A proposed scheme for comprehensive characterization of the measured geometric distortion in magnetic resonance imaging using a three-dimensional phantom

被引:20
|
作者
Wang, DM [1 ]
Doddrell, DM [1 ]
机构
[1] Univ Queensland, Ctr Magnet Resonance, Brisbane, Qld 4072, Australia
关键词
geometric distortion; 3-D phantom; comprehensive assessment; characterization; MRI; quality assurance;
D O I
10.1118/1.1767051
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, a 3-dimensional phantom that can provide a comprehensive, accurate and complete measurement of the geometric distortion in MRI has been developed. In this paper, a scheme for characterizing the measured geometric distortion using the 3-D phantom is described. In the proposed scheme, a number of quantitative measures are developed and used to characterize the geometric distortion. These measures encompass the overall and spatial aspects of the geometric distortion. Two specific types of volume of interest, rectangular parallelepipeds (including cubes) and spheres are considered in the proposed scheme. As an illustration, characterization of the geometric distortion in a Siemens 1.5T Sonata MRI system using the proposed scheme is presented. As shown, the proposed scheme provides a comprehensive assessment of the geometric distortion. The scheme can be potentially used as a standard procedure for the assessment of geometric distortion in MRI. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:2212 / 2218
页数:7
相关论文
共 50 条
  • [1] Design and construction of a customizable phantom for the characterization of the three-dimensional magnetic resonance imaging geometric distortion
    Torfeh, Tarraf
    Hammoud, Rabih
    Paloor, Satheesh
    Arunachalam, Yoganathan
    Aouadi, Souha
    Al-Hammadi, Noora
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (12): : 149 - 157
  • [2] A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging
    Wang, DM
    Doddrell, DM
    Cowin, G
    MAGNETIC RESONANCE IMAGING, 2004, 22 (04) : 529 - 542
  • [3] Impact Assessment of Systemic Geometric Distortion in 1.5T Magnetic Resonance Imaging Simulation through Three-dimensional Geometric Distortion Phantom on Dosimetric Accuracy for Magnetic Resonance Imaging-only Prostate Treatment Planning
    Chaknam, Korawig
    Worapruekjaru, Ladawan
    Suphaphong, Sithiphong
    Stansook, Nualjun
    Sodkokkruad, Prapa
    Asavaphatiboon, Sawwanee
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) : 356 - 362
  • [4] Three-dimensional analytical magnetic resonance Imaging phantom in the Fourier domain
    Koay, Cheng Guan
    Sarls, Joelle E.
    Ozarslan, Evren
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (02) : 430 - 436
  • [5] Reproducibility of geometric distortion in magnetic resonance imaging based on phantom studies
    Mizowaki, T
    Nagata, Y
    Okajima, K
    Kokubo, M
    Negoro, Y
    Araki, N
    Hiraoka, M
    RADIOTHERAPY AND ONCOLOGY, 2000, 57 (02) : 237 - 242
  • [6] Genome wide association studies on three-dimensional aortic geometric indices measured with magnetic resonance imaging
    Beeche, C.
    Dib, M. J.
    Azzo, J. D.
    Maynard, H.
    Salman, O.
    Witschey, W.
    Chirinos, J.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [7] Anterior talofibular ligament footprint dimension measured using three-dimensional magnetic resonance imaging
    Kono, Kenta
    Yamaguchi, Satoshi
    Kimura, Seiji
    Mikami, Yukio
    Kitsukawa, Kaoru
    Matsumoto, Koji
    Edama, Mutsuaki
    Shiko, Yuki
    Horii, Manato
    Sasho, Takahisa
    Ohtori, Seiji
    SKELETAL RADIOLOGY, 2024, : 937 - 945
  • [8] Three-dimensional lumbar spine postures measured by magnetic resonance imaging reconstruction
    Cargill, Sara C.
    Pearcy, Mark
    Barry, Mark Darrell
    SPINE, 2007, 32 (11) : 1242 - 1248
  • [9] An Anthropomorphic Head Phantom Prototype for the Measurement of Geometric Distortion in Magnetic Resonance Imaging System
    Shurche, Sadegh
    Sooteh, Mohammad Yousefi
    Iranian Journal of Medical Physics, 2024, 21 (01) : 53 - 63
  • [10] Three-dimensional magnetic resonance imaging for groundwater
    Legchenko, A.
    Descloitres, M.
    Vincent, C.
    Guyard, H.
    Garambois, S.
    Chalikakis, K.
    Ezersky, M.
    NEW JOURNAL OF PHYSICS, 2011, 13