Peripheral quantitative CT of the forearm: scanner cross-calibration using patient data

被引:4
|
作者
Grampp, S
Nather, A
Rintelen, B
Henk, C
Resch-Holeczke, A
Imhof, H
Resch, H
机构
[1] Univ Vienna, Klin Radiodiagnost, Osteol MR, A-1090 Vienna, Austria
[2] Krankenhaus Barmherzigen Schwestern, Innere Med Abt, A-1060 Vienna, Austria
[3] Kaiser Franz Josef Spital, Innere Med Abt, A-1100 Vienna, Austria
[4] Univ Vienna, Klin Strahlentherapie, A-1090 Vienna, Austria
来源
BRITISH JOURNAL OF RADIOLOGY | 2000年 / 73卷 / 867期
关键词
D O I
10.1259/bjr.73.867.10817043
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Bone density measurements by peripheral quantitative CT (pQCT) of the distal radius in 87 women (age 38.4+/-12.3 years) were obtained on a both a Stratec XCT 900 and an updated version XCT 1400. Axial area, and total and trabecular bone mineral density (BMD) results from both scanners were compared for all patients using linear regression analysis. To achieve scanner calibration we used the intercept and slope of the patients' correlations. The correlations of the patients' values were good for area (r=0.83) as well as total BMD (r=0.90) and excellent for trabecular BMD (r=0.97). The cross-calibration approach in our study provided compatibility of pQCT for trabecular and total ROIs, the clinically mostly utilized volumes of measurement.
引用
收藏
页码:275 / 277
页数:3
相关论文
共 50 条
  • [21] CROSS-CALIBRATION OF LIQUID AND SOLID QCT CALIBRATION STANDARDS - CORRECTIONS TO THE UCSF NORMATIVE DATA
    FAULKNER, KG
    GLUER, CC
    GRAMPP, S
    GENANT, HK
    OSTEOPOROSIS INTERNATIONAL, 1993, 3 (01) : 36 - 42
  • [22] Extended Cross-Calibration Analysis Using Data from the Landsat 8 and 9 Underfly Event
    Gross, Garrison
    Helder, Dennis
    Leigh, Larry
    REMOTE SENSING, 2023, 15 (07)
  • [23] The improvement of cross-calibration of IIM data and band selection for FeO inversion
    Wang Chao
    Wu YunZhao
    Shi RunHe
    Gao Wei
    SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2013, 56 (11) : 2216 - 2225
  • [24] CROSS-CALIBRATION OF FULL POLARIMETRIC RIX AND TERRASAR-X DATA
    Gimeno Martinez, N.
    Gomez Miguel, B.
    Lopez Pescador, A.
    Cifuentes Revenga, P.
    Nieto Borge, J. C.
    2012 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2012, : 5864 - 5867
  • [25] The improvement of cross-calibration of IIM data and band selection for FeO inversion
    Chao Wang
    YunZhao Wu
    RunHe Shi
    Wei Gao
    Science China Physics, Mechanics and Astronomy, 2013, 56 : 2216 - 2225
  • [26] The improvement of cross-calibration of IIM data and band selection for FeO inversion
    WANG Chao
    WU YunZhao
    SHI RunHe
    GAO Wei
    Science China(Physics,Mechanics & Astronomy), 2013, (11) : 2216 - 2225
  • [27] Cross-Calibration for Data Fusion of EO-1/Hyperion and Terra/ASTER
    Yokoya, Naoto
    Mayumi, Norimasa
    Iwasaki, Akira
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2013, 6 (02) : 419 - 426
  • [28] Cross-calibration of reflective bands of major moderate resolution remotely sensed data
    Zhong, B.
    Yang, A.
    Wu, S.
    Li, J.
    Liu, S.
    Liu, Q.
    REMOTE SENSING OF ENVIRONMENT, 2018, 204 : 412 - 423
  • [29] Radiometric Cross-Calibration of Hyperspectral Microsatellites Using Spectral Homogeneity Factor
    Zhang, Siqing
    Rao, Keyi
    Wu, Zhaocong
    Wang, Shaoju
    Dai, Zhixiong
    Fang, Ruixin
    Wang, Kexin
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2025, 18 : 2342 - 2354
  • [30] A DXA BODY COMPOSITION CROSS-CALIBRATION EXPERIENCE USING PHANTOMS AND HUMANS
    Libber, J.
    Krueger, D.
    Sanfilippo, J.
    Yu, H. J.
    Miller, C.
    Binkley, N.