Peripheral quantitative CT of the forearm: scanner cross-calibration using patient data

被引:4
|
作者
Grampp, S
Nather, A
Rintelen, B
Henk, C
Resch-Holeczke, A
Imhof, H
Resch, H
机构
[1] Univ Vienna, Klin Radiodiagnost, Osteol MR, A-1090 Vienna, Austria
[2] Krankenhaus Barmherzigen Schwestern, Innere Med Abt, A-1060 Vienna, Austria
[3] Kaiser Franz Josef Spital, Innere Med Abt, A-1100 Vienna, Austria
[4] Univ Vienna, Klin Strahlentherapie, A-1090 Vienna, Austria
来源
BRITISH JOURNAL OF RADIOLOGY | 2000年 / 73卷 / 867期
关键词
D O I
10.1259/bjr.73.867.10817043
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Bone density measurements by peripheral quantitative CT (pQCT) of the distal radius in 87 women (age 38.4+/-12.3 years) were obtained on a both a Stratec XCT 900 and an updated version XCT 1400. Axial area, and total and trabecular bone mineral density (BMD) results from both scanners were compared for all patients using linear regression analysis. To achieve scanner calibration we used the intercept and slope of the patients' correlations. The correlations of the patients' values were good for area (r=0.83) as well as total BMD (r=0.90) and excellent for trabecular BMD (r=0.97). The cross-calibration approach in our study provided compatibility of pQCT for trabecular and total ROIs, the clinically mostly utilized volumes of measurement.
引用
收藏
页码:275 / 277
页数:3
相关论文
共 50 条
  • [1] CROSS-CALIBRATION OF BMD MEASUREMENT BETWEEN A DEDICATED PQCT SCANNER AND QCT OF PERIPHERAL SITES USING A CLINICAL WHOLE-BODY HELICAL CT SCANNER
    Bodeen, G.
    Mahboubi, S.
    Brown, J. K.
    Zemel, B. S.
    Brett, A.
    Leonard, M. B.
    OSTEOPOROSIS INTERNATIONAL, 2014, 25 : S347 - S347
  • [2] CROSS-CALIBRATION OF BMD MEASUREMENT BETWEEN A DEDICATED PQCT SCANNER AND QCT OF PERIPHERAL SITES USING A CLINICAL WHOLE-BODY HELICAL CT SCANNER
    Bodeen, Gabriel
    Mahboubi, Soroosh
    Brown, J. Keenan
    Zemel, Babette S.
    Brett, Alan
    Leonard, Mary B.
    OSTEOPOROSIS INTERNATIONAL, 2014, 25 : S507 - S508
  • [3] Characterization of the INFN proton CT scanner for cross-calibration of x-ray CT
    Fogazzi, Elena
    Trevisan, Diego
    Farace, Paolo
    Righetto, Roberto
    Rit, Simon
    Scaringella, Monica
    Bruzzi, Mara
    Tommasino, Francesco
    Civinini, Carlo
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (12):
  • [4] Technical Note: CT calibration for proton treatment planning by cross-calibration with proton CT data
    Farace, Paolo
    Tommasino, Francesco
    Righetto, Roberto
    Fracchiolla, Francesco
    Scaringella, Monica
    Bruzzi, Mara
    Civinini, Carlo
    MEDICAL PHYSICS, 2021, 48 (03) : 1349 - 1355
  • [5] A constancy test to monitor cross-calibration factors for a small animal SPECT-CT scanner
    Vines, Douglass
    Green, David
    Keller, Harald
    Breen, Stephen
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [6] Cross-calibration of interferometric SAR data
    Dall, J
    IEE PROCEEDINGS-RADAR SONAR AND NAVIGATION, 2003, 150 (03) : 177 - 183
  • [7] Static and mobile DXA scanner in-vivo cross-calibration study
    Griffin, J. G. L.
    Knapp, K. M.
    Pearce, G.
    RADIOGRAPHY, 2013, 19 (01) : 7 - 10
  • [8] SCATTEROMETER CROSS-CALIBRATION USING ANTARCTICA AS A CALIBRATION TARGET
    Porter, Nathan
    Long, David G.
    IGARSS 2023 - 2023 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, 2023, : 4282 - 4285
  • [9] USING SPACEBORNE HYPERSPECTRAL DATA FOR SPECTRAL CROSS-CALIBRATION OF MULTISPECTRAL SENSORS
    Bachmann, Martin
    Mueller, Tassilo
    2015 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2015, : 2813 - 2815
  • [10] CROSS-CALIBRATION OF FOREARM BONE-MINERAL MEASUREMENTS - PRELIMINARY-RESULTS
    HAGIWARA, S
    ENGELKE, K
    FAULKNER, KG
    GLUER, CC
    HAYASHICLARK, C
    GENANT, HK
    JOURNAL OF BONE AND MINERAL RESEARCH, 1992, 7 : S185 - S185