Cross-calibration of interferometric SAR data

被引:17
|
作者
Dall, J [1 ]
机构
[1] Tech Univ Denmark, Orsted DTU, DK-2800 Kongens Lyngby, Denmark
关键词
D O I
10.1049/ip-rsn:20030448
中图分类号
TN [电子技术、通信技术];
学科分类号
0809 ;
摘要
Generation of digital elevation models from interferometric synthetic aperture radar (SAR) data is a well established technique. Achieving a high geometric fidelity calls for a calibration accounting for inaccurate navigation data and system parameters as well as system imperfections. Fully automated calibration techniques are preferable, especially for operational mapping. The author presents one such technique, called cross-calibration. Though developed for single-pass interferometry, it may be applicable to multi-pass interferometry, too. Cross-calibration requires stability during mapping, but not necessarily from map to map. It is based on natural distributed targets for which no a priori knowledge is needed. In particular, no DEM is required as in calibration techniques based on dedicated calibration scenes. To achieve absolute calibration, i.e. elimination of a constant elevation offset, a single ground control point is often needed. The paper presents the principles and mathematics of the cross-calibration technique and illustrates its successful application to EMISAR data.
引用
收藏
页码:177 / 183
页数:7
相关论文
共 50 条
  • [31] Online Cross-Calibration of Camera and LIDAR
    Blaga, Bianca-Cerasela-Zelia
    Nedevschi, Sergiu
    2017 13TH IEEE INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTER COMMUNICATION AND PROCESSING (ICCP), 2017, : 295 - 301
  • [32] Cross-calibration of cluster mass observables
    Cunha, Carlos
    PHYSICAL REVIEW D, 2009, 79 (06):
  • [33] Technical Note: CT calibration for proton treatment planning by cross-calibration with proton CT data
    Farace, Paolo
    Tommasino, Francesco
    Righetto, Roberto
    Fracchiolla, Francesco
    Scaringella, Monica
    Bruzzi, Mara
    Civinini, Carlo
    MEDICAL PHYSICS, 2021, 48 (03) : 1349 - 1355
  • [34] CALIBRATION OF AIRBORNE INTERFEROMETRIC SAR DATA BY EXTERNAL DEM WITHOUT ARTIFICIAL CALIBRATORS
    Yun, Ye
    Zeng, Qiming
    Jiao, Jian
    Liang, Cunren
    Wang, Qing
    Zhou, Xiao
    Yan, Dapeng
    2012 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2012, : 4501 - 4504
  • [35] Cross-Calibration for Data Fusion of EO-1/Hyperion and Terra/ASTER
    Yokoya, Naoto
    Mayumi, Norimasa
    Iwasaki, Akira
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2013, 6 (02) : 419 - 426
  • [36] Cross-Calibration of the HSI Sensor Reflective Solar Bands Using Hyperion Data
    Gao, Hailiang
    Jupp, David
    Qin, Yi
    Gu, Xingfa
    Yu, Tao
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2015, 53 (07): : 4127 - 4137
  • [37] Cross-calibration of reflective bands of major moderate resolution remotely sensed data
    Zhong, B.
    Yang, A.
    Wu, S.
    Li, J.
    Liu, S.
    Liu, Q.
    REMOTE SENSING OF ENVIRONMENT, 2018, 204 : 412 - 423
  • [38] Peripheral quantitative CT of the forearm: scanner cross-calibration using patient data
    Grampp, S
    Nather, A
    Rintelen, B
    Henk, C
    Resch-Holeczke, A
    Imhof, H
    Resch, H
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (867): : 275 - 277
  • [39] INTERFEROMETRIC SAR CALIBRATION WITH AREA CALIBRATION SITE OF SAME HEIGHT
    Zhang, Wei
    Xiang, Maosheng
    Wu, Yirong
    2009 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-5, 2009, : 2934 - 2937
  • [40] Cross-calibration of two small footprint sensors
    GustafsonBold, CL
    Thome, KJ
    IGARSS '96 - 1996 INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM: REMOTE SENSING FOR A SUSTAINABLE FUTURE, VOLS I - IV, 1996, : 1283 - 1285