Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients

被引:48
|
作者
Adler, Ghazal [3 ]
Meille, Laurent [3 ]
Rohnean, Adela [3 ]
Sigal-Cinqualbre, Anne [3 ]
Capderou, Andre [2 ]
Paul, Jean-Francois [1 ,3 ]
机构
[1] Ctr Chirurg Marie Lannelongue, Serv Radiol, F-92350 Le Plessis Robinson, France
[2] Ctr Chirurg Marie Lannelongue, Physiol UMR 8162, F-92350 Le Plessis Robinson, France
[3] Ctr Chirurg Marie Lannelongue, Dept Radiol, F-92350 Le Plessis Robinson, France
关键词
Heart rate; Coronary vessels; Computed tomography; Spiral; Cardiac gated imaging techniques; SOURCE COMPUTED-TOMOGRAPHY; IMPROVE IMAGE QUALITY; DIAGNOSTIC-ACCURACY; INITIAL-EXPERIENCE; RATE-VARIABILITY; 1ST EXPERIENCE; CARDIAC CYCLE; ARTERIES; MOTION; OPTIMIZATION;
D O I
10.1007/s00330-009-1642-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Reconstruction of cardiac computed tomography (CT) images is challenging when the heart rate is higher than 65 beats per minute (bpm). The optimal reconstruction time is often found to be at the end-systolic phase, but image quality remains uncertain. Using dual-source (DS) CT and 83-ms temporal resolution, we evaluated the robustness of the temporal window with low motion during the end systole. We studied 41 DSCT in consecutive patients with a heart rate > 65 bpm. Eleven systolic reconstructions were performed every 20 ms between 200 ms and 400 ms of the R-R interval. The end-systolic temporal window (ESTW) was defined as the interval between the first and last selected phases judged adequate for diagnosis. Heart rates varied from 67 to 150 bpm. ESTW was always to be found greater than 100 ms. The mean ESTW was 178 ms (SD: 57 ms), and varied independently of heart rate. All data sets achieved diagnostic quality during the end-systolic phase at a time point between 35 and 50% of the R-R interval. Our data suggest that CT with a temporal window below 100 ms may provide acceptable systolic reconstructions at any heart rate, in a large proportion of patients.
引用
收藏
页码:1118 / 1123
页数:6
相关论文
共 50 条
  • [41] Prevalence and morphology of coronary artery ectasia with dual-source CT coronary angiography
    Sebastian Leschka
    Paul Stolzmann
    Hans Scheffel
    Simon Wildermuth
    André Plass
    Michele Genoni
    Borut Marincek
    Hatem Alkadhi
    European Radiology, 2008, 18
  • [42] Coronary artery fistula in adults: evaluation with dual-source CT coronary angiography
    Zhou, K.
    Kong, L.
    Wang, Y.
    Li, S.
    Song, L.
    Wang, Z.
    Wu, W.
    Chen, J.
    Wang, Y.
    Jin, Z.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1049):
  • [43] Diagnostic accuracy of dual-source CT coronary angiography in a population unselected for degree of coronary artery calcification and without heart rate modification
    Lin, C-J.
    Hsu, J. -C.
    Lai, Y. J.
    Wang, K-L
    Lee, J. -Y.
    Li, A. -H.
    Chu, S. -H.
    CLINICAL RADIOLOGY, 2010, 65 (02) : 109 - 117
  • [44] Prevalence and morphology of coronary artery ectasia with dual-source CT coronary angiography
    Leschka, Sebastian
    Stolzmann, Paul
    Scheffel, Hans
    Wildermuth, Simon
    Plass, Andre
    Genoni, Michele
    Marincek, Borut
    Alkadhi, Hatem
    EUROPEAN RADIOLOGY, 2008, 18 (12) : 2776 - 2784
  • [45] Comparison of dual-source ct coronary angiography and conventional coronary angiography for detecting coronary artery disease
    Yi Xu
    Lijun Tang
    Xiaomei Zhu
    Hai Xu
    Jinhua Tang
    Zhijian Yang
    Liansheng Wang
    Dehang Wang
    The International Journal of Cardiovascular Imaging, 2010, 26 : 75 - 81
  • [46] Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control
    Hans Scheffel
    Hatem Alkadhi
    André Plass
    Robert Vachenauer
    Lotus Desbiolles
    Oliver Gaemperli
    Tiziano Schepis
    Thomas Frauenfelder
    Thomas Schertler
    Lars Husmann
    Jürg Grunenfelder
    Michele Genoni
    Philipp A. Kaufmann
    Borut Marincek
    Sebastian Leschka
    European Radiology, 2006, 16 : 2739 - 2747
  • [47] Comparison of dual-source ct coronary angiography and conventional coronary angiography for detecting coronary artery disease
    Xu, Yi
    Tang, Lijun
    Zhu, Xiaomei
    Xu, Hai
    Tang, Jinhua
    Yang, Zhijian
    Wang, Liansheng
    Wang, Dehang
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 : 75 - 81
  • [48] Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control
    Scheffel, Hans
    Alkadhi, Hatem
    Plass, Andre
    Vachenauer, Robert
    Desbiolles, Lotus
    Gaemperli, Oliver
    Schepis, Tiziano
    Frauenfelder, Thomas
    Schertler, Thomas
    Husmann, Lars
    Grunenfelder, Juerg
    Genoni, Michele
    Kaufmann, Philipp A.
    Marincek, Borut
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2006, 16 (12) : 2739 - 2747
  • [49] Diagnostic accuracy of dual-source CT angiography and coronary risk stratification
    Yang, Xia
    Gai, Lu-yue
    Li, Ping
    Chen, Yun-dai
    Li, Tao
    Yang, Li
    VASCULAR HEALTH AND RISK MANAGEMENT, 2010, 6 : 935 - 941
  • [50] Comparison of myocardial bridging by dual-source CT with conventional coronary angiography
    Lu, Guang-Ming
    Zhang, Long-Jiang
    Guo, Hua
    Huang, Wei
    Merges, Reto D.
    CIRCULATION JOURNAL, 2008, 72 (07) : 1079 - 1085