A neutron track etch detector for electron linear accelerators in radiotherapy

被引:10
|
作者
Vukovic, Branko [1 ]
Faj, Dario [2 ]
Poje, Marina [1 ]
Varga, Maja [1 ]
Radolic, Vanja [1 ]
Miklavcic, Igor [1 ]
Ivkovic, Ana [2 ]
Planinic, Josip [1 ]
机构
[1] Univ Osijek, Dept Phys, HR-31000 Osijek, Croatia
[2] Clin Hosp Osijek, Osijek, Croatia
关键词
electron linear accelerator; photoneutron; track etch detector; neutron dose equivalent; SPECTRA;
D O I
10.2478/v10019-010-0003-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. Electron linear accelerators in medical radiotherapy have replaced cobalt and caesium sources of radiation. However, medical accelerators with photon energies over 10 MeV generate undesired fast neutron contamination in a therapeutic X-ray photon beam. Photons with energies above 10 MeV can interact with the atomic nucleus of a high-Z material, of which the target and the head of an accelerator consist, and lead to the neutron ejection. Results and conclusions. Our neutron dosimeter, composed of the LR-115 track etch detector and boron foil BN-1 converter, was calibrated on thermal neutrons generated in the nuclear reactor of the Josef Stefan Institute (Slovenia), and applied to dosimetry of undesirable neutrons in photon radiotherapy by the linear accelerator 15 MV Siemens Mevatron. Having considered a high dependence of a cross-section between neutron and boron on neutron energy, and broad neutron spectrum in a photon beam, as well as outside the entrance door to maze of the Mevatron, we developed a method for determining the effective neutron detector response. A neutron dose rate in the photon beam was measured to be 1.96 Sv/h. Outside the Mevatron room the neutron dose rate was 0.62 mu Sv/h. PACS: 87.52. Ga; 87.53.St; 29.40.Wk.
引用
收藏
页码:62 / 66
页数:5
相关论文
共 50 条
  • [41] NEUTRON-PRODUCTION BY ELECTRON-ACCELERATORS
    GOZANI, T
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1974, 19 (OCT27): : 63 - 63
  • [42] Linear electron accelerators for industry and medicine
    Vorogushin, MF
    Gavrish, YN
    Demskii, MI
    Nikolaev, VM
    Myasnikov, YV
    Petrunin, VI
    Ogorodnikov, SA
    ATOMIC ENERGY, 1999, 87 (02) : 596 - 600
  • [43] Applications of Electron Linear Induction Accelerators
    Westenskow, Glen
    Chen, Yu-Jiuan
    INDUCTION ACCELERATORS, 2011, : 165 - 183
  • [44] Parallel track-etch detector arrangement for radon measurement in soil
    Turek, K
    Bednar, J
    Neznal, M
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 751 - 754
  • [45] ELECTRON LINEAR ACCELERATORS FOR FAST-NEUTRON DATA MEASUREMENTS IN SUPPORT OF FUSION ENERGY APPLICATIONS
    BOCKHOFF, KH
    CARLSON, AD
    WASSON, OA
    HARVEY, JA
    LARSON, DC
    NUCLEAR SCIENCE AND ENGINEERING, 1990, 106 (02) : 192 - 207
  • [46] A CERENKOV DETECTOR TO DETERMINE THE ENERGY IN ELECTRON-ACCELERATORS
    MARTENS, H
    SEEGER, W
    STRAHLENTHERAPIE, 1980, 156 (10) : 697 - 702
  • [47] THE DEVELOPMENT OF LINEAR ACCELERATORS AND SYNCHROTRONS FOR RADIOTHERAPY AND FOR RESEARCH IN PHYSICS
    COCKCROFT, J
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1949, 96 (102): : 296 - 303
  • [48] Track-etch neutron dosemeter with flat response and spectrometric properties
    Luszik-Bhadra, M.
    Alberts, W.G.
    Dietz, E.
    Guldbakke, S.
    Nuclear Tracks and Radiation Measurements, 1991, 19 (1-4): : 485 - 488
  • [49] IMPROVED SENSITIVITY AND CONTRAST, TRACK ETCH THERMAL-NEUTRON RADIOGRAPHY
    BERGER, H
    LAPINSKI, NP
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1972, 15 (01): : 123 - &
  • [50] WORKLOAD AND USE FACTOR OF MEDICAL LINEAR ACCELERATORS IN RADIOTHERAPY
    KRON, T
    ALDRICH, B
    JOVANOVIC, K
    HOWLETT, S
    HAMILTON, C
    HEALTH PHYSICS, 1995, 69 (06): : 971 - 975