Calibration and application of radiometer for low-temperature infrared radiation source

被引:0
|
作者
Shi, Qingfeng [1 ,2 ]
Gao, Yanze [1 ,2 ]
Li, Zhuo [1 ,2 ]
Shi, Rui [1 ,2 ]
机构
[1] Beijing Inst Technol, Sch Opt & Photon, Beijing 100081, Peoples R China
[2] Beijing Key Lab Precis Optoelect Measurement Inst, Beijing 100081, Peoples R China
基金
中国博士后科学基金;
关键词
radiation calibration; low-temperature infrared radiation; infrared radiometer;
D O I
10.1117/12.2606178
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In response to the current increasing demand for calibration of low-temperature infrared radiation sources with a large dynamic range, this paper studies a calibration method for low-temperature infrared radiation sources with a temperature range of 100-450K. The improvement of the signal-to-noise ratio of the input signal by related detection techniques is analyzed. Developed a radiation calibration device, also called a radiometer, analyzed the calibration and measurement process of the radiometer, and established a corresponding mathematical model. The experimental results show that the minimum radiation intensity that can be measured by the radiometer is 2.47x10(-12) W, and the response rate of the radiometer is 102878.38 V/W. Use the calibrated radiometer to measure the target simulator. The source and contribution of the uncertainty of the radiometer in the measurement process are analyzed.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Spectral Calibration for the Large Aperture Infrared Radiometer
    Ye Zhao
    Wan Zhi
    Li Xian-sheng
    Ren Jian-wei
    Liu Hong-xing
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (07) : 1994 - 1998
  • [42] Calibration of advanced visible and near infrared radiometer
    Shimada, M
    Oaku, H
    Oguma, H
    Green, RO
    Miyachi, Y
    Shimoda, H
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1999, 37 (03): : 1472 - 1483
  • [43] Thermal infrared radiometer calibration and experimental measurements
    Wei JiAn
    Wang Difeng
    Gong Fang
    Yan Bai
    He Xianqiang
    2015 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTICAL SENSORS AND APPLICATIONS, 2015, 9620
  • [44] Calibration of advanced visible and near infrared radiometer
    Shimada, Masanobu
    Oaku, Hiromi
    Oguma, Hiroyuki
    Green, Robert O.
    Miyachi, Yuji
    Shimoda, Haruhisa
    IEEE Transactions on Geoscience and Remote Sensing, 1999, 37 (3 II): : 1472 - 1483
  • [45] A LOW TEMPERATURE PRECISION INFRARED SOURCE
    TITUS, JS
    SCHMIDT, R
    JANSSON, RM
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1968, 58 (11) : 1553 - &
  • [46] A Low-temperature Blackbody Source from-30 °C to 30 °C for Industrial Calibration
    Knazovicka, L.
    Strnad, R.
    TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 8, 2013, 1552 : 678 - 681
  • [47] LOW-TEMPERATURE RADIATION POLYMERIZATION OF ACROLEINE
    FINKELSH.EI
    ABKIN, AD
    DOKLADY AKADEMII NAUK SSSR, 1965, 161 (05): : 1098 - &
  • [48] LOW-TEMPERATURE RECEIVER OF THERMAL RADIATION
    MALNEV, AF
    KREMENCHUGSKY, LS
    OPTIKA I SPEKTROSKOPIYA, 1960, 9 (04): : 530 - 531
  • [49] RADIATION CURED LOW-TEMPERATURE COATINGS
    WU, XS
    YAN, F
    DIRLIKOV, SK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1989, 197 : 25 - PMSE
  • [50] DESIGN, CONSTRUCTION, AND CALIBRATION OF AN INFRARED TEMPERATURE PROFILE RADIOMETER (ITPR) FOR NIMBUS-E
    BOWEN, GS
    ISA TRANSACTIONS, 1974, 13 (02) : 101 - 119