Liquid Chromatography-Isotope Dilution-Mass Spectrometry as a New Basis for the Reference Measurement Procedure for Hemoglobin A1c Determination

被引:45
|
作者
Kaiser, Patricia [1 ]
Akerboom, Theodorus [2 ]
Ohlendorf, Ruediger [3 ]
Reinauer, Hans [1 ]
机构
[1] INSTAND eV, Reference Measurement Lab, D-40223 Dusseldorf, Germany
[2] Univ Dusseldorf, Inst Clin Chem & Lab Diagnost, Dusseldorf, Germany
[3] Phys Tech Bundesanstalt, D-3300 Braunschweig, Germany
关键词
PROTEIN QUANTIFICATION; STANDARDIZATION; HBA(1C);
D O I
10.1373/clinchem.2009.139477
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Standardization of hemoglobin (Hb)A(1c) measurements is a process of considerable interest for quality assurance in diabetes management. To contribute to continuous quality improvement and fulfillment of the requirements for reference measurement procedures according to the standards of the International Organization for Standardization, we developed a calibration system of highest metrological order using isotope dilution-mass spectrometry with a reference material. METHOD: Samples were prepared by enzymatic cleavage based on the IFCC reference measurement procedure for LC-MS analysis. After digestion the samples were spiked with [D7]-labeled glycated and nonglycated hexapeptides as internal standards for quantification. LC-MS analysis was performed by using a C12 reversed-phase column and a gradient of acetonitrile/H2O containing 0.1% formic acid. RESULTS: Calibration systems for HbA(1c) determination based on liquid chromatography-isotope dilution-mass spectrometry (LC-ID-MS) and on the IFCC reference measurement procedure were compared. A linear regression analysis demonstrated a correlation of r(2) = 1.00 between the 2 different calibration systems. Mean deviation was 5.5% for the calibration and 3.3% for hemolysate samples, with a mean expanded uncertainty of 4.9%. CONCLUSIONS: This LC-ID-MS procedure allows the current IFCC reference measurement procedure for HbA(1c) to be raised to a higher order of accuracy. (C) 2010 American Association for Clinical Chemistry
引用
收藏
页码:750 / 754
页数:5
相关论文
共 50 条
  • [31] Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry
    Susan S.-C. Tai
    Bei Xu
    Michael J. Welch
    Karen W. Phinney
    Analytical and Bioanalytical Chemistry, 2007, 388 : 1087 - 1094
  • [32] Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry
    Tai, Susan S. -C.
    Xu, Bei
    Welch, Michael J.
    Phinney, Karen W.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (5-6) : 1087 - 1094
  • [33] REFERENCE METHODS FOR THE DETERMINATION OF STEROIDS AND URIC-ACID BY THE USE OF ISOTOPE DILUTION-MASS SPECTROMETRY
    SIEKMANN, L
    ROHLE, G
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 324 (3-4): : 208 - 209
  • [34] COMPARISON OF GAS-LIQUID-CHROMATOGRAPHY, MASS FRAGMENTOGRAPHY, AND ISOTOPE DILUTION-MASS SPECTROMETRY FOR DETERMINATION OF PENTOBARBITAL IN HUMAN-PLASMA
    SUSANTO, F
    HUMFELD, S
    REINAUER, H
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 323 (02): : 168 - 172
  • [35] Quantification of hemoglobin A1c by off-line HPLC separation and liquid chromatography-tandem mass spectrometry: a modification of the IFCC reference measurement procedure
    Zhang, Tianjiao
    Zhang, Chuanbao
    Chen, Wenxiang
    Zhao, Haijian
    Zhang, Jiangtao
    Zhou, Weiyan
    Zeng, Jie
    Wang, Jing
    Wang, Donghuan
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (04) : 569 - 576
  • [36] Development of a liquid chromatography-isotope dilution mass spectrometry method for quantification of fentanyl in human plasma
    Lu, Chuan
    Jia, Jing-ying
    Gui, Yu-zhou
    Liu, Gang-yi
    Shi, Xiao-jin
    Li, Shui-jun
    Yu, Chen
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (07) : 711 - 716
  • [37] Development and evaluation of a candidate reference measurement procedure for the determination of progesterone in human serum using isotope-dilution liquid chromatography/tandem mass spectrometry
    Tai, Susan S. -C.
    Xu, Bei
    Welch, Michael J.
    ANALYTICAL CHEMISTRY, 2006, 78 (18) : 6628 - 6633
  • [38] Liquid chromatography-isotope dilution tandem mass spectrometry method for the measurement of urea in human serum and assignment of reference values to external quality assessment samples
    Yong, Sharon
    Liu, Hong
    Wong, Lingkai
    Teo, Hui Ling
    Chen, Yizhao
    Liu, Qinde
    Teo, Tang Lin
    Lee, Tong Kooi
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 414 : 87 - 93
  • [39] Measurement of urea in human serum by isotope dilution mass spectrometry: A reference procedure
    Kessler, A
    Siekmann, L
    CLINICAL CHEMISTRY, 1999, 45 (09) : 1523 - 1529
  • [40] DETERMINATION OF HEMOGLOBIN A1C BY LIQUID-CHROMATOGRAPHY
    PANULAONTTO, R
    GUSTAFSSON, S
    CLINICAL CHEMISTRY, 1988, 34 (01) : 210 - 210