Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients

被引:48
|
作者
Adler, Ghazal [3 ]
Meille, Laurent [3 ]
Rohnean, Adela [3 ]
Sigal-Cinqualbre, Anne [3 ]
Capderou, Andre [2 ]
Paul, Jean-Francois [1 ,3 ]
机构
[1] Ctr Chirurg Marie Lannelongue, Serv Radiol, F-92350 Le Plessis Robinson, France
[2] Ctr Chirurg Marie Lannelongue, Physiol UMR 8162, F-92350 Le Plessis Robinson, France
[3] Ctr Chirurg Marie Lannelongue, Dept Radiol, F-92350 Le Plessis Robinson, France
关键词
Heart rate; Coronary vessels; Computed tomography; Spiral; Cardiac gated imaging techniques; SOURCE COMPUTED-TOMOGRAPHY; IMPROVE IMAGE QUALITY; DIAGNOSTIC-ACCURACY; INITIAL-EXPERIENCE; RATE-VARIABILITY; 1ST EXPERIENCE; CARDIAC CYCLE; ARTERIES; MOTION; OPTIMIZATION;
D O I
10.1007/s00330-009-1642-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Reconstruction of cardiac computed tomography (CT) images is challenging when the heart rate is higher than 65 beats per minute (bpm). The optimal reconstruction time is often found to be at the end-systolic phase, but image quality remains uncertain. Using dual-source (DS) CT and 83-ms temporal resolution, we evaluated the robustness of the temporal window with low motion during the end systole. We studied 41 DSCT in consecutive patients with a heart rate > 65 bpm. Eleven systolic reconstructions were performed every 20 ms between 200 ms and 400 ms of the R-R interval. The end-systolic temporal window (ESTW) was defined as the interval between the first and last selected phases judged adequate for diagnosis. Heart rates varied from 67 to 150 bpm. ESTW was always to be found greater than 100 ms. The mean ESTW was 178 ms (SD: 57 ms), and varied independently of heart rate. All data sets achieved diagnostic quality during the end-systolic phase at a time point between 35 and 50% of the R-R interval. Our data suggest that CT with a temporal window below 100 ms may provide acceptable systolic reconstructions at any heart rate, in a large proportion of patients.
引用
收藏
页码:1118 / 1123
页数:6
相关论文
共 50 条
  • [31] Dual-source coronary CT angiography in patients with high heart rates using a prospectively ECG-triggered axial mode at end-systole
    Hee Yeong Kim
    Ji Won Lee
    Yoo Jin Hong
    Hye-Jeong Lee
    Jin Hur
    Ji Eun Nam
    Byoung Wook Choi
    Young Jin Kim
    The International Journal of Cardiovascular Imaging, 2012, 28 : 101 - 107
  • [32] Detection of coronary artery anomalies by dual-source CT coronary angiography
    Cheng, Z.
    Wang, X.
    Duan, Y.
    Wu, L.
    Wu, D.
    Liang, C.
    Liu, C.
    Xu, Z.
    CLINICAL RADIOLOGY, 2010, 65 (10) : 815 - 822
  • [33] Low-dose adaptive sequential scan for dual-source CT coronary angiography in patients with high heart rate: Comparison with retrospective ECG gating
    Xu, Lei
    Yang, Lin
    Zhang, Zhaoqi
    Li, Yu
    Fan, Zhanming
    Ma, Xiaohai
    Lv, Biao
    Yu, Wei
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (02) : 183 - 187
  • [34] Dual-source CT coronary angiography in patients with atrial fibrillation: Comparison with single-source CT
    Wang, Yining
    Zhang, Zhuhua
    Kong, Lingyan
    Song, Lan
    Merges, Reto D.
    Chen, Jiuhong
    Jin, Zhengyu
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : 434 - 441
  • [35] Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography
    Laspas, Fotios
    Tsantioti, Dimitra
    Roussakis, Arkadios
    Kritikos, Nikolaos
    Efthimiadou, Roxani
    Kehagias, Dimitrios
    Andreou, John
    ACTA RADIOLOGICA, 2011, 52 (03) : 273 - 277
  • [36] Evaluation of coronary stent patency and in-stent restenosis with dual-source CT coronary angiography without heart rate control
    Oncel, Dilek
    Oncel, Guray
    Tastan, Ahmet
    Tamci, Batuhan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) : 56 - 63
  • [37] Influence of heart rate on the diagnostic accuracy of dual-source computed tomography coronary angiography
    Ropers, Ulrike
    Ropers, Dieter
    Pflederer, Tobias
    Anders, Katharina
    Kuettner, Axel
    Stilianakis, Nikolaos I.
    Komatsu, Sei
    Kalender, Willi
    Bautz, Werner
    Daniel, Werner G.
    Achenbach, Stephan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (25) : 2393 - 2398
  • [38] Is dual-source CT coronary angiography ready for the real world?
    Cademartiri, Filippo
    Maffei, Erica
    Mollet, Nico R.
    EUROPEAN HEART JOURNAL, 2008, 29 (06) : 701 - 703
  • [39] Diagnostic accuracy of dual-source CT coronary angiography: The effect of average heart rate, heart rate variability, and calcium score in a clinical perspective
    Zhang, Long-Jiang
    Wu, Sheng-Yong
    Wang, Jing
    Lu, Ying
    Zhang, Zhuo-Li
    Jiang, Shi-Sen
    Zhou, Chang-Sheng
    Lu, Guang-Ming
    ACTA RADIOLOGICA, 2010, 51 (07) : 727 - 740
  • [40] Influence of heart rate and phase of the cardiac cycle on the occurrence of motion artifact in dual-source CT angiography of the coronary arteries
    Achenbach, Stephan
    Manolopoulos, Michael
    Schuhbaeck, Annika
    Ropers, Dieter
    Rixe, Johannes
    Schneider, Christian
    Krombach, Gabriele A.
    Uder, Michael
    Hamm, Christian
    Daniel, Werner G.
    Lell, Michael
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (02) : 91 - 98