Yoshiteru
    Okada, Munemasa
    Okamura, Takayuki
    Yamada, Jutaro
    Ohshita, Chikage
    Wada, Yasuaki
    Matsunaga, Naofumi
    Matsuzaki, Masunori
    Yano, Masafumi
    HEART AND VESSELS, 2014, 29 (04) : 443 - 448
  • [5] Dual-source computed tomography coronary angiography in patients with high heart rate
    Tatsuhiro Fujimura
    Toshiro Miura
    Tomoko Nao
    Masayuki Yoshimura
    Yoshiteru Nakashima
    Munemasa Okada
    Takayuki Okamura
    Jutaro Yamada
    Chikage Ohshita
    Yasuaki Wada
    Naofumi Matsunaga
    Masunori Matsuzaki
    Masafumi Yano
    Heart and Vessels, 2014, 29 : 443 - 448
  • [6] High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates
    Robert Goetti
    Gudrun Feuchtner
    Paul Stolzmann
    Lotus Desbiolles
    Michael Alexander Fischer
    Christoph Karlo
    Stephan Baumueller
    Hans Scheffel
    Hatem Alkadhi
    Sebastian Leschka
    European Radiology, 2010, 20 : 2565 - 2571
  • [7] High-pitch dual-source CT coronary angiography: systolic data acquisition at high heart rates
    Goetti, Robert
    Feuchtner, Gudrun
    Stolzmann, Paul
    Desbiolles, Lotus
    Fischer, Michael Alexander
    Karlo, Christoph
    Baumueller, Stephan
    Scheffel, Hans
    Alkadhi, Hatem
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2010, 20 (11) : 2565 - 2571
  • [8] Dual-source CT coronary angiography: Image quality, mean heart rate, and heart rate variability
    Matt, David
    Scheffel, Hans
    Leschka, Sebastian
    Flohr, Thomas G.
    Marincek, Borut
    Kaufmann, Philipp A.
    Alkadhi, Hatem
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (03) : 567 - 573
  • [9] High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate
    Gordic, Sonja
    Husarik, Daniela B.
    Desbiolles, Lotus
    Leschka, Sebastian
    Frauenfelder, Thomas
    Alkadhi, Hatem
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (06): : 1173 - 1179
  • [10] High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate
    Sonja Gordic
    Daniela B. Husarik
    Lotus Desbiolles
    Sebastian Leschka
    Thomas Frauenfelder
    Hatem Alkadhi
    The International Journal of Cardiovascular Imaging, 2014, 30 : 1173 - 1179