Liquid Chromatography-Isotope Dilution-Mass Spectrometry as a New Basis for the Reference Measurement Procedure for Hemoglobin A1c Determination

被引:45
|
作者
Kaiser, Patricia [1 ]
Akerboom, Theodorus [2 ]
Ohlendorf, Ruediger [3 ]
Reinauer, Hans [1 ]
机构
[1] INSTAND eV, Reference Measurement Lab, D-40223 Dusseldorf, Germany
[2] Univ Dusseldorf, Inst Clin Chem & Lab Diagnost, Dusseldorf, Germany
[3] Phys Tech Bundesanstalt, D-3300 Braunschweig, Germany
关键词
PROTEIN QUANTIFICATION; STANDARDIZATION; HBA(1C);
D O I
10.1373/clinchem.2009.139477
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Standardization of hemoglobin (Hb)A(1c) measurements is a process of considerable interest for quality assurance in diabetes management. To contribute to continuous quality improvement and fulfillment of the requirements for reference measurement procedures according to the standards of the International Organization for Standardization, we developed a calibration system of highest metrological order using isotope dilution-mass spectrometry with a reference material. METHOD: Samples were prepared by enzymatic cleavage based on the IFCC reference measurement procedure for LC-MS analysis. After digestion the samples were spiked with [D7]-labeled glycated and nonglycated hexapeptides as internal standards for quantification. LC-MS analysis was performed by using a C12 reversed-phase column and a gradient of acetonitrile/H2O containing 0.1% formic acid. RESULTS: Calibration systems for HbA(1c) determination based on liquid chromatography-isotope dilution-mass spectrometry (LC-ID-MS) and on the IFCC reference measurement procedure were compared. A linear regression analysis demonstrated a correlation of r(2) = 1.00 between the 2 different calibration systems. Mean deviation was 5.5% for the calibration and 3.3% for hemolysate samples, with a mean expanded uncertainty of 4.9%. CONCLUSIONS: This LC-ID-MS procedure allows the current IFCC reference measurement procedure for HbA(1c) to be raised to a higher order of accuracy. (C) 2010 American Association for Clinical Chemistry
引用
收藏
页码:750 / 754
页数:5
相关论文
共 50 条
  • [21] New Concepts for the Determination of Oxidation Efficiencies in Liquid Chromatography-Isotope Ratio Mass Spectrometry
    Koester, Daniel
    Villalobos, Irene M. Sanchez
    Jochmann, Maik A.
    Brand, Willi A.
    Schmidt, Torsten C.
    ANALYTICAL CHEMISTRY, 2019, 91 (08) : 5067 - 5073
  • [22] An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma
    Zhang, Qiaoxuan
    Han, Liqiao
    Zheng, Songbai
    Ouyang, Fen
    Wu, Xiaobin
    Yan, Jun
    Zhan, Min
    Ke, Peifeng
    Zhuang, Junhua
    Huang, Xianzhang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (17) : 4471 - 4481
  • [23] An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma
    Qiaoxuan Zhang
    Liqiao Han
    Songbai Zheng
    Fen Ouyang
    Xiaobin Wu
    Jun Yan
    Min Zhan
    Peifeng Ke
    Junhua Zhuang
    Xianzhang Huang
    Analytical and Bioanalytical Chemistry, 2021, 413 : 4471 - 4481
  • [24] A comparison of enzymatic digestion for the quantitation of an oligonucleotide by liquid chromatography-isotope dilution mass spectrometry
    Donald, CE
    Stokes, P
    O'Connor, G
    Woolford, AJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 817 (02): : 173 - 182
  • [25] Modifications to the NIST reference measurement procedure (RMP) for the determination of serum glucose by isotope dilution gas chromatography/mass spectrometry
    Jocelyn L. Prendergast
    Lorna T. Sniegoski
    Michael J. Welch
    Karen W. Phinney
    Analytical and Bioanalytical Chemistry, 2010, 397 : 1779 - 1785
  • [26] The determination of lysergide (LSD) in urine by high-performance liquid chromatography-isotope dilution mass spectrometry (IDMS)
    White, SA
    Kidd, AS
    Webb, KS
    JOURNAL OF FORENSIC SCIENCES, 1999, 44 (02) : 375 - 379
  • [27] DETERMINATION OF URINE CREATINE, CREATININE. GUANIDINOACETATE, AND ARGININE BY LIQUID CHROMATOGRAPHY-ISOTOPE DILUTION TANDEM MASS SPECTROMETRY
    Yazdanpanah, M.
    Adeli, K.
    vonBoth, I.
    Schulze, A.
    Kyriakopoulou, G. L.
    MOLECULAR GENETICS AND METABOLISM, 2009, 98 (1-2) : 134 - 134
  • [28] Modifications to the NIST reference measurement procedure (RMP) for the determination of serum glucose by isotope dilution gas chromatography/mass spectrometry
    Prendergast, Jocelyn L.
    Sniegoski, Lorna T.
    Welch, Michael J.
    Phinney, Karen W.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (05) : 1779 - 1785
  • [29] Determination of Cortisol in Human Serum Using Ultrasonic Extraction Coupled with Liquid Chromatography-Isotope Dilution Mass Spectrometry
    Zhou Jian
    Wang Min
    Tang Xiao-Yan
    Mao Xue-Fei
    Dai Xin-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (09) : 1439 - 1443
  • [30] Simultaneous determination of itraconazole and hydroxyitraconazole in human plasma by liquid chromatography-isotope dilution tandem mass spectrometry method
    Jia, Jing-ying
    Lu, Chuan
    Liu, Gang-yi
    Zhang, Meng-qi
    Liu, Yan-mei
    Wang, Wei
    Weng, Li-ping
    Li, Shui-jun
    Yu, Chen
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (06) : 648 - 654