Gamma dosimetry with CR-39 etch track detector

被引:3
|
作者
Matiullah
Dogar, AH
Ahmad, N
Amin, M
Kudo, K
机构
[1] Pakistan Inst Engn & Appl Sci, Islamabad, Pakistan
[2] Electrotech Lab, Tsukuba, Ibaraki 3058568, Japan
关键词
food preservation; high gamma doses; etching characteristics; bulk etching rate; mass change method;
D O I
10.1143/JJAP.38.3761
中图分类号
O59 [应用物理学];
学科分类号
摘要
To preserve and improve the safety of food for commercial purposes, it is exposed to high gamma-ray doses. The gammaray doses used for this purpose range from 0.15 kGy to 510 kGy. At such high doses, the etching characteristics of CR-39 are severely affected. This property, therefore, can be used to develop a CR-39-based gamma dosimeter. In this context, systematic studies were carried out and the bulk etching rate was determined as a function of gamma-ray dose using different methods.
引用
收藏
页码:3761 / 3762
页数:2
相关论文
共 50 条
  • [1] Gamma dosimetry with CR-39 etch track detector
    Matiullah
    Dogar, Ashiq Hussain
    Ahmad, Nasir
    Amin, Masood
    Kudo, Katsuhisa
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 1999, 38 (6 A): : 3761 - 3762
  • [2] Proton beam dosimetry by CR-39 track-etched detector
    Ghergherehchi, M.
    Afarideh, H.
    Maraghe, M. Ghanadi
    Mohammadzadeh, A.
    Esmaeilnezhad, M.
    IRANIAN JOURNAL OF RADIATION RESEARCH, 2008, 6 (03): : 121 - 127
  • [4] Digital image analysis of etch pit formation in CR-39 track detector
    Sato, Fuminobu
    Kuchimaru, Takahiro
    Kato, Yushi
    Iida, Toshiyuki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (01) : 269 - 272
  • [5] Digital image analysis of etch pit formation in CR-39 track detector
    Division of Electric, Electronic and Information Engineering, Osaka University, Suita, Osaka 565-0871, Japan
    Japanese Journal of Applied Physics, 2008, 47 (01): : 269 - 272
  • [6] A REVIEW OF THE USE OF CR-39 TRACK DETECTOR IN PERSONNEL NEUTRON DOSIMETRY AND SPECTROMETRY
    MATIULLAH
    AHMAD, N
    DURRANI, SA
    KUDO, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 51 (01): : 76 - 84
  • [7] FAST-NEUTRON DOSIMETRY USING A CR-39 PLASTIC TRACK DETECTOR
    KHAN, HA
    KHAN, NA
    NUCLEAR INSTRUMENTS & METHODS, 1980, 178 (2-3): : 491 - 497
  • [8] Depth-dependence of the bulk etch rate of gamma-ray irradiated CR-39 track detector
    Yamauchi, T
    Ichijo, H
    Oda, K
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 85 - 89
  • [9] Proton detection with CR-39 track detector
    Dajko, G
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 359 - 362
  • [10] CR-39 Track Detector as a Photonic Crystal
    Eissa, M. F.
    Aly, Arafa H.
    JOURNAL OF COMPUTATIONAL AND THEORETICAL NANOSCIENCE, 2013, 10 (06) : 1527 - 1531