Gamma dosimetry with CR-39 etch track detector

被引:3
|
作者
Matiullah
Dogar, AH
Ahmad, N
Amin, M
Kudo, K
机构
[1] Pakistan Inst Engn & Appl Sci, Islamabad, Pakistan
[2] Electrotech Lab, Tsukuba, Ibaraki 3058568, Japan
关键词
food preservation; high gamma doses; etching characteristics; bulk etching rate; mass change method;
D O I
10.1143/JJAP.38.3761
中图分类号
O59 [应用物理学];
学科分类号
摘要
To preserve and improve the safety of food for commercial purposes, it is exposed to high gamma-ray doses. The gammaray doses used for this purpose range from 0.15 kGy to 510 kGy. At such high doses, the etching characteristics of CR-39 are severely affected. This property, therefore, can be used to develop a CR-39-based gamma dosimeter. In this context, systematic studies were carried out and the bulk etching rate was determined as a function of gamma-ray dose using different methods.
引用
收藏
页码:3761 / 3762
页数:2
相关论文
共 50 条
  • [31] A STUDY OF BULK-ETCH RATES AND TRACK-ETCH RATES IN CR-39
    GREEN, PF
    RAMLI, AG
    ALNAJJAR, SAR
    ABUJARAD, F
    DURRANI, SA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 203 (1-3): : 551 - 559
  • [32] Interrelated temperature dependence of bulk etch rate and track length saturation time in CR-39 detector
    Azooz, A. A.
    Al-Jubbori, M. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 316 : 171 - 175
  • [33] Improved track-etch neutron radiography using CR-39
    Pereira, M. A. Stanojev
    Marques, J. G.
    Pugliesi, R.
    Santos, J. P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 764 : 310 - 316
  • [34] THE ETCH-INDUCTION TIME TI AND ETCH-CRITICAL TIME TC IN CR-39 PLASTIC NUCLEAR TRACK DETECTOR
    HAFEZ, AF
    HUNYADI, I
    KOTB, MA
    ISOTOPENPRAXIS, 1991, 27 (04): : 214 - 218
  • [35] Mass resolution for iron isotopes in CR-39 track detector
    Kodaira, S
    Hasebe, N
    Doke, T
    Kitagawa, A
    Kitamura, H
    Sato, S
    Uchihori, Y
    Yasuda, N
    Ogura, K
    Tawara, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2004, 43 (9A): : 6358 - 6363
  • [37] APPLICATIONS OF CR-39 NUCLEAR TRACK DETECTOR IN MEDICINE AND TECHNOLOGY
    HENSHAW, DL
    PHYSICS IN TECHNOLOGY, 1982, 13 (06): : 266 - &
  • [38] Calibration of CR-39 solid state nuclear track detector
    P. Wanabongse
    B. Sola
    J. Jamsangtong
    S. Rattanabussayaporn
    Indian Journal of Physics, 2009, 83 : 833 - 837
  • [39] Calibration study on the triton response of CR-39 track detector
    Yamauchi, T
    Oda, K
    Tanabe, S
    Matsumoto, H
    Miyake, H
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 191 - 196
  • [40] OXYGEN EFFECT ON THE ETCH RATE IN CR-39 PLASTIC DETECTOR.
    Heins, T.
    Enge, W.
    1600, (12): : 1 - 6