A neutron track etch detector for electron linear accelerators in radiotherapy

被引:10
|
作者
Vukovic, Branko [1 ]
Faj, Dario [2 ]
Poje, Marina [1 ]
Varga, Maja [1 ]
Radolic, Vanja [1 ]
Miklavcic, Igor [1 ]
Ivkovic, Ana [2 ]
Planinic, Josip [1 ]
机构
[1] Univ Osijek, Dept Phys, HR-31000 Osijek, Croatia
[2] Clin Hosp Osijek, Osijek, Croatia
关键词
electron linear accelerator; photoneutron; track etch detector; neutron dose equivalent; SPECTRA;
D O I
10.2478/v10019-010-0003-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. Electron linear accelerators in medical radiotherapy have replaced cobalt and caesium sources of radiation. However, medical accelerators with photon energies over 10 MeV generate undesired fast neutron contamination in a therapeutic X-ray photon beam. Photons with energies above 10 MeV can interact with the atomic nucleus of a high-Z material, of which the target and the head of an accelerator consist, and lead to the neutron ejection. Results and conclusions. Our neutron dosimeter, composed of the LR-115 track etch detector and boron foil BN-1 converter, was calibrated on thermal neutrons generated in the nuclear reactor of the Josef Stefan Institute (Slovenia), and applied to dosimetry of undesirable neutrons in photon radiotherapy by the linear accelerator 15 MV Siemens Mevatron. Having considered a high dependence of a cross-section between neutron and boron on neutron energy, and broad neutron spectrum in a photon beam, as well as outside the entrance door to maze of the Mevatron, we developed a method for determining the effective neutron detector response. A neutron dose rate in the photon beam was measured to be 1.96 Sv/h. Outside the Mevatron room the neutron dose rate was 0.62 mu Sv/h. PACS: 87.52. Ga; 87.53.St; 29.40.Wk.
引用
收藏
页码:62 / 66
页数:5
相关论文
共 50 条
  • [21] Neutron production associated with radiotherapy linear accelerators using intensity modulated radiation therapy mode
    Waller, EJ
    HEALTH PHYSICS, 2003, 85 (05): : S75 - S77
  • [22] Gamma dosimetry with CR-39 etch track detector
    Matiullah
    Dogar, AH
    Ahmad, N
    Amin, M
    Kudo, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1999, 38 (6A): : 3761 - 3762
  • [24] Gamma dosimetry with CR-39 etch track detector
    Matiullah
    Dogar, Ashiq Hussain
    Ahmad, Nasir
    Amin, Masood
    Kudo, Katsuhisa
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1999, 38 (6 A): : 3761 - 3762
  • [25] Evaluation of CdZnTe as neutron detector around medical accelerators
    Martin-Martin, A.
    Iniguez, M. P.
    Luke, P. N.
    Barquero, R.
    Lorente, A.
    Morchon, J.
    Gallego, E.
    Quincoces, G.
    Marti-Climent, J. M.
    RADIATION PROTECTION DOSIMETRY, 2009, 133 (04) : 193 - 199
  • [26] Effectiveness of customised neutron shielding in the maze of radiotherapy accelerators
    Waller, EJ
    Jamieson, TJ
    Cole, D
    Cousins, T
    Jammal, RB
    RADIATION PROTECTION DOSIMETRY, 2003, 107 (04) : 233 - 238
  • [27] Evaluation of air photoactivation at linear accelerators for radiotherapy
    Tana, Luigi
    Ciolini, Riccardo
    Ciuffardi, Eva
    Romei, Chiara
    d'Errico, Francesco
    JOURNAL OF RADIOLOGICAL PROTECTION, 2015, 35 (02) : 239 - 248
  • [28] MEASUREMENTS OF HEAD SCATTER FOR RADIOTHERAPY LINEAR ACCELERATORS
    KASE, KR
    SVENSSON, GK
    MEDICAL PHYSICS, 1985, 12 (04) : 542 - 542
  • [29] Versatility is the key for the future of radiotherapy linear accelerators
    Madle, Neil
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2007, 6 (01) : 59 - 61
  • [30] Evaluation of the sensitivity for the track-etch neutron radiography method
    Pugliesi, R
    Pereira, MAS
    RADIATION MEASUREMENTS, 2003, 37 (02) : 109 - 112