Audit feasibility for geometric distortion in magnetic resonance imaging for radiotherapy

被引:9
|
作者
Alzahrani, Meshal [1 ,2 ]
Broadbent, David A. [3 ]
Chuter, Robert [4 ,5 ]
Al-Qaisieh, Bashar [3 ]
Jackson, Steven [4 ]
Michael, Hutton [4 ]
Johnstone, Robert, I [6 ]
Shah, Simon [6 ]
Wetscherek, Andreas [7 ,8 ]
Chick, H. Joan [7 ,8 ]
Wyatt, Jonathan J. [9 ,10 ]
McCallum, Hazel Mhairi [9 ,10 ]
Speight, Richard [3 ]
机构
[1] King Abdulaziz Univ, Fac Appl Med Sci, Dept Diagnost Radiol, Jeddah, Saudi Arabia
[2] Univ Leeds, Leeds Inst Cardiovasc & Metab Med, Biomed Imaging Sci Dept, Leeds, W Yorkshire, England
[3] Leeds Teaching Hosp NHS Trust, Dept Med Phys & Engn, Leeds, W Yorkshire, England
[4] Christie NHS Fdn Trust, Christie Med Phys & Engn CMPE, Manchester, Lancs, England
[5] Univ Manchester, Fac Biol Med & Hlth, Div Canc Sci, Manchester, Lancs, England
[6] Guys & St Thomas NHS Fdn Trust, London, England
[7] Inst Canc Res, Joint Dept Phys, London, England
[8] Royal Marsden NHS Fdn Trust, London, England
[9] Newcastle Upon Tyne Hosp NHS Fdn Trust, Northern Ctr Canc Care, Newcastle Upon Tyne, Tyne & Wear, England
[10] Newcastle Univ, Ctr Canc, Newcastle Upon Tyne, Tyne & Wear, England
关键词
Magnetic resonance imaging; Geometric distortion; Radiotherapy; Quality assurance; Audit; RADIATION-THERAPY; MRI; PRECISION; ACCURACY; IMPACT;
D O I
10.1016/j.phro.2020.07.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Magnetic Resonance Imaging (MRI) is increasingly being used in radiotherapy (RT). However, geometric distortions are a known challenge of using MRI in RT. The aim of this study was to demonstrate feasibility of a national audit of MRI geometric distortions. This was achieved by assessing large field of view (FOV) MRI distortions on a number of scanners used clinically for RT. Materials and methods: MRI scans of a large FOV MRI geometric distortion phantom were acquired on 11 MRI scanners that are used clinically for RT in the UK. The mean and maximum distortions and variance between scanners were reported at different distances from the isocentre. Results: For a small FOV representing a brain (100-150 mm from isocentre) all distortions were < 2 mm except for the maximum distortion of one scanner. For a large FOV representing a head and neck/pelvis (200-250 mm from isocentre) mean distortions were < 2 mm except for one scanner, maximum distortions were > 10 mm in some cases. The variance between scanners was low and was found to increase with distance from isocentre. Conclusions: This study demonstrated feasibility of the technique to be repeated in a country wide geometric distortion audit of all MRI scanners used clinically for RT. Recommendations were made for performing such an audit and how to derive acceptable limits of distortion in such an audit.
引用
收藏
页码:80 / 84
页数:5
相关论文
共 50 条
  • [41] ON THE PROBLEM OF GEOMETRIC DISTORTION IN MAGNETIC-RESONANCE IMAGES FOR STEREOTAXIC NEUROSURGERY
    MICHIELS, J
    BOSMANS, H
    PELGRIMS, P
    VANDERMEULEN, D
    GYBELS, J
    MARCHAL, G
    SUETENS, P
    MAGNETIC RESONANCE IMAGING, 1994, 12 (05) : 749 - 765
  • [42] An audit of preoperative magnetic resonance imaging staging of the breast
    Bagnall, M.
    Turnbull, A. E.
    BREAST CANCER RESEARCH, 2006, 8 (Suppl 1) : S9 - S9
  • [43] Compensation of geometric distortion effects on intraoperative magnetic resonance imaging for enhanced visualization in image-guided neurosurgery
    Archip, Neculai
    Clatz, Olivier
    Whalen, Stephen
    DiMaio, Simon P.
    Black, Peter M.
    Jolesz, Ferenc A.
    Golby, Alexandra
    Warfield, Simon K.
    NEUROSURGERY, 2008, 63 (03) : 209 - 215
  • [44] Quality assurance measurements of geometric accuracy for magnetic resonance imaging-based radiotherapy treatment planning
    Ranta, Iiro
    Kemppainen, Reko
    Keyrilainen, Jani
    Suilamo, Sami
    Heikkinen, Samuli
    Kapanen, Mika
    Saunavaara, Jani
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 62 : 47 - 52
  • [45] Geometric accuracy of magnetic resonance imaging of the mandibular nerve
    Eggers, G
    Rieker, M
    Fiebach, J
    Kress, B
    Dickhaus, H
    Hassfeld, S
    DENTOMAXILLOFACIAL RADIOLOGY, 2005, 34 (05) : 285 - 291
  • [46] Feasibility of magnetic resonance guided radiotherapy for the treatment of bladder cancer
    Hunt, A.
    Hanson, I.
    Dunlop, A.
    Barnes, H.
    Bower, L.
    Chick, J.
    Cruickshank, C.
    Hall, E.
    Herbert, T.
    Lawes, R.
    McQuaid, D.
    McNair, H.
    Mitchell, A.
    Mohajer, J.
    Morgan, T.
    Oelfke, U.
    Smith, G.
    Nill, S.
    Huddart, R.
    Hafeez, S.
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2020, 25 : 46 - 51
  • [47] Role of magnetic resonance imaging and magnetic resonance spectroscopic imaging before and after radiotherapy for prostate cancer
    Westphalen, Antonio C.
    Mckenna, David A.
    Kurhanewicz, John
    Coakley, Fergus V.
    JOURNAL OF ENDOUROLOGY, 2008, 22 (04) : 789 - 794
  • [48] Geometric distortion in magnetic resonance imaging systems assessed using an open-source plugin for scientific image analysis
    Aoyama T.
    Shimizu H.
    Shimizu I.
    Teramoto A.
    Kaneda N.
    Nakamura K.
    Nakamura M.
    Kodaira T.
    Radiological Physics and Technology, 2018, 11 (4) : 467 - 472
  • [49] A proposed scheme for comprehensive characterization of the measured geometric distortion in magnetic resonance imaging using a three-dimensional phantom
    Wang, DM
    Doddrell, DM
    MEDICAL PHYSICS, 2004, 31 (08) : 2212 - 2218
  • [50] Compensation of geometric distortion effects on intraoperative magnetic resonance imaging for enhanced visualization in image-guided neurosurgery - Comments
    Nimsky, Christopher
    Lozano, Andres M.
    Bradley, William G., Jr.
    NEUROSURGERY, 2008, 63 (03) : 215 - 216