Calibration study on the triton response of CR-39 track detector

被引:14
|
作者
Yamauchi, T [1 ]
Oda, K [1 ]
Tanabe, S [1 ]
Matsumoto, H [1 ]
Miyake, H [1 ]
机构
[1] Kobe Univ Mercantile Marine, Dept Nucl Engn, Higashinada Ku, Kobe, Hyogo 658, Japan
关键词
triton; CR-39; detector; growth curve; etch-pit radius; etch-pit length; etch-pit profile;
D O I
10.1016/S1350-4487(97)00066-8
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Triton response of the CR-39 track detector has been studied at energy ranges below 2.7 MeV. Triton irradiation was made both on the top and the well polished side surface of the CR-39 sample sheets, using Li-6(n,t)He-4 reaction in a thermal neutron field. At large residual ranges more than 10 mu m, fine results of etch rate ratio were obtained by analysing the growth curves of etch-pit radius on the top surface. But the response at near the track end-point could not be obtained well in this method, as a result of the missing track effect. Clearly resolved response at short residual ranges was attained by means of the shape analysis of the etch-pit profile observed on the side surface.
引用
收藏
页码:191 / 196
页数:6
相关论文
共 50 条
  • [1] Calibration of CR-39 solid state nuclear track detector
    P. Wanabongse
    B. Sola
    J. Jamsangtong
    S. Rattanabussayaporn
    Indian Journal of Physics, 2009, 83 : 833 - 837
  • [2] Calibration of solid state nuclear track detector CR-39
    Ren, GX
    Jing, GR
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (06): : 596 - 598
  • [3] Calibration of CR-39 solid state nuclear track detector
    Wanabongse, P.
    Sola, B.
    Jamsangtong, J.
    Rattanabussayaporn, S.
    INDIAN JOURNAL OF PHYSICS, 2009, 83 (06) : 833 - 837
  • [4] RESPONSE FUNCTION OF THE PLASTIC TRACK DETECTOR CR-39
    LUCK, HB
    RADIATION EFFECTS LETTERS, 1982, 67 (05): : 141 - 146
  • [5] CALIBRATION OF RADON DIFFUSION CUP EQUIPPED WITH CR-39 TRACK DETECTOR
    AVRAMOVIC, I
    BENDERAC, R
    VELICKOVIC, D
    STANKOVIC, S
    KOVACEVIC, M
    RADIATION MEASUREMENTS, 1995, 25 (1-4) : 607 - 608
  • [6] Calibration of solid state nuclear track detector CR-39 with monoenergetic protons
    Duan Xiao-Jiao
    Tan Zhi-Xin
    Lan Xiao-Fei
    Huang Yong-Sheng
    Guo Shi-Lun
    Yang Da-Wei
    Tang Xiu-Zhang
    Wang Nai-Yan
    ACTA PHYSICA SINICA, 2010, 59 (05) : 3147 - 3153
  • [7] Proton detection with CR-39 track detector
    Dajko, G
    RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) : 359 - 362
  • [8] CR-39 Track Detector as a Photonic Crystal
    Eissa, M. F.
    Aly, Arafa H.
    JOURNAL OF COMPUTATIONAL AND THEORETICAL NANOSCIENCE, 2013, 10 (06) : 1527 - 1531
  • [9] THE EFFECT OF ENVIRONMENTAL TREATMENT ON THE TRACK RESPONSE OF THE CR-39 PLASTIC DETECTOR
    ABOUELKHIER, AAA
    GABER, M
    MAHMOUD, SA
    ELSHAFEY, E
    MATERIALS LETTERS, 1995, 24 (1-3) : 41 - 45
  • [10] Response of nuclear track detector CR-39 to low energy muons
    Thomas, H. S. P.
    Deas, R. M.
    Kirkham, L. N.
    Dodd, P. M.
    Zemaityte, E.
    Hillier, A. D.
    Neely, D.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2021, 63 (12)