Dual-source CT coronary angiography: Image quality, mean heart rate, and heart rate variability

被引:128
|
作者
Matt, David
Scheffel, Hans
Leschka, Sebastian
Flohr, Thomas G.
Marincek, Borut
Kaufmann, Philipp A.
Alkadhi, Hatem
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Siemens Med Solut, Forchheim, Germany
[3] Univ Zurich Hosp, Ctr Cardiovasc, CH-8091 Zurich, Switzerland
[4] Zurich Ctr Integrat Human Physiol, Zurich, Switzerland
关键词
coronary angiography; dual-source CT; heart rate; image quality;
D O I
10.2214/AJR.07.2078
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate the effect of mean heart rate and heart rate variability on the image quality of dual-source CT coronary angiography. SUBJECTS AND METHODS. Eighty patients underwent dual-source CT coronary angiography. Thirteen data sets were reconstructed in 5% steps from 20-80% of the R-R interval. Heart rate variability was calculated as SD of mean heart rate. Two independent blinded reviewers assessed the image quality of each segment. RESULTS. Mean heart rate was 65.3 +/- 13.9 (SD) beats per minute (bpm) (range, 35-99 bpm) with a variability of 3.4 +/- 4.1 bpm (range, 0.4-17.5 bpm). Image quality was sufficient for diagnosis for 97.8% (1,043/1,066) of arterial segments. No significant correlation was found between mean heart rate and image quality in any segment or any coronary artery. No significant correlation was found between heart rate variability and image quality in any segment, the right coronary artery, or the left anterior descending artery, but there was a significant (p < 0.05) correlation in the left circumflex artery. A significant correlation (p < 0.05) between overall image quality was found for mean and variability of heart rate as shared predictors, the latter having a greater contribution. CONCLUSION. The overall image quality of dual-source CT coronary angiography is sufficient for diagnosis within a wide range of mean heart rates and variability of heart rates. Only heart rates that are both high and variable significantly deteriorate image quality, but the quality remains adequate for diagnosis.
引用
收藏
页码:567 / 573
页数:7
相关论文
共 50 条
  • [1] Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy
    Brodoefel, Harald
    Burgstahler, Christof
    Tsiflikas, Ilias
    Reimann, Anja
    Schroeder, Stephen
    Claussen, Claus D.
    Heuschmid, Martin
    Kopp, Andreas F.
    RADIOLOGY, 2008, 247 (02) : 346 - 355
  • [2] Impact of Heart Rate Frequency and Variability on Radiation Exposure, Image Quality, and Diagnostic Performance in Dual-Source Spiral CT Coronary Angiography
    Weustink, Annick C.
    Neefjes, Lisanne A.
    Kyrzopoulos, Stamatis
    van Straten, Marcel
    Eu, Rick Neoh
    Meijboom, Willem B.
    van Mieghem, Carlos A.
    Capuano, Ermanno
    Dijkshoorn, Marcel L.
    Cademartiri, Filippo
    Boersma, Eric
    de Feyter, Pim J.
    Krestin, Gabriel P.
    Mollet, Nico R.
    RADIOLOGY, 2009, 253 (03) : 672 - 680
  • [3] Dual-source Ct in non-invasive coronary artery angiography: Effect of heart rate, heart rate variability and calcification on image quality and diagnostic accuracy in an unselected patient population
    Burgstahler, Christof
    Brodoefel, Harald
    Reimann, Anja
    Tsiflikas, Ilias
    Heuschmid, Martin
    Uysal, Ines
    Wurster, Diana
    Haeberle, Ellen
    Kopp, Andreas F.
    Schroeder, Stephen
    CIRCULATION, 2007, 116 (16) : 408 - 408
  • [4] Diagnostic accuracy of dual-source CT coronary angiography: The effect of average heart rate, heart rate variability, and calcium score in a clinical perspective
    Zhang, Long-Jiang
    Wu, Sheng-Yong
    Wang, Jing
    Lu, Ying
    Zhang, Zhuo-Li
    Jiang, Shi-Sen
    Zhou, Chang-Sheng
    Lu, Guang-Ming
    ACTA RADIOLOGICA, 2010, 51 (07) : 727 - 740
  • [5] Diagnostic Quality of Dual-Source Coronary CT Examinations Performed Without Heart Rate Control: Importance of Obesity and Heart Rate on Image Quality
    Zimmerman, Stefan L.
    Kral, Brian G.
    Fishman, Elliot K.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (06) : 949 - 955
  • [6] 256-slice CT coronary angiography in atrial fibrillation: The impact of mean heart rate and heart rate variability on image quality
    Chen, Liang-Kuang
    Hsu, Shih-Ming
    Mok, Greta S. P.
    Law, Wei-Yip
    Lu, Kun-Mu
    Yang, Ching-Ching
    Wu, Tung-Hsin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S153 - S157
  • [7] Optimal electrocardiographic pulsing windows and heart rate: Effect on image quality and radiation exposure at dual-source coronary CT angiography
    Weustink, Annick C.
    Mollet, Nico R.
    Pugliese, Francesca
    Meijboom, Willem B.
    Nieman, Koen
    Heijenbrok-Kal, Majanka H.
    Flohr, Thomas G.
    Neefjes, Lisanne A. E.
    Cademartiri, Filippo
    de Feyter, Pim J.
    Krestin, Gabriel P.
    RADIOLOGY, 2008, 248 (03) : 792 - 798
  • [8] Dual-source CT coronary angiography without heart rate or rhythm control in comparison with conventional coronary angiography
    Fang, Xiang Ming
    Chen, Hong Wei
    Hu, Xiao Yun
    Bao, Jian
    Chen, Yin
    Yang, Zhen Yu
    Buckley, Orla
    Wu, Xiao Qing
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (03): : 323 - 331
  • [9] Dual-source CT coronary angiography without heart rate or rhythm control in comparison with conventional coronary angiography
    Xiang Ming Fang
    Hong Wei Chen
    Xiao Yun Hu
    Jian Bao
    Yin Chen
    Zhen Yu Yang
    Orla Buckley
    Xiao Qing Wu
    The International Journal of Cardiovascular Imaging, 2010, 26 : 323 - 331
  • [10] Relationship between Heart Rate and Optimal Reconstruction Phase in Dual-source CT Coronary Angiography
    Horii, Yosuke
    Yoshimura, Norihiko
    Hori, Yoshiro
    Takano, Toru
    Inagawa, Shoichi
    Akazawa, Kohei
    Aoyama, Hidefumi
    ACADEMIC RADIOLOGY, 2011, 18 (06) : 726 - 730